Gijs van Praagh

Mr. Gijs van Praagh

University Medical Center Groningen (UMCG)
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
PNPieter H. Nienhuis
Pieter H. Nienhuis
Gijs van PraaghGijs van Praagh
Gijs van Praagh
AGAndor W. J. M. Glaudemans
Andor W. J. M. Glaudemans
EBElisabeth Brouwer
Elisabeth Brouwer
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Imaging is becoming increasingly important for the diagnosis of large vessel vasculitis (LVV). Atherosclerosis may be difficult to distinguish from LVV on imaging as both are inflammatory conditions of the arterial wall. Differentiating atherosclerosis from LVV is important to enable optimal diagnosis, risk assessment, and tailored treatment at a patient level. This paper reviews the current evidence of ultrasound (US), 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography (FDG-PET), computed tomography (CT), and magnetic resonance imaging (MRI) to distinguish LVV from atherosclerosis. In this review, we identified a total of eight studies comparing LVV patients to atherosclerosis patients using imaging—four US studies, two FDG-PET studies, and two CT studies. The included studies mostly applied different methodologies and outcome parameters to investigate vessel wall inflammation. This review reports the currently available evidence and provides recommendations on further methodological standardization methods and future directions for research.

27 March 2024 in Seminars in Nuclear Medicine
Verified
Journal Article
Open access
KGKornelis S.M van der Geest
Kornelis S.M van der Geest
OGOlivier Gheysens
Olivier Gheysens
LGLars Christian Gormsen
Lars Christian Gormsen
Andor W. J. M. GlaudemansAndor W. J. M. Glaudemans
Andor W. J. M. Glaudemans
CTCharalampos Tsoumpas
Charalampos Tsoumpas
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Systemic vasculitides are autoimmune diseases characterized by inflammation of blood vessels. They are categorized based on the size of the preferentially affected blood vessels: large-, medium-, and small-vessel vasculitides. The main forms of large-vessel vasculitis include giant cell arteritis (GCA) and Takayasu arteritis (TAK). Depending on the location of the affected vessels, various imaging modalities can be employed for diagnosis of large vessel vasculitis: ultrasonography (US), magnetic resonance angiography (MRA), computed tomography angiography (CTA), and [18F]-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT). These imaging tools offer complementary information about vascular changes occurring in vasculitis. Recent advances in PET imaging in large vessel vasculitis include the introduction of digital long axial field-of-view PET/CT, dedicated acquisition, quantitative methodologies, and the availability of novel radiopharmaceuticals. This review aims to provide an update on the current status of PET imaging in large vessel vasculitis and to share the latest developments on imaging vasculitides.

1 May 2021 in Medical Physics
Verified
Journal Article
Open access
PDF file
Gijs van PraaghGijs van Praagh
Gijs van Praagh
NWNiels R. van der Werf
Niels R. van der Werf
JWJia Wang
Jia Wang
FOFasco van Ommen
Fasco van Ommen
KPKeris Poelhekken
Keris Poelhekken
MWMartin J. Willemink
Martin J. Willemink
Objective: Coronary artery calcium (CAC) score is a strong predictor for future adverse cardiovascular events. Anthropomorphic phantoms are often used for CAC studies on computed tomography (CT) to allow for evaluation or variation of scanning or reconstruction parameters within or across scanners against a reference standard. This often results in large number of datasets. Manual assessment of these large datasets is time consuming and cumbersome. Therefore, this study aimed to develop and validate a fully automated, open‐source quantification method (FQM) for coronary calcium in a standardized phantom.Materials and Methods: A standard, commercially available anthropomorphic thorax phantom was used with an insert containing nine calcifications with different sizes and densities. To simulate two different patient sizes, an extension ring was used. Image data were acquired with four state‐of‐the‐art CT systems using routine CAC scoring acquisition protocols. For interscan variability, each acquisition was repeated five times with small translations and/or rotations. Vendor‐specific CAC scores (Agatston, volume, and mass) were calculated as reference scores using vendor‐specific software. Both the international standard CAC quantification methods as well as vendor‐specific adjustments were implemented in FQM. Reference and FQM scores were compared using Bland‐Altman analysis, intraclass correlation coefficients, risk reclassifications, and Cohen’s kappa. Also, robustness of FQM was assessed using varied acquisitions and reconstruction settings and validation on a dynamic phantom. Further, image quality metrics were implemented: noise power spectrum, task transfer function, and contrast‐ and signal‐to‐noise ratio among others. Results were validated using imQuest software.Results: Three parameters in CAC scoring methods varied among the different vendor‐specific software packages: the Hounsfield unit (HU) threshold, the minimum area used to designate a group of voxels as calcium, and the usage of isotropic voxels for the volume score. The FQM was in high agreement with vendor‐specific scores and ICC’s (median [95% CI]) were excellent (1.000 [0.999‐1.000] to 1.000 [1.000‐1.000]). An excellent interplatform reliability of κ = 0.969 and κ = 0.973 was found. TTF results gave a maximum deviation of 3.8% and NPS results were comparable to imQuest.Conclusions: We developed a fully automated, open‐source, robust method to quantify CAC on CT scans in a commercially available phantom. Also, the automated algorithm contains image quality assessment for fast comparison of differences in acquisition and reconstruction parameters.

9 February 2023 in Biomolecules
Verified
Journal Article
Open access
PDF file
LDLisa M. Duff
Lisa M. Duff
ASAndrew Scarsbrook
Andrew Scarsbrook
NRNishant Ravikumar
Nishant Ravikumar
RFRussell Frood
Russell Frood
Gijs van PraaghGijs van Praagh
Gijs van Praagh
CTCharalampos Tsoumpas
Charalampos Tsoumpas
The aim of this study was to develop and validate an automated pipeline that could assist the diagnosis of active aortitis using radiomic imaging biomarkers derived from [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET-CT) images. The aorta was automatically segmented by convolutional neural network (CNN) on FDG PET-CT of aortitis and control patients. The FDG PET-CT dataset was split into training (43 aortitis:21 control), test (12 aortitis:5 control) and validation (24 aortitis:14 control) cohorts. Radiomic features (RF), including SUV metrics, were extracted from the segmented data and harmonized. Three radiomic fingerprints were constructed: A—RFs with high diagnostic utility removing highly correlated RFs; B used principal component analysis (PCA); C—Random Forest intrinsic feature selection. The diagnostic utility was evaluated with accuracy and area under the receiver operating characteristic curve (AUC). Several RFs and Fingerprints had high AUC values (AUC > 0.8), confirmed by balanced accuracy, across training, test and external validation datasets. Good diagnostic performance achieved across several multi-centre datasets suggests that a radiomic pipeline can be generalizable. These findings could be used to build an automated clinical decision tool to facilitate objective and standardized assessment regardless of observer experience.

14 July 2021 in Investigative Radiology
Verified
Journal Article
Open access
Gijs van PraaghGijs van Praagh
Gijs van Praagh
JWJia Wang
Jia Wang
NWNiels Roderik van der Werf
Niels Roderik van der Werf
MGMarcel Greuter
Marcel Greuter
DMDomenico Mastrodicasa
Domenico Mastrodicasa
MWMartin J. Willemink
Martin J. Willemink
Objectives: Although the Agatston score is a commonly used quantification method, rescan reproducibility is suboptimal, and different CT scanners result in different scores. In 2007, McCollough et al (Radiology 2007;243:527–538) proposed a standard for coronary artery calcium quantification. Advancements in CT technology over the last decade, however, allow for improved acquisition and reconstruction methods. This study aims to investigate the feasibility of a reproducible reduced dose alternative of the standardized approach for coronary artery calcium quantification on state-of-the-art CT systems from 4 major vendors. Materials and Methods: An anthropomorphic phantom containing 9 calcifications and 2 extension rings were used. Images were acquired with 4 state-of-the-art CT systems using routine protocols and a variety of tube voltages (80–120 kV), tube currents (100% to 25% dose levels), slice thicknesses (3/2.5 and 1/1.25 mm), and reconstruction techniques (filtered back projection and iterative reconstruction). Every protocol was scanned 5 times after repositioning the phantom to assess reproducibility. Calcifications were quantified as Agatston scores. Results: Reducing tube voltage to 100 kV, dose to 75%, and slice thickness to 1 or 1.25 mm combined with higher iterative reconstruction levels resulted in an on average 36% lower intrascanner variability (interquartile range) compared with the standard 120 kV protocol. Interscanner variability per phantom size decreased by 34% on average. With the standard protocol, on average, 6.2 ± 0.4 calcifications were detected, whereas 7.0 ± 0.4 were detected with the proposed protocol. Pairwise comparisons of Agatston scores between scanners within the same phantom size demonstrated 3 significantly different comparisons at the standard protocol (P < 0.05), whereas no significantly different comparisons arose at the proposed protocol (P > 0.05). Conclusions: On state-of-the-art CT systems of 4 different vendors, a 25% reduced dose, thin-slice calcium scoring protocol led to improved intrascanner and interscanner reproducibility and increased detectability of small and low-density calcifications in this phantom. The protocol should be extensively validated before clinical use, but it could potentially improve clinical interscanner/interinstitutional reproducibility and enable more consistent risk assessment and treatment strategies.

24 October 2023 in British Journal of Radiology
Verified
Journal Article
Open access
HTHendrea Sanne Aletta Tingen
Hendrea Sanne Aletta Tingen
Gijs van PraaghGijs van Praagh
Gijs van Praagh
PNPieter H. Nienhuis
Pieter H. Nienhuis
ATAlwin Tubben
Alwin Tubben
NRNick van Rijsewijk
Nick van Rijsewijk
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Cardiovascular diseases (CVD) are the leading cause of death worldwide and have an increasing impact on society. Precision medicine, in which optimal care is identified for an individual or a group of individuals rather than for the average population, might provide significant health benefits for this patient group and decrease CVD morbidity and mortality. Molecular imaging provides the opportunity to assess biological processes in individuals in addition to anatomical context provided by other imaging modalities and could prove to be essential in the implementation of precision medicine in CVD. New developments in single-photon emission computed tomography (SPECT) and positron emission tomography (PET) systems, combined with rapid innovations in promising and specific radiopharmaceuticals, provide an impressive improvement of diagnostic accuracy and therapy evaluation. This may result in improved health outcomes in CVD patients, thereby reducing societal impact. Furthermore, recent technical advances have led to new possibilities for accurate image quantification, dynamic imaging, and quantification of radiotracer kinetics. This potentially allows for better evaluation of disease activity over time and treatment response monitoring. However, the clinical implementation of these new methods has been slow. This review describes the recent advances in molecular imaging and the clinical value of quantitative PET and SPECT in various fields in cardiovascular molecular imaging, such as atherosclerosis, myocardial perfusion and ischemia, infiltrative cardiomyopathies, systemic vascular diseases, and infectious cardiovascular diseases. Moreover, the challenges that need to be overcome to achieve clinical translation are addressed, and future directions are provided.