Arnhold Lohse

Mr. Arnhold Lohse

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ALArnhold Lohse
Arnhold Lohse
PPPhilip von Platen
Philip von Platen
CBCarl-Friedrich Benner
Carl-Friedrich Benner
MDMatthias Manfred Deininger
Matthias Manfred Deininger
TSTeresa Gertrud Seemann
Teresa Gertrud Seemann
MWMarian Walter
Marian Walter
Diaphragm atrophy is a common side effect of mechanical ventilation and results in prolonged weaning. Electric phrenic nerve stimulation presents a possibility to avoid diaphragm atrophy by keeping the diaphragm conditioned in sedated patients. There is a need of further investigation on how to set stimulation parameters to achieve sufficient ventilation. A prototype system is presented with a systematic evaluation for stimulation pattern adjustments. The main indicator for efficient stimulation was the tidal volume. The evaluation was performed in two pig models. As a major finding, the results for biphasic pulses were more consistent than for alternating pulses. The tidal volume increased for a range of pulse frequency and pulse width until reaching a plateau at 80–120 Hz and 0.15 ms. Furthermore, the generated tidal volume and the stimulation pulse frequency were significantly correlated (0.42–0.84, $$p<0.001$$ p < 0.001 ). The results show which stimulation parameter combinations generate the highest tidal volume. We established a guideline on how to set stimulation parameters. The guideline is helpful for future clinical applications of phrenic nerve stimulation.

30 January 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
ALArnhold Lohse
Arnhold Lohse
MDMatthias Manfred Deininger
Matthias Manfred Deininger
JLJohannes Loeser
Johannes Loeser
FRFelix Roehren
Felix Roehren
DZDmitrij Ziles
Dmitrij Ziles
MWMarian Walter
Marian Walter
Mechanical ventilation is essential in intensive care treatment but leads to diaphragmatic atrophy, which in turn contributes to prolonged weaning and increased mortality. One approach to prevent diaphragmatic atrophy while achieving pulmonary ventilation is electrical stimulation of the phrenic nerve. To automize phrenic nerve stimulation resulting in lung protective tidal volumes with lowest possible currents, mathematical models are required. Nerve stimulation models are often complex, so many parameters have to be identified prior to implementation. This paper presents a novel, simplified approach to model phrenic nerve excitation to obtain an individualized patient model using a few data points. The latter is based on the idea that nerve fibers are excited when the electric field exceeds a threshold. The effect of the geometry parameter on the model output was analyzed, and the model was validated with measurement data from a pig trial (RMSE in between 0.44 × 10−2 and 1.64 × 10−2 for parameterized models). The modeled phrenic nerve excitation behaved similarly to the measured tidal volumes, and thus could be used to develop automated phrenic nerve stimulation systems for lung protective ventilation.

5 October 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
PPPhilip von Platen
Philip von Platen
AAAdel Abdelsamed
Adel Abdelsamed
ALArnhold Lohse
Arnhold Lohse
MRMartin Russ
Martin Russ
CWCelina Wolters
Celina Wolters
MWMarian Walter
Marian Walter

31 March 2024 in Lékař a technika - Clinician and Technology
Verified
Journal Article
Open access
PDF file
ALArnhold Lohse
Arnhold Lohse
PPPhilip Von Platen
Philip Von Platen
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
MWMarian Walter
Marian Walter
Acute respiratory distress syndrome (ARDS) is a disease that has a high reported mortality rate. The treatment for ARDS typically involves mechanical ventilation that is tailored to each patient's needs. A crucial aspect of this treatment is maintaining adequate oxygen saturation of haemoglobin by setting the fraction of inspired oxygen. This paper proposes a design method of robust proportional-integral-derivative (PID) controllers using a gas exchange model during ARDS. Several PID controllers were synthesized for different sub-operational ranges defined by measurable quantities of the mechanical ventilator and the patient using a mixed sensitivity H∞ approach. In simulations, the controller demonstrated high robustness to external changes and changes in the patient's condition, with saturation always above 88%. Although further validation of the controller is required, the results indicate that the presented robust control method has the potential to be clinically relevant.

12 February 2025 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
ALArnhold Lohse
Arnhold Lohse
FRFelix Röhren
Felix Röhren
PPPhilip von Platen
Philip von Platen
CBCarl-Friedrich Benner
Carl-Friedrich Benner
DZDmitrij Ziles
Dmitrij Ziles
MWMarian Walter
Marian Walter