29 March 2020 in Critical Care
The level of automation in mechanical ventilation has been steadily increasing over the last few decades. There has recently been renewed interest in physiological closed-loop control of ventilation. The development of these systems has followed a similar path to that of manual clinical ventilation, starting with ensuring optimal gas exchange and shifting to the prevention of ventilator-induced lung injury. Systems currently aim to encompass both aspects, and early commercial systems are appearing. These developments remain unknown to many clinicians and, hence, limit their adoption into the clinical environment. This review shows the evolution of the physiological closed-loop control of mechanical ventilation.
16 May 2023 in BioMedical Engineering OnLine
Background: Mechanical ventilation is an essential component in the treatment of patients with acute respiratory distress syndrome. Prompt adaptation of the settings of a ventilator to the variable needs of patients is essential to ensure personalised and protective ventilation. Still, it is challenging and time-consuming for the therapist at the bedside. In addition, general implementation barriers hinder the timely incorporation of new evidence from clinical studies into routine clinical practice. Results: We present a system combing clinical evidence and expert knowledge within a physiological closed-loop control structure for mechanical ventilation. The system includes multiple controllers to support adequate gas exchange while adhering to multiple evidence-based components of lung protective ventilation. We performed a pilot study on three animals with an induced ARDS. The system achieved a time-in-target of over 75 % for all targets and avoided any critical phases of low oxygen saturation, despite provoked disturbances such as disconnections from the ventilator and positional changes of the subject. Conclusions: The presented system can provide personalised and lung-protective ventilation and reduce clinician workload in clinical practice.
1 September 2018 in at - Automatisierungstechnik
Left ventricular assist devices (LVADs) have become a viable alternative to heart transplantation in heart failure therapy. In clinical practice, rotary blood pumps used as LVADs are operated at a constant rotational speed and thus do not adapt to the varying demand of the patient. This paper presents a robust control approach for automatic adaptation of the blood pump speed to the blood flow demand of the patient’s body, which enables a defined load sharing between an LVAD and the native ventricle. Robust stability was checked using a detailed model of the human cardiovascular system with uncertainties that describe the most important native physiological control loops as well as a range of pathologies. The robust assistance controller was tested in an in vivo setup and was able to stabilize the cardiovascular system after myocardial infarction.
11 December 2024 in IEEE Transactions on Human-Machine Systems
Acknowledging the vital importance of fatigue management for improving rehabilitation results, customizing treatment, safeguarding patient well-being, and enhancing the quality of life of hemiplegic patients, this study presents the development of a tailored fatigue model and a corresponding human-in-the-loop (HiL) control system for exoskeleton-assisted walking. For this, the selected three-compartment controller fatigue model including a resting recovery parameter was adapted to a dynamic walking task scenario, incorporating a torque–velocity–angle dependency to quantify muscle activity. The model parameters were experimentally verified in a study with six healthy subjects, demonstrating accurate prediction of maximum voluntary contraction (MVC) decline with an average mean absolute error of 4.9%MVC. Subsequently, an HiL control mechanism was developed, utilizing ratings of perceived fatigue and state of fatigue values as reference metrics. The presented control approach effectively regulates fatigue levels within a 0%MVC–6%MVC steady-state error range during simulations. Experimental validation confirmed this performance, however, with partly higher steady-state errors mainly due to the restrictions of the exoskeleton's assistance. This preliminary study provides a promising foundation for future research, demonstrating the potential to manage fatigue effectively in exoskeleton users, offering an improved, personalized experience.
5 October 2023 in Biomedical Signal Processing and Control