Giulia Verniani

Dr. Giulia Verniani

Prosthodontics, University of Siena, Siena, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
ACAlessio Casucci
Alessio Casucci
GVGiulia Verniani
Giulia Verniani
ABAnne-Lucrèce Barbieri
Anne-Lucrèce Barbieri
NRNicolò Maria Ricci
Nicolò Maria Ricci
ECEdoardo Ferrari Cagidiaco
Edoardo Ferrari Cagidiaco
Marco FerrariMarco Ferrari
Marco Ferrari
PMMA (Polymethylmethacrylate) is the material of choice to fabricate denture bases. Recently, with the introduction of CAD-CAM and 3D printers in dentistry, new materials have been proposed for complete denture manufacturing. Aim: This study compared the flexural strength of different resins fabricated using different technologies (conventional, CAD-CAM-milled, and 3D-printed) and polymerization techniques. Methods: A total of 11 different resins were tested: six PMMA conventional (Acrypol R, Acrypol LL, Acrypol HI, Acrypol Fast, Acryself and Acryslef P), two milled obtained from UDMA PMMA disks (Ivotion disk and Aadva disk, control groups), two 3D-printed PMMA resins (NextDent Denture 3D+, and SprintRayEU Denture Base), and one 3D-printed composite resin (GC Temp Print). Flexural strength was measured using a universal testing machine. One-way ANOVA and Bonferroni post hoc tests were performed; the p-value was set at 0.05 to consider statistically significant differences among the groups. Spearman test was used to evaluate the correlation between polymerization technique and the flexural strength of 3D-printed resins. Results: CAD-CAM-milled specimens showed the highest flexural strength (107.87 MPa for UDMA) followed by 3D-printed composite resins (102.96 MPa). Furthermore, 3D-printed resins polymerized for 40 min with the BB cure unit showed no statistically significant differences with conventional resin groups. Moreover, in all the 3D-printed specimens, a high correlation between polymerization technique and flexural strength was found. Conclusions: In terms of flexural strength, the polymerization technique is a determinant for both acrylic and composite resins. Temp Print can be a potential alternative to fabricating removable dentures and showed promising results when used in combination with pink color resin powder.

5 December 2024 in Journal of Dentistry
Verified
Journal Article
Open access
ACAlessio Casucci
Alessio Casucci
ECEdoardo Ferrari Cagidiaco
Edoardo Ferrari Cagidiaco
GVGiulia Verniani
Giulia Verniani
MFMarco Ferrari
Marco Ferrari
ABAndrea Borracchini
Andrea Borracchini
This study aimed to compare the clinical effectiveness and cost-efficiency of conventional and digital prosthodontic protocols, with a specific focus on milled and 3D-printed digital removable complete dentures. This retrospective clinical study was conducted at the Removable Prosthodontics Department of the University of Siena. 60 patients were divided into two groups: 30 received conventional complete dentures, while the remaining 30 received digital complete dentures (15 milled and 15 3D-printed). Clinical outcomes were assessed using OHIP-14, bite force measurements, and masticatory performance tests before and six months after treatment. Treatment-related metrics, including chairside time, follow-up time, and laboratory costs, were recorded and compared across the groups. Statistical analysis was performed to determine the significance of differences between conventional and digital complete dentures, as well as between milled and 3D-printed digital complete dentures. The study revealed that digital complete dentures significantly reduced chairside time compared to conventional dentures, with average times of 154.31 ± 13.19 min for digital dentures and 218.00 ± 20.75 min for conventional dentures (p < 0.0001). Laboratory costs were found to be statistically lower for digital dentures, (€378.79 ± 137.46 vs. €459.15 ± 63.72, p = 0.0059) compared to conventional dentures. No statistically significant differences were observed in bite force or masticatory performance between the groups. OHIP-14 scores indicated slightly lower patient satisfaction with digital dentures, but the difference was not clinically significant. Digital removable dentures, including both milled and 3D-printed models, offer a practical and efficient alternative to conventional dentures, particularly in terms of reducing chairside time and laboratory costs. Digital removable dentures offer a practical and efficient alternative to conventional dentures, particularly in terms of reducing chairside time and costs. These simplified digital protocols could be applied in residential facilities or within national healthcare programs, improving access to prosthetic care for a larger number of patients.

4 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ACAlessio Casucci
Alessio Casucci
GVGiulia Verniani
Giulia Verniani
WHWissam Sami Haichal
Wissam Sami Haichal
DMDaniele Manfredini
Daniele Manfredini
Marco FerrariMarco Ferrari
Marco Ferrari
ECEdoardo Ferrari Cagidiaco
Edoardo Ferrari Cagidiaco
This study compared the flexural strength of various 3D printed resins fabricated at different building angles (0°, 45°, and 90°). Four groups of resins were tested: Varseo Smile Teeth (Bego GmbH & Co., Bremen, Germany), V-print C&B Temp (Voco GmbH, Cuxhaven, Germany), Bego Triniq (Bego GmbH & Co. KG, Bremen, Germany), and Sprintray Crown (SprintRay, Los Angeles, CA, USA). A digital light processing 3D printer (Asiga MAX UV, NSW, Sydney, Australia) was used to fabricate the samples at the specified build angles (0°, 45°, and 90°) in accordance with the ISO 4049:2019 standard. Flexural strength was measured using a universal testing machine (Instron 5567; Instron Ltd., Norwood, MA, USA), and fracture analysis was performed using a scanning electron microscope (Jeol JSM-6060LV, Tokyo, Japan). Statistical analysis was carried out using the Statistical Package for the Social Sciences (SPSS, version 26; IBM Corp., Chicago, IL, USA). Means and standard deviations were calculated for each group, and statistical differences were assessed using one-way ANOVA followed by the Bonferroni post hoc test (p < 0.05). All tested resins exhibited high flexural strength values. The maximum flexural strength was observed in the 0° printed samples (137.18 ± 18.92 MPa), while the lowest values were recorded for the 90° printed samples (116.75 ± 24.74 MPa). For V-print C&B Temp, the flexural strength at 90° (116.97 ± 34.87 MPa) was significantly lower compared to the 0° (156.56 ± 25.58 MPa) and 45° (130.46 ± 12.33 MPa) orientations. In contrast, Bego Triniq samples printed at 45° (148.91 ± 21.23 MPa) demonstrated significantly higher flexural strength than those printed at 0° (113.37 ± 31.93 MPa) or 90° (100.96 ± 16.66 MPa). Overall, the results indicate that the printing angle has a significant impact on the flexural strength of the materials, with some resins showing lower strength values at the 90° build angle.

4 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
ACAlessio Casucci
Alessio Casucci
GVGiulia Verniani
Giulia Verniani
RHRalph Habib
Ralph Habib
NRNicolò Maria Ricci
Nicolò Maria Ricci
FCFabio Carboncini
Fabio Carboncini
Marco FerrariMarco Ferrari
Marco Ferrari
One of the most critical aspects in intraoral impression is the detection of the finish line, particularly in the case of subgingival preparations. The aim of this in vitro study was to evaluate the accuracy among four different Intra Oral Scanners (IOSs) in scanning a subgingival vertical margins preparation (VP). A reference maxillary typodont (MT) was fabricated with a VP for full crown on #16 and #21. The MT was scanned with a laboratory scanner (Aadva lab scanner, GC, Tokyo, Japan) to obtain a digital MT (dMT) in .stl format file. A group of 40 digital casts (dIOC) were obtained by scanning the MT 10 times with four different IOSs: Trios 3, 3Shape A/S; I700, Medit; Vivascan, Ivoclar; and Experimental IOS, GC. All the obtained dIOCs were imported into an inspection software program (Geomagic Control X; 3D SYSTEMS) to be superimposed to the dMT in order to calculate trueness. Therefore, in order to calculate precision, all the scans of the same scanner group were superimposed onto the cast that obtained the best result of trueness. The results were collected as the root mean square value (RMS) on the #16 and #21 abutment surfaces and on a marginal area positioned 1 mm above and below the gingival margin. A nonparametric analysis Kruskal–Wallis test was performed to compare the RMS values obtained in the different iOS groups for trueness and precision. Statistical significance was set at 0.05. For the trueness on the #16 abutment, the Vivascan reported statistically lower values, while on the #21 abutment, Vivascan (56.0 ± 12.1) and Experimental IOS, GC (59.2 ± 2.7) performed statistically better than the others. Regarding precision, Experimental IOS, GC were significantly better than the others on #16 (10.7 ± 2.1) and in the #21 area Experimental, GC, and Trios 3 performed statistically better(16.9 ± 13.8; 18.0 ± 2.7). At the subgingival marginal level for both #16 and #21, all the IOS reported reduced accuracy compared to clinical acceptance.

7 August 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
GVGiulia Verniani
Giulia Verniani
ACAlessio Casucci
Alessio Casucci
Matteo ValMatteo Val
Matteo Val
Gennaro RuggieroGennaro Ruggiero
Gennaro Ruggiero
DMDaniele Manfredini
Daniele Manfredini
ECEdoardo Ferrari Cagidiaco
Edoardo Ferrari Cagidiaco
This study compares the clinical performances of two lithium disilicate (Initial LiSi press vs. Initial LiSi Block, GC Corp.) and a 3D printed resin (Temp Print, GC Corp.) partial crown using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after one year of clinical service. Eighty-nine partial adhesive restorations on posterior teeth were realized using different materials: Group 1 used Initial LiSi press, Group 2 used Initial LiSi Block, and Group 3 used Temp Print. An analog workflow was used to realize the restoration of Group 1, while a fully digital workflow was used for Groups 2 and 3. The modified USPHS parameters, together with periodontal parameters, were collected at baseline and at the one-year recall. Contingency tables to assess for significant differences of success over time in each group were used. All modified USPHS parameters showed Alpha or Bravo; no Charlie was recorded. No statistically significant difference emerged between the three groups in any of the assessed variables (p > 0.05). All modified USPHS scores were compatible with the outcome of clinical success, no restoration was replaced or repaired, and the survival rate was 100% at the one-year recall. No difference was found between the traditional and digital workflows used to fabricate the restorations.

3 April 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
GVGiulia Verniani
Giulia Verniani
Marco FerrariMarco Ferrari
Marco Ferrari
DMDaniele Manfredini
Daniele Manfredini
ECEdoardo Ferrari Cagidiaco
Edoardo Ferrari Cagidiaco
Pressed lithium disilicate is largely used for veneer manufacturing, but a new block formulation has recently been released on the market. This study evaluated the clinical performance of milled lithium disilicate veneers (LiSi Block, GC Co., Tokyo, Japan) realized with a fully digital or hybrid workflow using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 24 months of clinical service together with the patient’s satisfaction using the Visual Analog Scale (VAS). A total of 105 veneers on natural anterior teeth were made on twenty-nine patients with LiSi Block (GC, Tokyo, Japan). Patients were randomly divided into three groups: Group 1, 35 veneers realized with a completely digital workflow using Trios 3 (3Shape A/S, Copenhagen, Denmark); Group 2, 35 veneers realized with a completely digital workflow using Experimental IOS (GC, Tokyo, Japan); and Group 3, 35 veneers realized with a hybrid workflow. The restorations were followed up for 24 months, and the modified USPHS evaluation was performed at baseline, 12 months, and 24 months together with periodontal evaluation. Repeated measures two-way ANOVA and the Tukey test were applied to compare the modified USPHS method values (α = 0.05). STATISTICA 10.0 software and SIGMAPLOT 12.0 software were used to perform statistical analysis. There were no statistically significant differences between the three groups and with the interaction of group vs. time periods. The satisfaction scores of 7.35 ± 1.8 and 9.4 ± 0.37 were recorded before and after treatment, respectively. Milled lithium disilicate veneers showed a good clinical outcome after 2 years of clinical service. No difference was found between fully digital or hybrid workflow.