An ideal dental adhesive should provide retentive strength, marginal seal, be relatively simple to achieve and demonstrate clinical durability. Future improvements in adhesive bonding to tooth structure require in vitro test methods that provide reliable data for materials development and/or evaluation of experimental variables. The objective of this project was to identify a test method that is relatively easy to perform, repeatable and ultimately useful for predicting clinical outcomes. The Academy of Dental Materials initiated a project to develop and distribute guidance documents on laboratory test methods that are useful for the evaluation of dental adhesives and cements, composite resins and ceramics. The dental adhesive sub-group has identified the micro-tensile bond strength test, especially after subjecting the specimens to a durability challenge, as currently the best practical surrogate measure of dental composite restoration retention. The following μTBS guidance is meant to aid the researcher in conducting the μTBS test. The authors, while recognizing the limitations of a static, strength-based test method, welcome comments and suggestions for improvements of this guidance document in future revisions.
The continuous development in dental processing ensures new opportunities in the field of fixed prosthodontics in a complete virtual environment without any physical model situations. The aim was to compare fully digitalized workflows to conventional and/or mixed analog-digital workflows for the treatment with tooth-borne or implant-supported fixed reconstructions. A PICO strategy was executed using an electronic (MEDLINE, EMBASE, Google Scholar) plus manual search up to 2016–09-16 focusing on RCTs investigating complete digital workflows in fixed prosthodontics with regard to economics or esthetics or patient-centered outcomes with or without follow-up or survival/success rate analysis as well as complication assessment of at least 1 year under function. The search strategy was assembled from MeSH-Terms and unspecific free-text words: {((“Dental Prosthesis” [MeSH]) OR (“Crowns” [MeSH]) OR (“Dental Prosthesis, Implant-Supported” [MeSH])) OR ((crown) OR (fixed dental prosthesis) OR (fixed reconstruction) OR (dental bridge) OR (implant crown) OR (implant prosthesis) OR (implant restoration) OR (implant reconstruction))} AND {(“Computer-Aided Design” [MeSH]) OR ((digital workflow) OR (digital technology) OR (computerized dentistry) OR (intraoral scan) OR (digital impression) OR (scanbody) OR (virtual design) OR (digital design) OR (cad/cam) OR (rapid prototyping) OR (monolithic) OR (full-contour))} AND {(“Dental Technology” [MeSH) OR ((conventional workflow) OR (lost-wax-technique) OR (porcelain-fused-to-metal) OR (PFM) OR (implant impression) OR (hand-layering) OR (veneering) OR (framework))} AND {((“Study, Feasibility” [MeSH]) OR (“Survival” [MeSH]) OR (“Success” [MeSH]) OR (“Economics” [MeSH]) OR (“Costs, Cost Analysis” [MeSH]) OR (“Esthetics, Dental” [MeSH]) OR (“Patient Satisfaction” [MeSH])) OR ((feasibility) OR (efficiency) OR (patient-centered outcome))}. Assessment of risk of bias in selected studies was done at a ‘trial level’ including random sequence generation, allocation concealment, blinding, completeness of outcome data, selective reporting, and other bias using the Cochrane Collaboration tool. A judgment of risk of bias was assigned if one or more key domains had a high or unclear risk of bias. An official registration of the systematic review was not performed. The systematic search identified 67 titles, 32 abstracts thereof were screened, and subsequently, three full-texts included for data extraction. Analysed RCTs were heterogeneous without follow-up. One study demonstrated that fully digitally produced dental crowns revealed the feasibility of the process itself; however, the marginal precision was lower for lithium disilicate (LS2) restorations (113.8 μm) compared to conventional metal-ceramic (92.4 μm) and zirconium dioxide (ZrO2) crowns (68.5 μm) (p < 0.05). Another study showed that leucite-reinforced glass ceramic crowns were esthetically favoured by the patients (8/2 crowns) and clinicians (7/3 crowns) (p < 0.05). The third study investigated implant crowns. The complete digital workflow was more than twofold faster (75.3 min) in comparison to the mixed analog-digital workflow (156.6 min) (p < 0.05). No RCTs could be found investigating multi-unit fixed dental prostheses (FDP). The number of RCTs testing complete digital workflows in fixed prosthodontics is low. Scientifically proven recommendations for clinical routine cannot be given at this time. Research with high-quality trials seems to be slower than the industrial progress of available digital applications. Future research with well-designed RCTs including follow-up observation is compellingly necessary in the field of complete digital processing.
Critical measurements for understanding accretion and the dust/gas ratio in the solar nebula, where planets were forming 4.5 billion years ago, are being obtained by the GIADA (Grain Impact Analyser and Dust Accumulator) experiment on the European Space Agency’s Rosetta spacecraft orbiting comet 67P/Churyumov-Gerasimenko. Between 3.6 and 3.4 astronomical units inbound, GIADA and OSIRIS (Optical, Spectroscopic, and Infrared Remote Imaging System) detected 35 outflowing grains of mass 10 −10 to 10 −7 kilograms, and 48 grains of mass 10 −5 to 10 −2 kilograms, respectively. Combined with gas data from the MIRO (Microwave Instrument for the Rosetta Orbiter) and ROSINA (Rosetta Orbiter Spectrometer for Ion and Neutral Analysis) instruments, we find a dust/gas mass ratio of 4 ± 2 averaged over the sunlit nucleus surface. A cloud of larger grains also encircles the nucleus in bound orbits from the previous perihelion. The largest orbiting clumps are meter-sized, confirming the dust/gas ratio of 3 inferred at perihelion from models of dust comae and trails.
This literature review summarizes the most recent and reliable evidence on post systems. A search was limited to review articles published over the last 10 years in dental journals with an impact factor. Papers cited in the initially retrieved review articles were also included if significant. Preservation of tooth tissue, presence of a ferrule effect, and adhesion are regarded as the most effective conditions for long‐term success of post‐endodontic restorations. Adhesively luted fibre‐reinforced composite post restorations have demonstrated satisfactory survival rates over relatively long follow‐up periods. The clinical effectiveness of such restorations has been mainly ascribed to the more biomimetic behaviour of fibre‐reinforced composite posts that reduces the risk of vertical root fractures. The most common type of failure when using fibre posts is post debonding and it is generally agreed that achieving stable adhesion to intraradicular dentine is more challenging than to coronal dentine. Several factors related to endodontic treatment, root canal shape, post space preparation, post translucency, adhesive cement handling and curing may have an influence on the outcome of the luting procedure. The most reliable results in fibre post cementation are obtained by etch‐and‐rinse adhesives in combination with dual‐cure resin cements. The use of self‐adhesive resin cements has also been proposed. Simplification is an obvious advantage of these new materials. However, the durability of their bond still needs to be verified with long‐term clinical studies. Several techniques for pre‐treating the fibre‐reinforced composite post surface have been tested with the aim of improving the bond strength at the post‐core and post‐cement interfaces. Silicoating followed by silanization currently appears to be the most effective and convenient method for this purpose. In conclusion, the available evidence validates the use of fibre posts as an alternative to metal posts and preferably to other tooth‐coloured posts, such as zirconia dowels, in the restoration of endodontically treated teeth. Longer term clinical trials are expected to further strengthen this evidence.