Lianne Koinis

Ms. Lianne Koinis

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LKLianne Koinis
Lianne Koinis
VFVinuja Fernando
Vinuja Fernando
RFR. Dineth Fonseka
R. Dineth Fonseka
PNPragadesh Natarajan
Pragadesh Natarajan
MMMonish Maharaj
Monish Maharaj
RMRalph Mobbs
Ralph Mobbs
Introduction: Gait analysis is a vital tool in the assessment of human movement and has been widely used in clinical settings to identify potential abnormalities in individuals. However, there is a lack of consensus on the normative values for gait metrics in large populations. The primary objective of this study is to establish a normative database of spatiotemporal gait metrics across various age groups, contributing to a broader understanding of human gait dynamics. By doing so, we aim to enhance the clinical utility of gait analysis in diagnosing and managing health conditions. Methods: We conducted an observational case–control study involving 313 healthy participants. The MetaMotionC IMU by Mbientlab Inc., equipped with a triaxial accelerometer, gyroscope, and magnetometer, was used to capture gait data. The IMU was placed at the sternal angle of each participant to ensure optimal data capture during a 50 m walk along a flat, unobstructed pathway. Data were collected through a Bluetooth connection to a smartphone running a custom-developed application and subsequently analysed using IMUGaitPY, a specialised version of the GaitPY Python package. Results: The data showed that gait speeds decrease with ageing for males and females. The fastest gait speed is observed in the 41–50 age group at 1.35 ± 0.23 m/s. Males consistently exhibit faster gait speeds than females across all age groups. Step length and cadence do not have clear trends with ageing. Gait speed and step length increase consistently with height, with the tallest group (191–200 cm) walking at an average speed of 1.49 ± 0.12 m/s, with an average step length of 0.91 ± 0.05 m. Cadence, however, decreases with increasing height, with the tallest group taking 103.52 ± 5.04 steps/min on average. Conclusions: This study has established a comprehensive normative database for the spatiotemporal gait metrics of gait speed, step length, and cadence, highlighting the complexities of gait dynamics across age and sex groups and the influence of height. Our findings offer valuable reference points for clinicians to distinguish between healthy and pathological gait patterns, facilitating early detection and intervention for gait-related disorders. Moreover, this database enhances the clinical utility of gait analysis, supporting more objective diagnoses and assessments of therapeutic interventions. The normative database provides a valuable reference future research and clinical practice. It enables a more nuanced understanding of how gait evolves with age, gender, and physical stature, thus informing the development of targeted interventions to maintain mobility and prevent falls in older adults. Despite potential selection bias and the cross-sectional nature of the study, the insights gained provide a solid foundation for further longitudinal studies and diverse sampling to validate and expand upon these findings.

31 October 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
PNPragadesh Natarajan
Pragadesh Natarajan
RFR. Dineth Fonseka
R. Dineth Fonseka
MMMonish Movin Maharaj
Monish Movin Maharaj
LKLianne Koinis
Lianne Koinis
RMRalph Jasper Mobbs
Ralph Jasper Mobbs
Background: Surgical procedures involving the hip, knee, or spine represent a majority of orthopaedic procedures performed electively in the health care system. Postoperative care is a key aspect of surgery and mobilisation without injury is the primary objective. Recent advances in wearable technologies allow objective evaluation of walking metrics to inform and guide postoperative care following orthopaedic surgery. Purpose: The aim of this scoping review is to explore current applications of wearable devices, objective data capture and gait analysis in monitoring postoperative recovery following commonly performed elective orthopaedic procedures of the hip, knee and spine. Methods: A search against pre-defined criteria was performed on the following scientific databases from date of inception to February 28th, 2021: Medline (via OvidSP), Embase (via OvidSP) and Cochrane Library (via CENTRAL). Data were collected according to a predetermined checklist including study participants, surgery, wearable device (model), sensor location, and monitoring parameters such as mobility metrics, monitoring timepoints and monitoring duration for each study included in our review. Quality was assessed independently using the Newcastle Ottawa Scale (NOS). Conclusions: To our knowledge, this is the first review of wearable monitoring (of postoperative recovery) following hip, knee and spine surgery. Patients undergoing elective orthopaedic procedures may benefit from wearable monitoring of their walking health and mobility metrics.

14 February 2024 in Surgical Techniques Development
Verified
Journal Article
Open access
PDF file
RFR. Dineth Fonseka
R. Dineth Fonseka
PNPragadesh Natarajan
Pragadesh Natarajan
MMMonish Maharaj
Monish Maharaj
LKLianne Koinis
Lianne Koinis
LSLuke Wicent Sy
Luke Wicent Sy
RMRalph Mobbs
Ralph Mobbs
Background: Outcome measurement in lumbar surgery is traditionally performed using patient questionnaires that may be limited by subjectivity. Objective gait analysis may supplement patient assessment but must be clinically viable. We assessed gait metrics in lumbar spine patients pre- and postoperatively using a small and lightweight wearable sensor. Methods: This was a prospective observational study with intervention including 12 patients undergoing lumbar spine surgery and 24 healthy controls matched based on age and sex. All the subjects underwent gait analysis using the single-point wearable MetaMotionC sensor. The lumbar spine patients also completed traditional patient questionnaires including the Oswestry Disability Index (ODI). Results: The ODI score significantly improved in the patients from the baseline to six weeks postoperatively (42.4 to 22.8; p = 0.01). Simultaneously, the patients demonstrated significant improvements in gait asymmetry (asymmetry in step length, swing time, single support time, and double support time, by 17.4–60.3%; p ≤ 0.039) and variability (variability in gait velocity, step time, step length, stance time, swing time, single support time, and double support time, by 21.0–65.8%; p ≤ 0.023). After surgery, changes in most spatiotemporal (gait velocity, step length, stance time, swing time, and single limb support time) and asymmetry (asymmetry in step time, stance time, swing time, and single limb support time) metrics correlated strongly (magnitude of r = 0.581–0.914) and significantly (p ≤ 0.037) with changes in the ODI. Conclusions: Gait analysis using a single-point wearable sensor can demonstrate objective evidence of recovery in lumbar spine patients after surgery. This may be used as a routine pre- and postoperative assessment during scheduled visits to the clinic.

9 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LKLianne Koinis
Lianne Koinis
MMMonish Maharaj
Monish Maharaj
PNPragadesh Natarajan
Pragadesh Natarajan
RFR. Dineth Fonseka
R. Dineth Fonseka
VFVinuja Fernando
Vinuja Fernando
RMRalph Mobbs
Ralph Mobbs
Background: Gait analysis is a vital tool for evaluating overall health and predicting outcomes such as mortality and cognitive decline. This study explores how normal and obese BMI categories impact gait dynamics, addressing gaps in understanding the effect of body composition on specific gait parameters. Research Question: The primary objective is to investigate differences in spatiotemporal gait parameters—specifically, gait speed, step length, cadence, and double support time—between normal and obese BMI groups to understand the effects of obesity on gait. Methods: This observational case-control study analyzed spatiotemporal gait metrics from 163 participants, using inertial measurement units (IMUs) to collect data on various gait parameters. Statistical analyses explored the relationship between BMI categories and these metrics. Results: No significant differences were found in gait speed, cadence, stride duration, or double support time between the normal and obese groups. However, significant differences were identified in age, hypertension prevalence, balance problems, and the incidence of falls, emphasizing the complex effects of obesity on factors influencing gait stability. Significance: This study contributes to our understanding of obesity’s impact on gait by highlighting the need to consider associated health and stability parameters. These findings prompt a re-evaluation of how BMI is integrated into clinical gait assessments and emphasize the necessity for personalized healthcare strategies. This research highlights the importance of future studies with larger, more diverse populations and a wider array of biomechanical measures to dissect the relationship between BMI, body composition, and gait dynamics.

18 January 2024 in Journal of Patient-Reported Outcomes
Verified
Journal Article
Open access
PDF file
RMRalph J. Mobbs
Ralph J. Mobbs
RFR. Dineth Fonseka
R. Dineth Fonseka
PNPragadesh Natarajan
Pragadesh Natarajan
LKLianne Koinis
Lianne Koinis
MMMonish Maharaj
Monish Maharaj
Background: Established health-related quality of life scores do not consider both subjective and objective indices of health. We propose the subjective and objective quality of life score (SOQOL) for the comprehensive assessment of health-related quality of life and aim to provide normative population data. The SOQOL is compatible with smartphone applications, allowing widespread use on a global scale. Methods: Normative SOQOL population data was sourced from pre-existing datasets on the EQ-5D-5L, daily step count, and walking speed. Normative values were calculated using weighted grand means. We trialled the SOQOL in a group of five patients presenting to a spinal neurosurgery clinic. Results: SOQOL scores decreased with age, and women had lower scores in every age group. In our case series, the spine patients with the biggest SOQOL deficit compared to age- and sex-matched population averages were found to be surgical while the rest were non-surgical. Conclusions: The SOQOL shows promise as a simple and effective scoring tool that is compatible with smartphones, potentially useful for screening in primary and specialized care settings, and for assessment following healthcare interventions. This study, however, is preliminary, and the findings are primarily suggestive. They underline the necessity for future, more comprehensive studies to validate and expand upon these initial observations. The conclusion of both this abstract and the full paper will clearly state these limitations and the preliminary nature of the study.

8 November 2023 in Surgical Techniques Development
Verified
Journal Article
Open access
PDF file
TATajrian Amin
Tajrian Amin
WPWilliam C. H. Parr
William C. H. Parr
PNPragadesh Natarajan
Pragadesh Natarajan
ALAndrew Lennox
Andrew Lennox
LKLianne Koinis
Lianne Koinis
RMRalph Mobbs
Ralph Mobbs
Introduction: Hemivertebrae are a common defect of vertebral formation, potentially resulting in debilitating congenital scoliosis and necessitating highly traumatic surgery. Virtual surgical planning (VSP) and 3D-printed patient-specific implants (PSIs) have increasingly been applied to complex spinal surgery, and offer a range of potential benefits. Research Question: We report the use of 3D-printed PSIs and VSP as part of a two-level anterior lumbar interbody fusion (ALIF) for the management of lateral hemivertebra and congenital scoliosis. Material and Methods: A 53-year-old male with chronic low-back pain, due to L4 hemivertebra and mild congenital scoliosis, presented with new-onset leg pain. CT revealed L4/5 and L5/S1 degeneration and foraminal stenosis. Given the complex anatomy and extensive multi-level osteophytosis, 3D-printed PSIs were designed, manufactured, and implanted as part of a two-level ALIF. Results: Excellent implant fit was achieved intraoperatively, confirmed via postoperative imaging. VSP assisted with navigating challenging bony and vascular anatomy. Three-month postoperative imaging demonstrated construct stability, early signs of bony fusion, with implant placement, spinal curvature, and disc height corrections closely matching the VSP. Clinically, the patient’s pain and functional impairment had effectively resolved by nine-month follow up, as demonstrated through subjective and objective measures. Discussion and Conclusions: Virtual surgical planning and 3D-printed PSIs can be useful surgical aids in the management of the often-complex cases involving hemivertebrae and congenital scoliosis. This case of congenital pathology adds to the growing reports of PSI application to a variety of complex spinal pathologies, with analyses showing a close match of the postoperative construct to the preoperative VSP.