Monish Maharaj

Dr. Monish Maharaj


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
LSLauren Simpson
Lauren Simpson
MMMonish Maharaj
Monish Maharaj
RMRalph Mobbs
Ralph Mobbs
Wearables consist of numerous technologies that are worn on the body and measure parameters such as step count, distance travelled, heart rate and sleep quantity. Recently, various wearable systems have been designed capable of detecting spinal posture and providing live biofeedback when poor posture is sustained. It is hypothesised that long-term use of these wearables may improve spinal posture. To (1) examine the capabilities of current devices assessing spine posture, (2) to identify studies implementing such devices in the clinical setting and (3) comment on the clinical practicality of integration of such devices into routine care where appropriate. A comprehensive systematic review was conducted in adherence to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Guidelines (PRISMA) across the following databases: PubMed; MEDLINE; EMBASE; Cochrane; and Scopus. Articles related to wearables systems able to measure spinal posture were selected amongst all published studies dated from 1980 onwards. Extracted data was collected as per a predetermined checklist including device types, study objectives, findings and limitations. A total of 37 articles were extensively reviewed and analysed in the final review. The proposed wearables most commonly used Inertial Measurement Units (IMUs) as the underlying technology. Wearables measuring spinal posture have been proposed to be used in the following settings: post-operative rehabilitation; treatment of musculoskeletal disorders; diagnosis of pathological spinal posture; monitoring of progression of Parkinson’s Disease; detection of falls; workplace occupational health and safety; comparison of interventions. This is the first and only study to specifically review wearable devices that monitor spinal posture. Our findings suggest that currently available devices are capable of assessing spinal posture with good accuracy in the clinical setting. However, further validation regarding the long-term use of these technologies and improvements regarding practicality is required for commercialisation.

15 June 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
ACAnanya Chakravorty
Ananya Chakravorty
RMRalph Mobbs
Ralph Mobbs
DADavid B Anderson
David B Anderson
KRKaitlin Rooke
Kaitlin Rooke
KPKevin Phan
Kevin Phan
WCWen Jie Choy
Wen Jie Choy
The purpose of this systematic review was to evaluate the accuracy and reliability of wearable devices for objective gait measurement of Lumbar Spinal Stenosis (LSS) patients, with a focus on relevant gait metrics. Systematic searches were conducted of five electronic databases to identify studies that assessed gait metrics by wearable or portable technology. Data was collected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Four articles were identified for inclusion in this review. The objectives, methodology and quality of the studies varied. No single gait metric was investigated in all four studies, making comparison difficult. The most relevant metrics reported included gait cycle, gait velocity, step length and cadence, which were reported in two studies. Two studies explored gait symmetry. Differences between LSS patients and normal healthy subjects are demonstrable using wearable technology. The measurements of gait cycle, cadence, step length, gait velocity, and number of steps with wearable devices can be used in the gait measurement of LSS patients for initial assessment, and objective outcomes following interventions. However, data and analysis are limited, and further studies are necessary to comment on reliability.

1 April 2016 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
MMMonish Maharaj
Monish Maharaj
JHJarred A. Hogan
Jarred A. Hogan
KPKevin Phan
Kevin Phan
RMRalph J. Mobbs
Ralph J. Mobbs

20 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LKLianne Koinis
Lianne Koinis
VFVinuja Fernando
Vinuja Fernando
RFR. Dineth Fonseka
R. Dineth Fonseka
PNPragadesh Natarajan
Pragadesh Natarajan
MMMonish Maharaj
Monish Maharaj
RMRalph Mobbs
Ralph Mobbs
Introduction: Gait analysis is a vital tool in the assessment of human movement and has been widely used in clinical settings to identify potential abnormalities in individuals. However, there is a lack of consensus on the normative values for gait metrics in large populations. The primary objective of this study is to establish a normative database of spatiotemporal gait metrics across various age groups, contributing to a broader understanding of human gait dynamics. By doing so, we aim to enhance the clinical utility of gait analysis in diagnosing and managing health conditions. Methods: We conducted an observational case–control study involving 313 healthy participants. The MetaMotionC IMU by Mbientlab Inc., equipped with a triaxial accelerometer, gyroscope, and magnetometer, was used to capture gait data. The IMU was placed at the sternal angle of each participant to ensure optimal data capture during a 50 m walk along a flat, unobstructed pathway. Data were collected through a Bluetooth connection to a smartphone running a custom-developed application and subsequently analysed using IMUGaitPY, a specialised version of the GaitPY Python package. Results: The data showed that gait speeds decrease with ageing for males and females. The fastest gait speed is observed in the 41–50 age group at 1.35 ± 0.23 m/s. Males consistently exhibit faster gait speeds than females across all age groups. Step length and cadence do not have clear trends with ageing. Gait speed and step length increase consistently with height, with the tallest group (191–200 cm) walking at an average speed of 1.49 ± 0.12 m/s, with an average step length of 0.91 ± 0.05 m. Cadence, however, decreases with increasing height, with the tallest group taking 103.52 ± 5.04 steps/min on average. Conclusions: This study has established a comprehensive normative database for the spatiotemporal gait metrics of gait speed, step length, and cadence, highlighting the complexities of gait dynamics across age and sex groups and the influence of height. Our findings offer valuable reference points for clinicians to distinguish between healthy and pathological gait patterns, facilitating early detection and intervention for gait-related disorders. Moreover, this database enhances the clinical utility of gait analysis, supporting more objective diagnoses and assessments of therapeutic interventions. The normative database provides a valuable reference future research and clinical practice. It enables a more nuanced understanding of how gait evolves with age, gender, and physical stature, thus informing the development of targeted interventions to maintain mobility and prevent falls in older adults. Despite potential selection bias and the cross-sectional nature of the study, the insights gained provide a solid foundation for further longitudinal studies and diverse sampling to validate and expand upon these findings.

1 December 2017 in Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
KPKevin Phan
Kevin Phan
ALAlan Lackey
Alan Lackey
NCNicholas Chang
Nicholas Chang
YHYam Ting Ho
Yam Ting Ho
DADavid Abi-Hanna
David Abi-Hanna
RMRalph Mobbs
Ralph Mobbs
Background: Recurrent intervertebral disc herniation is a relatively common occurrence after primary discectomy for lumbar intervertebral disc herniation. For recurrent herniations after repeat discectomies, a growing body of evidence suggests that fusion is effective in appropriately selected cases. Theoretically, anterior lumbar interbody fusion (ALIF) allows for comprehensive discectomy, less trauma to spinal nerves and paraspinal muscles and avoidance of the disadvantages of repeat posterior approaches. However, ALIF has also been associated with risk of vascular injury and retrograde ejaculation. This current systematic review and meta-analysis aims to assess the viability of ALIF as a surgical treatment for recurrent disc herniations. Methods: Seven studies were identified from six electronic databases and secondary reference lists. Pre-defined endpoints were extracted from the included studies and meta-analyzed. Results: For the 181 patients from included studies, ALIF resulted in significant average improvements in Oswestry Disability Index (ODI) scores (50.49%, P<0.001), Visual Analogue Scale (VAS) back pain scores (47.85%, P<0.001) and VAS leg pain scores (37.00%, P<0.001). Average blood loss was acceptable at 122 mL (P<0.001) and average operation duration was 89 minutes (P<0.001). Average hospital stay was 5.28 days (P<0.001). Only 22 perioperative complications were reported, with subsidence the most commonly reported complication. Conclusions: Pooled evidence suggests that ALIF is a feasible approach for the treatment of recurrent disc herniations, demonstrating significant improvements in back and leg pain and minimal complications. These findings warrant further investigation in large prospective registries and multi-center studies.

1 October 2020 in The Spine Journal
Verified
Journal Article
Closed access
PRPrashanth J. Rao
Prashanth J. Rao
MMMonish Maharaj
Monish Maharaj
CCChristine Chau
Christine Chau
PTPeter Taylor
Peter Taylor
KPKevin Phan
Kevin Phan
RMRalph Mobbs
Ralph Mobbs