Rocio B. Dominguez

Dr. Rocio B. Dominguez

CONACyT-CIMAV
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
EMEider Pedro Aparicio Martínez
Eider Pedro Aparicio Martínez
AIAdriana Ibarra
Adriana Ibarra
Iván Alziri Estrada-MorenoIván Alziri Estrada-Moreno
Iván Alziri Estrada-Moreno
VOVelia Osuna
Velia Osuna
RDRocio B. Dominguez
Rocio B. Dominguez

1 February 2012 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
RMRupesh K. Mishra
Rupesh K. Mishra
RDRocio B. Dominguez
Rocio B. Dominguez
SBSunil Bhand
Sunil Bhand
RMRoberto Muñoz
Roberto Muñoz
Jean Louis MartyJean Louis Marty
Jean Louis Marty

22 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
VOVelia Osuna
Velia Osuna
AVAlejandro Vega
Alejandro Vega
ECErasto Armando Zaragoza Contreras
Erasto Armando Zaragoza Contreras
Iván Alziri Estrada-MorenoIván Alziri Estrada-Moreno
Iván Alziri Estrada-Moreno
RDRocio B. Dominguez
Rocio B. Dominguez
Glucose measurement is a fundamental tool in the daily care of Diabetes Mellitus (DM) patients and healthcare professionals. While there is an established market for glucose sensors, the rising number of DM cases has promoted intensive research to provide accurate systems for glucose monitoring. Polyaniline (PAni) is a conductive polymer with a linear conjugated backbone with sequences of single C–C and double C=C bonds. This unique structure produces attractive features for the design of sensing systems such as conductivity, biocompatibility, environmental stability, tunable electrochemical properties, and antibacterial activity. PAni-based glucose sensors (PBGS) were actively developed in past years, using either enzymatic or non-enzymatic principles. In these devices, PAni played roles as a conductive material for electron transfer, biocompatible matrix for enzymatic immobilization, or sensitive layer for detection. In this review, we covered the development of PBGS from 2015 to the present, and it is not even exhaustive; it provides an overview of advances and achievements for enzymatic and non-enzymatic PBGB PBGS for self-monitoring and continuous blood glucose monitoring. Additionally, the limitations of PBGB PBGS to advance into robust and stable technology and the challenges associated with their implementation are presented and discussed.

3 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LSLuis A. Santana-Jiménez
Luis A. Santana-Jiménez
AMAlfredo Márquez-Lucero
Alfredo Márquez-Lucero
VOVelia Osuna
Velia Osuna
Iván Alziri Estrada-MorenoIván Alziri Estrada-Moreno
Iván Alziri Estrada-Moreno
RDRocio B. Dominguez
Rocio B. Dominguez
The high incidence of Diabetes Mellitus in low-income regions has promoted the development of low-cost alternatives to replace blood-based procedures. In this work, we present a bienzymatic paper-based sensor suitable for the naked-eye detection of glucose in saliva samples. The sensor was obtained by a stamping procedure and modified with chitosan to improve the colorimetric readout. The bienzymatic reaction of GOx-HRP coupled with 2,4,6-tribromo-3-hydroxy benzoic acid was applied for the detection of glucose within a range from 0 to 180 mgdL−1 in buffer and artificial saliva solutions. The visual readout was perceived by the naked eye and registered with an office scanner to evaluate the analytical performance. The results showed a limit of detection of 0.37 mgdL−1 (S/N = 3) with an R.S.D. of 1.69% and a linear range from 1 to 22.5 mgdL−1 with an R2 of 0.99235. The analysis of human saliva samples was performed without pre-processing, achieving recoveries from 92 to 114%. The naked-eye detection was evaluated under two different light settings, showing average recoveries of 108.58 and 90.65% for standard and low illumination. The proposed device showed potential for easy-to-use, sensitive, low-cost, fast, and device-free detection of salivary glucose suitable for untrained personnel operation and limited facilities.

1 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RDRocio B. Dominguez
Rocio B. Dominguez
MOMiguel Alonso Orozco-Alvarado
Miguel Alonso Orozco-Alvarado
GCGiovanny Chávez
Giovanny Chávez
AMAlfredo Márquez-Lucero
Alfredo Márquez-Lucero
Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R2 of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation.

24 September 2014 in Sensors
Verified
Journal Article
Open access
PDF file
RDRocio B. Dominguez
Rocio B. Dominguez
LMLaura Moreno-Barón
Laura Moreno-Barón
RMRoberto Muñoz
Roberto Muñoz
Juan Manuel GutiérrezJuan Manuel Gutiérrez
Juan Manuel Gutiérrez
This paper describes a new method based on a voltammetric electronic tongue (ET) for the recognition of distinctive features in coffee samples. An ET was directly applied to different samples from the main Mexican coffee regions without any pretreatment before the analysis. The resulting electrochemical information was modeled with two different mathematical tools, namely Linear Discriminant Analysis (LDA) and Support Vector Machines (SVM). Growing conditions (i.e., organic or non-organic practices and altitude of crops) were considered for a first classification. LDA results showed an average discrimination rate of 88% ± 6.53% while SVM successfully accomplished an overall accuracy of 96.4% ± 3.50% for the same task. A second classification based on geographical origin of samples was carried out. Results showed an overall accuracy of 87.5% ± 7.79% for LDA and a superior performance of 97.5% ± 3.22% for SVM. Given the complexity of coffee samples, the high accuracy percentages achieved by ET coupled with SVM in both classification problems suggested a potential applicability of ET in the assessment of selected coffee features with a simpler and faster methodology along with a null sample pretreatment. In addition, the proposed method can be applied to authentication assessment while improving cost, time and accuracy of the general procedure.