Background— It has been suggested that inflammatory cells within vulnerable plaques may be visualized by superparamagnetic iron oxide particle-enhanced MRI. The purpose of this study was to determine the time course for macrophage visualization with in vivo contrast-enhanced MRI using an ultrasmall superparamagnetic iron oxide (USPIO) agent in symptomatic human carotid disease. Methods— Eight patients scheduled for carotid endarterectomy underwent multisequence MRI of the carotid bifurcation before and 24, 36, 48, and 72 hours after Sinerem (2.6 mg/kg) infusion. Results— USPIO particles accumulated in macrophages in 7 of 8 patients given Sinerem. Areas of signal intensity reduction, corresponding to USPIO/macrophage-positive histological sections, were visualized in all 7 of these patients, optimally between 24 and 36 hours, decreasing after 48 hours, but still evident up to 96 hours after infusion. Conclusions— USPIO-enhanced MRI of carotid atheroma can be used to identify macrophages in vivo. The temporal change in the resultant signal intensity reduction on MRI suggests an optimal time window for the detection of macrophages on postinfusion imaging.
MRI from Picture to Proton presents the basics of MR practice and theory in a unique way: backwards! The subject is approached just as a new MR practitioner would encounter MRI: starting from the images, equipment and scanning protocols, rather than pages of physics theory. The reader is brought face-to-face with issues pertinent to practice immediately, filling in the theoretical background as their experience of scanning grows. Key ideas are introduced in an intuitive manner which is faithful to the underlying physics but avoids the need for difficult or distracting mathematics. Additional explanations for the more technically inquisitive are given in optional secondary text boxes. The new edition is fully up-dated to reflect the most recent advances, and includes a new chapter on parallel imaging. Informal in style and informed in content, written by recognized effective communicators of MR, this is an essential text for the student of MR.
Background and Purpose— Carotid endarterectomy is currently guided by angiographic appearance on the assumption that the most stenotic lesion visible at angiography is likely to be the lesion from which future embolic events will arise. However, risk of plaque rupture, the most common cause of atherosclerosis-related thromboembolism, is dictated by the composition of the plaque, in particular the degree of inflammation. Angiography may, therefore, be an unreliable method of identifying vulnerable plaques. In this study, plaque inflammation was quantified before endarterectomy using the combination of 18 F fluorodeoxyglucose positron (FDG)-emission tomography (PET) and high-resolution MRI (HRMRI). Methods— Twelve patients, all of whom had suffered a recent transient ischemic attack, had a severe stenosis in the ipsilateral carotid artery, and were awaiting carotid endarterectomy underwent FDG-PET and HRMRI scanning. A semiquantitative estimate of plaque inflammation was calculated for all of the lesions identified on HRMRI. Results— In 7 of 12 patients (58%), high FDG uptake was seen in the lesion targeted for endarterectomy. In the remaining 5 patients, FDG uptake in the targeted lesion was low. In these 5 patients, 3 had nonstenotic lesions identified on HRMRI that exhibited a high level of FDG uptake. All 3 of the highly inflamed nonstenotic lesions were located in a vascular territory compatible with the patients’ presenting symptoms. Conclusions— Our data suggest that angiography may not always identify the culprit lesion. Combined FDG-PET and HRMRI can assess the degree of inflammation in stenotic and nonstenotic plaques and could potentially be used to identify lesions responsible for embolic events.
1 October 2010 in Journal of Cardiovascular Magnetic Resonance
Cardiovascular magnetic resonance (CMR) allows non-invasive phase contrast measurements of flow through planes transecting large vessels. However, some clinically valuable applications are highly sensitive to errors caused by small offsets of measured velocities if these are not adequately corrected, for example by the use of static tissue or static phantom correction of the offset error. We studied the severity of uncorrected velocity offset errors across sites and CMR systems. In a multi-centre, multi-vendor study, breath-hold through-plane retrospectively ECG-gated phase contrast acquisitions, as are used clinically for aortic and pulmonary flow measurement, were applied to static gelatin phantoms in twelve 1.5 T CMR systems, using a velocity encoding range of 150 cm/s. No post-processing corrections of offsets were implemented. The greatest uncorrected velocity offset, taken as an average over a 'great vessel' region (30 mm diameter) located up to 70 mm in-plane distance from the magnet isocenter, ranged from 0.4 cm/s to 4.9 cm/s. It averaged 2.7 cm/s over all the planes and systems. By theoretical calculation, a velocity offset error of 0.6 cm/s (representing just 0.4% of a 150 cm/s velocity encoding range) is barely acceptable, potentially causing about 5% miscalculation of cardiac output and up to 10% error in shunt measurement. In the absence of hardware or software upgrades able to reduce phase offset errors, all the systems tested appeared to require post-acquisition correction to achieve consistently reliable breath-hold measurements of flow. The effectiveness of offset correction software will still need testing with respect to clinical flow acquisitions.