Stacey S. Hickson

Stacey S. Hickson

Auto-generated profile, based on publicly available information

Stacey S. Hickson

University of Cambridge, Addenbrooke's Hospital, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2010 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
SHStacey S. Hickson
Stacey S. Hickson
MBMark Butlin
Mark Butlin
MGMartin John Graves
Martin John Graves
VTValentina Taviani
Valentina Taviani
AAAlberto Avolio
Alberto Avolio
IWIan B. Wilkinson
Ian B. Wilkinson

25 September 2009 in Hypertension Research
Verified
Journal Article
Closed access
SHStacey S Hickson
Stacey S Hickson
MBMark Butlin
Mark Butlin
JBJeremy Broad
Jeremy Broad
AAAlberto Avolio
Alberto Avolio
IWIan B Wilkinson
Ian B Wilkinson
CMCarmel M McEniery
Carmel M McEniery

1 September 2009 in Journal Of Hypertension
Verified
Journal Article
Closed access
SHStacey S Hickson
Stacey S Hickson
MBMark Butlin
Mark Butlin
FMFraz A Mir
Fraz A Mir
JGJohann Graggaber
Johann Graggaber
JCJoseph Cheriyan
Joseph Cheriyan
CMCarmel M McEniery
Carmel M McEniery
Recent evidence suggests that central aortic blood pressure may be a better predictor of cardiovascular risk than peripheral blood pressure. The central SBP (cSBP) can be estimated from the late systolic shoulder of the radial pulse waveform. We compared the second systolic peak of the radial waveform (pSBP2) with the central systolic pressure derived by a generalized transfer function in a large cohort, across a wide age range, of patients from the Anglo-Cardiff Collaborative Trial. We also compared pSBP2 with the true cSBP measured by cardiac catheterization [invasively measured cSBP (cSBPi)]. Noninvasive measurements were made by applanation tonometry using the SphygmoCor device. The aortic pressure waveform was derived from the radial waveform using a validated transfer function. Invasive measures of cSBPi were carried out in a group of 38 patients undergoing diagnostic cardiac angiography, and radial artery pressure waveforms were simultaneously recorded using the SphygmoCor device. Overall, there was a strong correlation (r = 0.99, P < 0.001) and good agreement between pSBP2 and the derived cSBP (mean difference ± SD 1 ± 4 mmHg). However, there was a systematic bias with a greater difference between these measures at lower average pressures. There was also a strong correlation and good agreement between the invasively measured cSBPi and pSBP2 (r = 0.92, P < 0.001, mean difference 2 ± 6 mmHg). The second systolic shoulder of the peripheral pressure waveform approximates the cSBP in a large cohort of patients across a wide age range, but this may be inaccurate at low SBP values.

1 June 2011 in Journal Of Hypertension
Verified
Journal Article
Closed access
SHStacey S Hickson
Stacey S Hickson
KMKaren L Miles
Karen L Miles
BMBarry J McDonnell
Barry J McDonnell
YAYasmin
Yasmin
JCJohn R Cockcroft
John R Cockcroft
CMCarmel M McEniery
Carmel M McEniery
Background The oral contraceptive pill (OCP) is widely prescribed throughout the world. Although it is associated with a small but significant increase in blood pressure, the influence of the OCP on large artery stiffness and wave reflection is unclear. The aim of this study was to determine the relationship between use of the OCP and aortic stiffness and wave reflections in a young, healthy cohort of women. Methods Participants were drawn from the ENIGMA study, which examines the natural history of blood pressure in young adults. A detailed medical history and lifestyle questionnaire, including OCP details were taken. Blood pressure was measured according to the British Hypertension Society guidelines. Aortic pulse wave velocity (aPWV) was measured together with augmentation index (AIx). Stroke volume (SV) and cardiac output (CO) were also assessed. Results Women taking the OCP (n = 225) had a higher SBP and pulse pressure compared with nonusers (n = 660; 112 ± 12 vs. 110 ± 11 and 43 ± 8 vs. 42 ± 8 mmHg, respectively, P < 0.05 for both). CO and SV were also higher (6.6 ± 1.5 vs. 6.3 ± 1.5 l/min, P < 0.01 and 81 ± 16 vs. 78 ± 19 ml, P < 0.05) as was aPWV (5.5 ± 0.7 vs. 5.4 ± 0.7 m/s, P < 0.05). However, there was no difference in DBP (68 ± 9 vs. 69 ± 9 mmHg), mean arterial pressure (81 ± 10 vs. 81 ± 10 mmHg) or AIx (2 ± 12 vs. 3 ± 13%) between the groups. Conclusion Use of the OCP is associated with elevated pulse pressure and SV and a small increase in aPWV in young women. The longer term implications of these effects require further investigation.