Can Yüksel

Dr. Can Yüksel

Diagnostische und Interventionelle Radiologie, RWTH Aachen University, Aachen, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Deutsches Ärzteblatt international
Verified
Journal Article
Closed access
MSMaximilian Schulze-Hagen
Maximilian Schulze-Hagen
CHChristian Hübel
Christian Hübel
MMMichael Meier-Schroers
Michael Meier-Schroers
Can YükselCan Yüksel
Can Yüksel
ASAnton Sander
Anton Sander
CKChristiane Kuhl
Christiane Kuhl
Background: Only limited evidence has been available to date on the accuracy of systematic low-dose chest computed tomography (LDCT) use in the diagnosis of COVID-19 in patients with non-specific clinical symptoms. Methods: The COVID-19 Imaging Registry Study Aachen (COVID-19-Bildgebungs-Register Aachen, COBRA) collects data on imaging in patients with COVID-19. Two of the COBRA partner hospitals (RWTH Aachen University Hospital and Dueren Hospital) systematically perform reverse transcriptase polymerase chain reaction (RT-PCR) from nasopharyngeal swabs as well as LDCT in all patients presenting with manifestations that are compatible with COVID-19. In accordance with the COV-RADS protocol, the LDCT scans were prospectively evaluated before the RT-PCR findings were available in order to categorize the likelihood of COVID-19. Results: From 18 March to 5 May 2020, 191 patients with COVID-19 manifestations (117 male, age 65 +/- 16 years) underwent RT-PCR testing and LDCT. The mean time from the submission of the sample to the availability of the RT-PCR findings was 491 minutes (interquartile range [IQR: 276-1066]), while that from the performance of the CT to the availability of its findings was 9 minutes (IQR: 6-11). A diagnosis of COVID-19 was made in 75/191 patients (39%). The LDCT was positive in 71 of these 75 patients and negative in 106 of the 116 patients without COVID-19, corresponding to 94.7% sensitivity (95% confidence interval [86.9: 98.5]). 91.4% specificity [84.7; 95.8]. positive and negative predictive values of 87.7% [78.5; 93.9] and 96.4% [91.1; 98.6], respectively, and an AUC (area under the curve) of 0.959 [0.930; 0.988]. The initial RT-PCR test results were falsely negative in six patients, yielding a sensitivity of 92.0% [83.4; 97.0]: these six patients had positive LDCT findings. 47.4% of the LDCTs that were negative for COVID-19 (55/116) exhibited pathological pulmonary changes. including infiltrates, that were correctly distinguished from SARS-CoV-2 related changes. Conclusion: In patients with symptoms compatible with COVID-19, LDCT can esablish the diagnosis of COVID-19 with comparable sensitivity to RT-PCR testing. In addition, it offers a high specificity for distinguishing COVID-19 from other diseases associated with the same or similar clinical symptoms. We propose the systematic use of LDCT in addition to RT-PCR testing because it helps correct false-negative RT-PCR results, because its results are available much faster than those of RT-PCR-testing, and because it provides additional diagnostic information useful for treatment planning regardless of the type of the infectious agent.

12 November 2019 in Oxidative Medicine and Cellular Longevity
Verified
Journal Article
Open access
PDF file
JZJenia Kouchek zadeh
Jenia Kouchek zadeh
MZMayagozel B. Zhutdieva
Mayagozel B. Zhutdieva
PLPanagiotis Laspas
Panagiotis Laspas
Can YükselCan Yüksel
Can Yüksel
AMAytan Musayeva
Aytan Musayeva
Adrian GerickeAdrian Gericke
Adrian Gericke
Objective. Atherogenic lipoproteins may impair vascular reactivity consecutively causing tissue damage in multiple organs via abnormal perfusion and excessive reactive oxygen species generation. We tested the hypothesis that chronic hypercholesterolemia causes endothelial dysfunction and cell loss in the retina. Methods. Twelve-month-old apolipoprotein E-deficient (ApoE-/-) mice and age-matched wild-type controls were used in this study (n=8 per genotype for each experiment). Intraocular pressure, blood pressure, and ocular perfusion pressure were determined. Retinal arteriole responses were studied in vitro, and reactive oxygen and nitrogen species were quantified in the retinal and optic nerve cryosections. The expression of the lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1) and the NADPH oxidase isoforms, NOX1, NOX2, and NOX4, were determined in retinal cryosections by immunofluorescence microscopy. Pro- and antioxidant redox genes were quantified in retinal explants by PCR. Moreover, cell number in the retinal ganglion cell layer and axon number in the optic nerve was calculated. Results. Responses to the endothelium-dependent vasodilator, acetylcholine, were markedly impaired in retinal arterioles of ApoE-/- mice (P<0.01). LOX-1 (P=0.0007) and NOX2 (P=0.0027) expressions as well as levels of reactive oxygen species (P=0.0022) were increased in blood vessels but not in other retinal structures. In contrast, reactive nitrogen species were barely detectable in both mouse genotypes. Messenger RNA for HIF-1α, VEGF-A, NOX1, and NOX2, but also for various antioxidant redox genes was elevated in the retina of ApoE-/- mice. Total cell number in the retinal ganglion cell layer did not differ between ApoE-/- and wild-type mice (P=0.2171). Also, axon number in the optic nerve did not differ between ApoE-/- and wild-type mice (P=0.6435). Conclusion. Apolipoprotein E deficiency induces oxidative stress and endothelial dysfunction in retinal arterioles, which may trigger hypoxia in the retinal tissue. Oxidative stress in nonvascular retinal tissue appears to be prevented by the upregulation of antioxidant redox enzymes, resulting in neuron preservation.

22 September 2023 in Diseases
Verified
Journal Article
Open access
PDF file
Francesco BuonfiglioFrancesco Buonfiglio
Francesco Buonfiglio
NXNing Xia
Ning Xia
Can YükselCan Yüksel
Can Yüksel
CMCaroline Manicam
Caroline Manicam
SJSubao Jiang
Subao Jiang
Adrian GerickeAdrian Gericke
Adrian Gericke
Atherogenic lipoproteins may impair vascular reactivity, leading to tissue damage in various organs, including the eye. This study aimed to investigate whether ophthalmic artery reactivity is affected in mice lacking the apolipoprotein E gene (ApoE−/−), a model for hypercholesterolemia and atherosclerosis. Twelve-month-old male ApoE−/− mice and age-matched wild-type controls were used to assess vascular reactivity using videomicroscopy. Moreover, the vascular mechanics, lipid content, levels of reactive oxygen species (ROS), and expression of pro-oxidant redox enzymes and the lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1) were determined in vascular tissue. Unlike the aorta, the ophthalmic artery of ApoE−/− mice developed no signs of endothelial dysfunction and no signs of excessive lipid deposition. Remarkably, the levels of ROS, nicotinamide adenine dinucleotide phosphate oxidase 1 (NOX1), NOX2, NOX4, and LOX-1 were increased in the aorta but not in the ophthalmic artery of ApoE−/− mice. Our findings suggest that ApoE−/− mice develop endothelial dysfunction in the aorta by increased oxidative stress via the involvement of LOX-1, NOX1, and NOX2, whereas NOX4 may participate in media remodeling. In contrast, the ophthalmic artery appears to be resistant to chronic apolipoprotein E deficiency. A lack of LOX-1 expression/overexpression in response to increased oxidized low-density lipoprotein levels may be a possible mechanism of action.

26 March 2021 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
MSMarwin-Jonathan Sähn
Marwin-Jonathan Sähn
Can YükselCan Yüksel
Can Yüksel
SKSebastian Keil
Sebastian Keil
MZMarcel P. Zeisberger
Marcel P. Zeisberger
MPManuel Post
Manuel Post
MSMaximilian Schulze-Hagen
Maximilian Schulze-Hagen
Purpose To determine the performance of radiologists with different levels of expertise regarding the differentiation of COVID-19 from other atypical pneumonias. Chest CT to identify patients suffering from COVID-19 has been reported to be limited by its low specificity for distinguishing COVID-19 from other atypical pneumonias (“COVID-19 mimics”). Meanwhile, the understanding of the morphologic patterns of COVID-19 has improved and they appear to be fairly specific. Materials and Methods Between 02/2020 and 04/2020, 60 patients with COVID-19 pneumonia underwent chest CT in our department. Cases were matched with a comparable control group of 60 patients of similar age, sex, and comorbidities, who underwent chest CT prior to 01/2020 for atypical pneumonia caused by other pathogens. Included were other viral, fungal, and bacterial pathogens. All 120 cases were blinded to patient history and were reviewed independently by two radiologists and two radiology residents. Readers rated the probability of COVID-19 pneumonia according to the COV-RADS classification system. Results were analyzed using Clopper-Pearson 95 % confidence intervals, Youden’s Index for test quality criteria, and Fleiss‘ kappa statistics. Results Overall, readers were able to correctly identify the presence of COVID-19 pneumonia in 219/240 (sensitivity: 91 %; 95 %-CI; 86.9 %–94.5 %), and to correctly attribute CT findings to COVID-19 mimics in 159/240 ratings (specificity: 66.3 %; 59.9 %–72.2 %), yielding an overall diagnostic accuracy of 78.8 % (378/480; 74.8 %–82.3 %). Individual reader accuracy ranged from 74.2 % (89/120) to 84.2 % (101/120) and did not correlate significantly with reader expertise. Youden’s Index was 0.57. Between-reader agreement was moderate (κ = 0.53). Conclusion In this enriched cohort, radiologists were able to distinguish COVID-19 from “COVID-19 mimics” with moderate diagnostic accuracy. Accuracy did not correlate with reader expertise. Key Points: Citation Format

8 May 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
TLTeresa Lemainque
Teresa Lemainque
NPNicola Pridöhl
Nicola Pridöhl
MHMarc Huppertz
Marc Huppertz
MPManuel Post
Manuel Post
Can YükselCan Yüksel
Can Yüksel
Sven NebelungSven Nebelung
Sven Nebelung
Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: “MIX1”, combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and “MIX2”, combining T1-weighted images and T1ρ mapping (6:38 min). MIXTURE sequences and their reference 2D and 3D TSE counterparts were acquired from ten human cadaveric knee joints at 3.0 T. Contrast, contrast-to-noise ratios, and coefficients of variation were comparatively evaluated using parametric tests. Clinical radiologists (n = 3) assessed diagnostic quality as a function of sequence and anatomic structure using five-point Likert scales and ordinal regression, with a significance level of α = 0.01. MIX1 and MIX2 had at least equal diagnostic quality compared to reference sequences of the same image weighting. Contrast, contrast-to-noise ratios, and coefficients of variation were largely similar for the PD-weighted FS and T1-weighted images. In clinically feasible scan times, MIXTURE sequences yield morphologic, TSE-based images of diagnostic quality and quantitative parameter maps with additional insights on soft tissue composition and ultrastructure.

18 July 2022 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
Can YükselCan Yüksel
Can Yüksel
MSMarwin-Jonathan Sähn
Marwin-Jonathan Sähn
MKMichael Kleines
Michael Kleines
JBJörg Christian Brokmann
Jörg Christian Brokmann
CKChristiane K. Kuhl
Christiane K. Kuhl
MSMaximilian Schulze-Hagen
Maximilian Schulze-Hagen
Background So far, typical findings for COVID-19 in computed tomography (CT) have been described as bilateral, multifocal ground glass opacities (GGOs) and consolidations, as well as intralobular and interlobular septal thickening. On the contrary, round consolidations with the halo sign are considered uncommon and are typically found in fungal infections, such as invasive pulmonary aspergillosis. The authors recently observed several patients with COVID-19 pneumonia presenting with round, multifocal consolidations accompanied by a halo sign. As this may indicate alterations of CT morphology based on the virus variant, the aim of this study was to investigate this matter in more detail. Methods 161 CT scans of patients with confirmed SARS-CoV-2 infection (RT-PCR within 2 days of CT) examined between January 2021 and September 15, 2021 were included. Follow-up examinations, patients with invasive ventilation at the time of CT, and patients with insufficient virus typing for variants of concern (VOC) were excluded. CT scans were assessed for vertical and axial distribution of pulmonary patterns, degree of involvement, uni- vs. bilaterality, reticulations, and other common findings. The mean density of representative lesions was assessed in Hounsfield units. Results were compared using Mann-Whitney U-tests, Studentʼs t-rests, descriptive statistics, and Fisher’s exact tests. Results 75 patients did not meet the inclusion criteria. Therefore, 86/161 CT scans of unique patients were analyzed. PCR VOC testing confirmed manifestation of the Delta-VOC SARS-CoV-2 in 22 patients, 39 patients with Alpha-VOC and the remaining 25 patients with Non-VOC SARS-CoV-2 infections. Three patients with the Delta-VOC demonstrated multiple pulmonary masses or nodules with surrounding halo sign, whereas no patients with either Alpha-VOC (p = 0.043) or non-VOC (p = 0.095) demonstrated these findings. All three patients were admitted to normal wards and had no suspicion of a pulmonary co-infection. Patients with Delta-VOC were less likely to have ground glass opacities compared to Alpha-VOC (7/22 or 31.8 % vs. 4/39 or 10.3 %; p < 0.001), whereas a significant difference has not been observed between Delta-VOC and non-VOC (5/25 or 20 %; p = 0.348). The mean representative density of lesions did not show significant differences between the studied cohorts. Conclusion In this study 3 out of 22 patients (13.6 %) with Delta-VOC presented with bilateral round pulmonary masses or nodules with surrounding halo signs, which has not been established as a notable imaging pattern in COVID-19 pneumonia yet. Compared to the other cohorts, a lesser percentage of patients with Delta-VOC presented with ground glass opacities. Based on these results Delta-VOC might cause a divergence in CT-morphologic phenotype. Key Points: Citation Format