The rapid, sensitive, and selective detection of pathogenic bacteria is of utmost importance in ensuring food safety and preventing the spread of infectious diseases. Here, we present a novel, reusable, and cost-effective impedimetric sensor based on a dual bacteria-imprinted polymer (DBIP) for the specific detection of Escherichia coli O157:H7 and Staphylococcus aureus. The DBIP sensor stands out with its remarkably short fabrication time of just 20 min, achieved through the efficient electro-polymerization of o-phenylenediamine monomer in the presence of dual bacterial templates, followed by in-situ template removal. The key structural feature of the DBIP sensor lies in the cavity-free imprinting sites, indicative of a thin layer of bacterial surface imprinting. This facilitates rapid rebinding of the target bacteria within a mere 15 min, while the sensing interface regenerates in just 10 min, enhancing the sensor’s overall efficiency. A notable advantage of the DBIP sensor is its exceptional selectivity, capable of distinguishing the target bacteria from closely related bacterial strains, including different serotypes. Moreover, the sensor exhibits high sensitivity, showcasing a low detection limit of approximately 9 CFU mL−1. The sensor’s reusability further enhances its cost-effectiveness, reducing the need for frequent sensor replacements. The practicality of the DBIP sensor was demonstrated in the analysis of real apple juice samples, yielding good recoveries. The integration of quick fabrication, high selectivity, rapid response, sensitivity, and reusability makes the DBIP sensor a promising solution for monitoring pathogenic bacteria, playing a crucial role in ensuring food safety and safeguarding public health.
Efficient methods for monitoring sulfonamides (SAs) in water and animal-source foods are of great importance to achieve environmental safety and protect human health. Here, we demonstrate a reusable and label-free electrochemical sensor for the rapid and sensitive detection of sulfamethizole based on an electropolymerized molecularly imprinted polymer (MIP) film as the recognition layer. To achieve effective recognition, monomer screening among four kinds of 3-substituted thiophenes was performed by computational simulation and subsequent experimental evaluation, and 3-thiopheneethanol was finally selected. MIP synthesis is very fast and green, and can be in situ fabricated on the transducer surface within 30 min in an aqueous solution. The preparation process of the MIP was characterized by electrochemical techniques. Various parameters affecting MIP fabrication and its recognition response were investigated in detail. Under optimized experimental conditions, good linearity in the range of 0.001−10 μM and a low determination limit of 0.18 nM were achieved for sulfamethizole. The sensor showed excellent selectivity, which can distinguish between structurally similar SAs. In addition, the sensor displayed good reusability and stability. Even after 7 days of storage, or being reused 7 times, higher than 90% of the initial determination signals were retained. The practical applicability of the sensor was also demonstrated in spiked water and milk samples at the nM determination level with satisfactory recoveries. Compared to relevant methods for SAs, this sensor is more convenient, rapid, economical, and eco-friendly, and had comparable or even higher sensitivity, which offered a simple and efficient method for SA detection.
The rapid, sensitive, and selective detection of pathogenic bacteria is of utmost importance in ensuring food safety and preventing the spread of infectious diseases. Here, we present a novel, reusable, and cost-effective impedimetric sensor based on a dual bacteria-imprinted polymer (DBIP) for the specific detection of Escherichia coli O157:H7 and Staphylococcus aureus. The DBIP sensor stands out with its remarkably short fabrication time of just 20 minutes, achieved through the efficient electro-polymerization of o-phenylenediamine monomer in the presence of dual bacterial templates, followed by in-situ template removal. The key structural feature of the DBIP sensor lies in the cavity-free imprinting sites, indicative of a thin layer of bacterial surface imprinting. This facilitates rapid rebinding of the target bacteria within a mere 15 minutes, while the sensing interface regenerates in just 10 minutes, enhancing the sensor's overall efficiency. A notable advantage of the DBIP sensor is its exceptional selectivity, capable of distinguishing the target bacteria from closely related bacterial strains, including different serotypes. Moreover, the sensor exhibits high sensitivity, showcasing a low detection limit of approximately 9 CFU mL-1. The sensor's reusability further enhances its cost-effectiveness, reducing the need for frequent sensor replacements. The practicality of the DBIP sensor was demonstrated in the analysis of real apple juice samples, yielding good recoveries. The integration of quick fabrication, high selectivity, rapid response, sensitivity, and reusability makes the DBIP sensor a promising solution for monitoring pathogenic bacteria, playing a crucial role in ensuring food safety and safeguarding public health.