Xiaojun Bian

Dr. Xiaojun Bian

College of Food Science & Technology, Shanghai Ocean University, Shanghai 201306, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Talanta
Verified
Journal Article
Closed access
RWRuinan Wang
Ruinan Wang
LWLingling Wang
Lingling Wang
JYJuan Yan
Juan Yan
DLDonglei Luan
Donglei Luan
TSTao Sun
Tao Sun
XBXiaojun Bian
Xiaojun Bian

3 December 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
JWJikui Wu
Jikui Wu
RWRuinan Wang
Ruinan Wang
YLYunfei Lu
Yunfei Lu
MJMin Jia
Min Jia
JYJuan Yan
Juan Yan
XBXiaojun Bian
Xiaojun Bian

24 March 2023 in Analytical Chemistry
Verified
Journal Article
Closed access
XLXiaohui Lin
Xiaohui Lin
PLPing Ping Liu
Ping Ping Liu
Juan YanJuan Yan
Juan Yan
DLDonglei Luan
Donglei Luan
TSTao Sun
Tao Sun
XBXiaojun Bian
Xiaojun Bian

8 May 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
YMYixin Ma
Yixin Ma
XLXiaohui Lin
Xiaohui Lin
BXBin Xue
Bin Xue
DLDonglei Luan
Donglei Luan
CJChunping Jia
Chunping Jia
JZJianlong Zhao
Jianlong Zhao

3 September 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
XXXiaoli Xu
Xiaoli Xu
XLXiaohui Lin
Xiaohui Lin
LWLingling Wang
Lingling Wang
YMYixin Ma
Yixin Ma
TSTao Sun
Tao Sun
XBXiaojun Bian
Xiaojun Bian
The rapid, sensitive, and selective detection of pathogenic bacteria is of utmost importance in ensuring food safety and preventing the spread of infectious diseases. Here, we present a novel, reusable, and cost-effective impedimetric sensor based on a dual bacteria-imprinted polymer (DBIP) for the specific detection of Escherichia coli O157:H7 and Staphylococcus aureus. The DBIP sensor stands out with its remarkably short fabrication time of just 20 min, achieved through the efficient electro-polymerization of o-phenylenediamine monomer in the presence of dual bacterial templates, followed by in-situ template removal. The key structural feature of the DBIP sensor lies in the cavity-free imprinting sites, indicative of a thin layer of bacterial surface imprinting. This facilitates rapid rebinding of the target bacteria within a mere 15 min, while the sensing interface regenerates in just 10 min, enhancing the sensor’s overall efficiency. A notable advantage of the DBIP sensor is its exceptional selectivity, capable of distinguishing the target bacteria from closely related bacterial strains, including different serotypes. Moreover, the sensor exhibits high sensitivity, showcasing a low detection limit of approximately 9 CFU mL−1. The sensor’s reusability further enhances its cost-effectiveness, reducing the need for frequent sensor replacements. The practicality of the DBIP sensor was demonstrated in the analysis of real apple juice samples, yielding good recoveries. The integration of quick fabrication, high selectivity, rapid response, sensitivity, and reusability makes the DBIP sensor a promising solution for monitoring pathogenic bacteria, playing a crucial role in ensuring food safety and safeguarding public health.

12 August 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
LWLingling Wang
Lingling Wang
XLXiaohui Lin
Xiaohui Lin
TLTing Liu
Ting Liu
ZZZhaohuan Zhang
Zhaohuan Zhang
JKJie Kong
Jie Kong
XBXiaojun Bian
Xiaojun Bian
A bacteria-imprinted polythiophene film (BIF)-based impedimetric sensor was proposed for the rapid and sensitive detection ofS. aureus. A significant improvement is the reduced time for both BIF fabrication (15 min) and bacterial capturing (10 min).