The use of adhesives and metal connectors is vital in engineered wood product (EWP) composition. However, the utilization of adhesives poses sustainability and recyclability challenges due to the emission of toxic gases. Similarly, metal fasteners negatively impact the disposal, reusability, and recyclability of EWPs. An alternative solution that exclusively employs pure wood, known as dovetail massive wooden board elements (DMWBEs), eliminates the need for adhesives and metal fasteners. This paper presents an experimental comparative assessment of the fire/charring performance of DMWBEs and cross-laminated timber (CLT). Model-scale test specimens measuring 200 mm in thickness, 950 mm in width, and 950 mm in length were vertically tested according to EN 1363-1. The charring behavior of DMWBEs closely resembled that of solid timber, with only a slight increase in the charring rate. Charring primarily occurred in the third lamella layer out of five, with no observable flames or hot gases on the unexposed side. The dovetail detail effectively prevented char fall-off with the tested lamella thickness. CLT specimens exhibited a notable rise in the charring rate due to the fall-off of the first lamellae layer.
1 March 2018 in Journal of Constructional Steel Research
A large number of fires have been caused by metal chimney penetrations in recent years. One factor that has contributed to these occurrences is smouldering combustion within mineral wool, which is often used as insulation in metal chimneys and their penetrations. Based on reaction to fire performance mineral wool is typically classified as a non-combustible material and in European standards it belongs to category Euroclass A1. However, mineral wool insulation products contain organic material, which smoulders and generates heat at temperatures between 200°C and 500°C. Experimental research indicates that this additional heat may increase the temperature in the chimney penetration materials over 100°C for a limited period of time. The European fire classification of materials does not set requirements to control mineral wool smouldering and limit the subsequent heat release. This experimental study examined the smouldering of mineral wool insulation products specified for chimney penetrations and the heat release generated during the smouldering combustion. The aim of the study was to determine the actual level of temperature increase within the chimney penetration and to estimate the effects of the increase with regard to fire safety. The study also reviewed how the smouldering potential of an insulation material could be considered in the fire classification of products.