The use of adhesives and metal connectors is vital in engineered wood product (EWP) composition. However, the utilization of adhesives poses sustainability and recyclability challenges due to the emission of toxic gases. Similarly, metal fasteners negatively impact the disposal, reusability, and recyclability of EWPs. An alternative solution that exclusively employs pure wood, known as dovetail massive wooden board elements (DMWBEs), eliminates the need for adhesives and metal fasteners. This paper presents an experimental comparative assessment of the fire/charring performance of DMWBEs and cross-laminated timber (CLT). Model-scale test specimens measuring 200 mm in thickness, 950 mm in width, and 950 mm in length were vertically tested according to EN 1363-1. The charring behavior of DMWBEs closely resembled that of solid timber, with only a slight increase in the charring rate. Charring primarily occurred in the third lamella layer out of five, with no observable flames or hot gases on the unexposed side. The dovetail detail effectively prevented char fall-off with the tested lamella thickness. CLT specimens exhibited a notable rise in the charring rate due to the fall-off of the first lamellae layer.
Slim-floor-type of steel-timber hybrid floor systems which use steel beams contained within the depth of the cross-laminated timber (CLT) floor slab offer many benefits, but there is still very little research available on the fire resistance performance of these systems. In the study presented in this paper two furnace tests and numerical simulations have been conducted to investigate the thermal profiles of the steel member and CLT slabs and to obtain information on the temperature development and charring of the hybrid beam section when it is exposed to standard fire conditions. Also, the effects of intumescent fire protection on temperatures and charring performance were investigated. Numerical 2D thermal simulations for unprotected and protected cases were conducted using SAFIR software, and the agreement between experiments and numerical-analysis predictions were in general very good. The results show that intumescent protection reduces the temperatures of the steel and CLT components as well as charring depth significantly, and the start of charring at CLT slab support may be delayed if intumescent paint protection thicker than that required for the load bearing steel member is used. The result also showed that CLT temperatures exceed 100°C already in the early stages of the fire which decrease the strength and stiffness properties of CLT much before the start of charring. Therefore, the fire design of the CLT slab support should not only consider the char depth and residual cross-section analysis but also the reduction in strength.
Recent design guides include charring models for cross-laminated plane timber (CLT) members. When the bond line integrity is not maintained, charring is illustrated as a combination of sequenced phases. Significant research has been conducted on the charring behaviour of CLT panels, and the criterion of 300 °C has been an accepted definition for the char front line. The charring rate of a solid wood-based panel is determined by the char depth divided by the time to reach the char depth. In the CLT structure, this method can be applied to the first lamella layer. However, due to the char fall-off, it cannot be directly applied to the lamella layers behind the first layer. In this research, eight fire tests were conducted to investigate how charring rates of different lamella layers can be determined from measured temperatures. An assessment method based on the mean char depth development determined from experimental temperature distributions of CLT panels is introduced. Also, the effects of thermocouple positioning and specimen orientation on the assessment results were analysed. The charring rates determined for both horizontal and vertical specimens align well with the results calculated using the European Charring Model and a post-protection factor k3 of 2.
This paper presents a description and the analysis of a fire test on a cellular beam made from grade 1.4301 stainless steel. Cellular beams are increasingly popular in the construction as they provide a structurally and materially efficient design solution as well as allowing the passage of services. In addition, stainless steel is also increasing in popularity for structural applications owing to its inherent durability and ductility, as well as other attractive properties such as structural efficiency and low maintenance requirements. However, the behaviour of stainless steel cellular beams in fire has received little attention from the research community until recently. In the current paper, a description is presented of an experimental investigation into the fire behaviour of grade 1.4301 stainless steel cellular beams. The experimental arrangements are described together with the details of the specimen. The test occurred at the fire testing laboratory at Tampere University, Finland. For the member test, the beam spanned 4,3 m, with an overall depth of 290 mm and 200 mm diameter openings along the span. It was found that the unprotected beam lasted for 29 minutes during the test, after being exposed to a standard fire, and the experiment was eventually stopped due to excessive rate of deflection. The test specimen has been analysed using available design methods and the results are presented herein.
Previous research have demonstrated that significant cost savings can be achieved, if cladding panels forming the building envelope are used to provide stability. There is research information and design guidance available for normal temperature design. However, the information available for fire conditions is very limited and it is not known if the panels are able to stabilize steel frame members also at elevated temperatures. The stiffness and resistance of joints, cladding panels and connectors are required for the assessment of interaction between cladding and frame in fire. Temperatures of those components are in important role when evaluating the stabilization effect. This paper presents an experimental research conducted to determine the temperature fields in sandwich panels, supporting structural steel members and screw connectors. Eight full-scale fire tests were carried out where the structural steel sections supporting sandwich panels were exposed to ISO 834 fire attack on three sides. The test specimen consisted of a fire protected steel beam and load-bearing sandwich panels with both mineral wool and polyisocyanurate (PIR) core. Two different steel beam sections were used in the tests: HEA 160 (S355) and RHS 150×150x8 (S420). This paper introduces the experimental research and the main observations related to the temperatures. The results show that at failure of the specimens the measured screw temperatures were very different in HEA and RHS tests. The temperatures in HEA tests were much higher than in RHS tests the maximum difference in screw point temperatures being over 400°C. In all the specimens, screw head temperatures were very low throughout the tests, well below 100°C. The tests were part of ongoing RFCS project STABFI.