João Pedro Santos

Mr. João Pedro Santos

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2024 in Chemical Engineering Journal
Verified
Journal Article
Open access
LMLucca Matuck
Lucca Matuck
JSJoão Pedro Santos
João Pedro Santos
FFFábio Freitas
Fábio Freitas
LFLuís B. Fontes
Luís B. Fontes
JBJörg Bierlich
Jörg Bierlich
MNMicael Nascimento
Micael Nascimento

8 September 2023 in Photonics
Verified
Journal Article
Open access
PDF file
JSJoão Pedro Santos
João Pedro Santos
JBJörg Bierlich
Jörg Bierlich
JKJens Kobelke
Jens Kobelke
MFMarta Ferreira
Marta Ferreira
A hybrid fiber sensor for the simultaneous measurement of pressure and temperature is proposed. The sensor is constituted of a section of silica capillary tube (SCT) whereat access channels are created with two different methods: instilling a bubble on the fiber by employing successive arc discharges on the SCT whilst under pressure and splicing the SCT with another section of SCT with a smaller inner diameter. The reflection-based sensor enhances Fabry–Perot interference (FPI) and antiresonant (AR) guidance, simultaneously, in a single sensing element of a few millimeters. A comparison study between the access channel methods reveals higher spectral visibility for the bubble method and similar pressure and temperature resolutions. For a 2.58 mm long sensor with a bubble, the sensitivity to pressure is 4.09 ± 0.01 nm/MPa and −3.7 ± 0.1 nm/MPa for the FPI and AR, respectively, while its sensitivity to temperature is −0.20 ± 0.02 pm/°C and 24.0 ± 0.5 pm/°C, respectively, for the FPI and AR, which are within the numerically calculated sensitivities. The sensor is robust and has a convenient reflective probe with easy and low-cost fabrication, granting high competitiveness in actual applications.

26 February 2025 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JSJoão Pedro Santos
João Pedro Santos
DPDiana Pereira
Diana Pereira
RARaquel Augusto
Raquel Augusto
JBJörg Bierlich
Jörg Bierlich
MNMicael Nascimento
Micael Nascimento
MFMarta Ferreira
Marta Ferreira
A multiparameter sensor based on a single section of a hollow square core fiber (HSCF) spliced between a single mode fiber and a silica capillary tube is proposed. In a reflection scheme, several Fabry-Perot (FP) cavities are enhanced in different areas of the HSCF. In a 439 μm long sensing head, three FP cavities are excited. Using the Fourier band-pass filter method, each cavity is individually monitored towards the measurand variation. The distinct responses of the FP cavities allow for a hybrid application for simultaneous measurement of pressure, temperature, and curvature. Additionally, a sinusoidal behavior is found in the curvature response when bending is applied for different relative positions of the fiber. The proposed sensor is robust with simple fabrication and small dimensions, demonstrating promising potential for applications where the simultaneous measurement of several physical parameters is required.

1 December 2022 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
JSJoão Pedro Santos
João Pedro Santos
JBJörg Bierlich
Jörg Bierlich
JKJens Kobelke
Jens Kobelke
MFMarta S Ferreira
Marta S Ferreira
In this work, a hybrid sensor based on a silica capillary in a balloon-like shape for simultaneous measurement of displacement and temperature is proposed for the first time, to the best of our knowledge. The sensor is fabricated by splicing a segment of a hollow core fiber between two single mode fibers (SMF) and by bending the fiber in a balloon shape with the capillary at the top-center position. In a transmission scheme, the SMF-capillary-SMF configuration excites an antiresonant (AR) guidance and the balloon shape enhances a Mach-Zehnder interferometer (MZI). The different responses of the interferometers to external displacement and temperature variations are conducive to a hybrid application of the sensor for simultaneous measurement of these parameters. Experimental results show that, for a capillary length of 1.2 cm and a balloon length of 4 cm, AR is insensitive to displacement and its sensitivity to temperature is 14.3 pm/°C, while the MZI has a sensitivity to displacement of 1.68 nm/mm and twice the sensitivity of AR to temperature, of 28.6 pm/°C. The proposed fiber sensor consists of only one sensing element in one configuration exciting two interferometers at the same time, which makes it of simple fabrication as well as low cost.

30 July 2026 in Optics & Laser Technology
Verified
Journal Article
Open access
JSJoão Pedro Santos
João Pedro Santos
JMJeroen Missinne
Jeroen Missinne
MNMicael Nascimento
Micael Nascimento
MFMarta Ferreira
Marta Ferreira