Marta Ferreira

Dr. Marta Ferreira

Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Aveiro, Portugal
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Power Sources
Verified
Journal Article
Closed access
MNMicael Nascimento
Micael Nascimento
SNSusana Novais
Susana Novais
MDMarkus S. Ding
Markus S. Ding
MFMarta Ferreira
Marta Ferreira
SKStephan Koch
Stephan Koch
JPJoão L. Pinto
João L. Pinto

9 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndré Gomes
André Gomes
MFMarta Ferreira
Marta Ferreira
JBJörg Bierlich
Jörg Bierlich
JKJens Kobelke
Jens Kobelke
MRManfred Rothhardt
Manfred Rothhardt
Orlando FrazãoOrlando Frazão
Orlando Frazão
The optical Vernier effect magnifies the sensing capabilities of an interferometer, allowing for unprecedented sensitivities and resolutions to be achieved. Just like a caliper uses two different scales to achieve higher resolution measurements, the optical Vernier effect is based on the overlap in the responses of two interferometers with slightly detuned interference signals. Here, we present a novel approach in detail, which introduces optical harmonics to the Vernier effect through Fabry–Perot interferometers, where the two interferometers can have very different frequencies in the interferometric pattern. We demonstrate not only a considerable enhancement compared to current methods, but also better control of the sensitivity magnification factor, which scales up with the order of the harmonics, allowing us to surpass the limits of the conventional Vernier effect as used today. In addition, this novel concept opens also new ways of dimensioning the sensing structures, together with improved fabrication tolerances.


1 June 2012 in Solar Energy Materials and Solar Cells
Verified
Journal Article
Closed access
Pedro SaloméPedro Salomé
Pedro Salomé
JMJ. Malaquias
J. Malaquias
PFP.A. Fernandes
P.A. Fernandes
MFMarta Ferreira
Marta Ferreira
ACAntonio Cunha
Antonio Cunha
FMF.M. Matinaga
F.M. Matinaga

7 October 2011 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MFMarta Ferreira
Marta Ferreira
Luís C. C. CoelhoLuís C. C. Coelho
Luís C. C. Coelho
KSKay Schuster
Kay Schuster
JKJens Kobelke
Jens Kobelke
JSJosé Luís Santos
José Luís Santos
Orlando FrazãoOrlando Frazão
Orlando Frazão
A Fabry–Perot (FP) cavity of simple design and based on a pure silica diaphragm-free hollow tube is proposed. Its operation is based on a first reflection of light at the end of the single-mode fiber that illuminates the silica rod and in a second reflection that takes place at the end of the rod. The FP cavity is characterized for high temperature, pressure and refractive index sensing, showing useful characteristics for the measurement of these three parameters. The diaphragm-free configuration simplifies the measurement of the refractive index of fluids.

11 September 2012 in Optics Express
Verified
Journal Article
Open access
PDF file
MFMarta Ferreira
Marta Ferreira
JBJörg Bierlich
Jörg Bierlich
JKJens Kobelke
Jens Kobelke
KSKay Schuster
Kay Schuster
JSJosé Luís Santos
José Luís Santos
Orlando FrazãoOrlando Frazão
Orlando Frazão
A high sensitivity Fabry-Pérot (FP) strain sensor based on hollow-core ring photonic crystal fiber was investigated. A low-finesse FP cavity was fabricated by splicing a section of hollow-core ring photonic crystal fiber between two standard single mode fibers. The geometry presents a low cross section area of silica enabling to achieve high strain sensitivity. Strain measurements were performed by considering the FP cavity length in a range of 1000 μm. The total length of the strain gauge at which strain was applied was also studied for a range of 900 mm. The FP cavity length variation highly influenced the strain sensitivity, and for a length of 13 μm a sensitivity of 15.4 pm/με was attained. Relatively to the strain gauge length, its dependence to strain sensitivity is low. Finally, the FP cavity presented residual temperature sensitivity (~0.81 pm/°C).