Bert Coolen

Mr. Bert Coolen

Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DGDaphne Geerse
Daphne Geerse
BCBert Coolen
Bert Coolen
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.

5 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DGDaphne Geerse
Daphne Geerse
BCBert Coolen
Bert Coolen
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
Microsoft’s HoloLens, a mixed-reality headset, provides, besides holograms, rich position data of the head, which can be used to quantify what the wearer is doing (e.g., walking) and to parameterize such acts (e.g., speed). The aim of the current study is to determine test-retest reliability, concurrent validity, and face validity of HoloLens 1 for quantifying spatiotemporal gait parameters. This was done in a group of 23 healthy young adults (mean age 21 years) walking at slow, comfortable, and fast speeds, as well as in a group of 24 people with Parkinson’s disease (mean age 67 years) walking at comfortable speed. Walking was concurrently measured with HoloLens 1 and a previously validated markerless reference motion-registration system. We comprehensively evaluated HoloLens 1 for parameterizing walking (i.e., walking speed, step length and cadence) in terms of test-retest reliability (i.e., consistency over repetitions) and concurrent validity (i.e., between-systems agreement), using the intraclass correlation coefficient (ICC) and Bland–Altman’s bias and limits of agreement. Test-retest reliability and between-systems agreement were excellent for walking speed (ICC ≥ 0.861), step length (ICC ≥ 0.884), and cadence (ICC ≥ 0.765), with narrower between-systems than over-repetitions limits of agreement. Face validity was demonstrated with significantly different walking speeds, step lengths and cadences over walking-speed conditions. To conclude, walking speed, step length, and cadence can be reliably and validly quantified from the position data of the wearable HoloLens 1 measurement system, not only for a broad range of speeds in healthy young adults, but also for self-selected comfortable speed in people with Parkinson’s disease.

17 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BCBert Coolen
Bert Coolen
Peter BeekPeter Beek
Peter Beek
DGDaphne Geerse
Daphne Geerse
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
Mixed-reality technologies are evolving rapidly, allowing for gradually more realistic interaction with digital content while moving freely in real-world environments. In this study, we examined the suitability of the Microsoft HoloLens mixed-reality headset for creating locomotor interactions in real-world environments enriched with 3D holographic obstacles. In Experiment 1, we compared the obstacle-avoidance maneuvers of 12 participants stepping over either real or holographic obstacles of different heights and depths. Participants’ avoidance maneuvers were recorded with three spatially and temporally integrated Kinect v2 sensors. Similar to real obstacles, holographic obstacles elicited obstacle-avoidance maneuvers that scaled with obstacle dimensions. However, with holographic obstacles, some participants showed dissimilar trail or lead foot obstacle-avoidance maneuvers compared to real obstacles: they either consistently failed to raise their trail foot or crossed the obstacle with extreme lead-foot margins. In Experiment 2, we examined the efficacy of mixed-reality video feedback in altering such dissimilar avoidance maneuvers. Participants quickly adjusted their trail-foot crossing height and gradually lowered extreme lead-foot crossing heights in the course of mixed-reality video feedback trials, and these improvements were largely retained in subsequent trials without feedback. Participant-specific differences in real and holographic obstacle avoidance notwithstanding, the present results suggest that 3D holographic obstacles supplemented with mixed-reality video feedback may be used for studying and perhaps also training 3D obstacle avoidance.


10 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
DGDaphne Geerse
Daphne Geerse
BCBert Coolen
Bert Coolen
DKDetmar Kolijn
Detmar Kolijn
Melvyn RoerdinkMelvyn Roerdink
Melvyn Roerdink
The Kinect v2 sensor may be a cheap and easy to use sensor to quantify gait in clinical settings, especially when applied in set-ups integrating multiple Kinect sensors to increase the measurement volume. Reliable estimates of foot placement locations are required to quantify spatial gait parameters. This study aimed to systematically evaluate the effects of distance from the sensor, side and step length on estimates of foot placement locations based on Kinect’s ankle body points. Subjects (n = 12) performed stepping trials at imposed foot placement locations distanced 2 m or 3 m from the Kinect sensor (distance), for left and right foot placement locations (side), and for five imposed step lengths. Body points’ time series of the lower extremities were recorded with a Kinect v2 sensor, placed frontoparallelly on the left side, and a gold-standard motion-registration system. Foot placement locations, step lengths, and stepping accuracies were compared between systems using repeated-measures ANOVAs, agreement statistics and two one-sided t-tests to test equivalence. For the right side at the 2 m distance from the sensor we found significant between-systems differences in foot placement locations and step lengths, and evidence for nonequivalence. This distance by side effect was likely caused by differences in body orientation relative to the Kinect sensor. It can be reduced by using Kinect’s higher-dimensional depth data to estimate foot placement locations directly from the foot’s point cloud and/or by using smaller inter-sensor distances in the case of a multi-Kinect v2 set-up to estimate foot placement locations at greater distances from the sensor.

1 January 2003 in Journal of Sports Sciences
Verified
Journal Article
Closed access
RORaôul Oudejans
Raôul Oudejans
BCBert Coolen
Bert Coolen
In human movement and sports science, manipulations of perception and action are common and often comprise the control of events, such as opening or closing liquid crystal goggles. Most of these events are externally controlled, independent of the actions of the participants. Less common, although sometimes desirable, are event manipulations that are dependent on the unconstrained movements of participants. As an example, we describe a method we used previously to manipulate vision of basketball jump shooters on the basis of on-line registration of their own movements. The shooters wore liquid crystal goggles that opened or shut as a function of specific kinematic features of these movements. The novel aspect of this method is that the criteria for detecting movement patterns and performing the appropriate manipulations are adjustable to the specific sport context and the complexity and variations of the unconstrained movements. The method was implemented as a finite state machine: a computer system that can be used for pattern recognition. We discuss this method, how it works and the potential it has for studying perceptual-motor skills in sport. Furthermore, the results of the basketball experiment are briefly summarized and complemented with new analyses.