Music is a complex phenomenon with multiple brain areas and neural connections being implicated. Centuries ago, music was discovered as an efficient modality for psychological status enrichment and even for the treatment of multiple pathologies. Modern research investigations give a new avenue for music perception and the understanding of the underlying neurological mechanisms, using neuroimaging, especially magnetic resonance imaging. Multiple brain areas were depicted in the last decades as being of high value for music processing, and further analyses in the neuropsychology field uncover the implications in emotional and cognitive activities. Music listening improves cognitive functions such as memory, attention span, and behavioral augmentation. In rehabilitation, music-based therapies have a high rate of success for the treatment of depression and anxiety and even in neurological disorders such as regaining the body integrity after a stroke episode. Our review focused on the neurological and psychological implications of music, as well as presenting the significant clinical relevance of therapies using music.
Glaucoma is a vision threatening, not uncommon complication of eyes that have undergone pars plana vitrectomy with silicone oil endotamponade. Although most patients respond well to medical antiglaucoma therapy, there are refractory cases where surgery is required to control the intraocular pressure. This review, following a comprehensive literature search in the Medline database, aims to present the most important surgical techniques currently in use for glaucoma associated with silicone oil endotamponade and their indication depending on the mechanism of glaucoma. In cases of pupillary block, the presence of a patent iridotomy or iridectomy must be ensured, either by laser or surgically. When silicone oil is in excess and whenever the retinal status permits it, partial or complete removal of the silicone oil should be performed. Trabeculectomy has shown higher failure rates and more complications in these cases compared to other indications, so alternate methods are warranted. For very high intraocular pressures, glaucoma drainage devices and transscleral cyclophotocoagulation are the most used options, with good efficacy and safety profiles, although rarely they may have serious complications. The Ex-PRESS mini shunt has shown excellent results and lower rates of complications. For less important IOP elevations, minimally invasive glaucoma surgery and selective laser trabeculoplasty may be used, either alone or in conjunction with other methods.
The main objective of the article was to assess the surgical outcome of micropulse transscleral cyclophotocoagulation in patients presenting with glaucoma after penetrating keratoplasty. We conducted a retrospective study that included 26 eyes of 26 patients who presented with glaucoma after penetrating keratoplasty, and who were treated using micropulse transscleral cyclophotocoagulation between January 2017 and December 2020. The surgeries were performed using the Iridex Cyclo G6 MicroPulse P3 Probe. The intraocular pressure, mean number of antiglaucoma medications, visual acuity, corneal status, and postoperative complications were analyzed. The minimum follow-up period was 12 months. The success rate after 12 months was 76.9%. The baseline median intraocular pressure was 29 mm Hg and decreased to 18 mm Hg after 12 months. The median number of antiglaucoma medications was also reduced from three preoperatively to one after one year. In seven cases (29.92%), the visual acuity decreased and, in four cases (15.38%), the corneal graft was not transparent. We concluded that micropulse transscleral cyclophotocoagulation is an effective and safe method for the treatment of glaucoma after penetrating keratoplasty.
(1) Background: Laser-assisted refractive surgery is a safe and effective surgical correction of refractive error. For most patients, both the newer Trans-PRK and the established LASIK technique can produce the required surgical correction, sparking the question of which technique should be opted for. (2) Methods: The study prospectively evaluated 121 patients (230 eyes) for at least one month postoperatively; 66 patients (126 eyes) and 45 patients (85 eyes) returned for 6 months and 1 year follow-up. (3) Results: No statistical difference was recorded at 1 week or 1 month post-operation. At 6 months, a difference was found for spherical diopters (Trans-PRK −0.0476 ± 0.7012 versus FS-LASIK +0.425 ± 0.874, p = 0.004) and spherical equivalent (Trans-PRK −0.1994 ± 0.0294 versus FS-LASIK +0.225 ± 0.646, p = 0.025) but not for CYL D (Trans-PRK −0.3036 ± 0.5251 versus FS-LASIK −0.4 ± 0.820, p = 0.499). Uncorrected visual acuity was better for Trans-PRK 6 months post-operation (UCVA logMAR 0.02523 versus 0.0768 logMAR; p = 0.015 logMAR). At 1-year, Trans-PRK was favored for spherical diopters (Trans-PRK −0.0294 ± 0.6493 versus FS-LASIK +0.646 ± 0.909, p < 0.001) and spherical equivalent (Trans-PRK −0.218 ± 0.784 versus FS-LASIK 0.372 ± 1.08, p = 0.007). Overall speed in visual recovery, variance of results and surgically induced astigmatism were in favor of Trans-PRK. (4) Conclusions: The study reported improvements for Trans-PRK patients, with both techniques found to be safe and effective.
1 January 2016 in Acta Endocrinologica (Bucharest)
Memory deficits, anxiety and depression are often associated with diabetes, worsening diabetic patients' prognosis. Caffeine, a worldwide used psychoactive substance, is a candidate for improving these conditions. The aim of this study was to assess the behaviour in streptozotocin-induced diabetic Wistar rats and to evaluate the behavioural effects of caffeine administration. Diabetes was induced by a single intraperitoneal injection of 50 mg/kg BW streptozotocin (n=10), while control rats received the vehicle (n=9). After six weeks, behavioural tests for anxiety, memory and depression were performed: elevated plus maze (EPM) test, novel object recognition (NOR) test and forced swimming test (FST), respectively. The tests were repeated after further 2 weeks of continuous caffeine administration (20 mg/kg BW/day in drinking water). Diabetic rats manifested a high anxiety level, showed by a reduced exploratory activity compared to control rats (p<0.05) and long-term memory impairment, spending more time near the old object in NOR test. Caffeine administered for 2 weeks did not modify glycemic values in either group, and attenuated the behavioural changes observed in the EPM test. Also, in NOR test for long-term memory, caffeine administration induced an increased time spent with the novel object than with the old one in both groups. Our data suggest that chronic caffeine administration has an anxiolytic effect in diabetic rats and improves long-term memory in both diabetic and control rats.
Background and Clinical Significance: To our knowledge, there is a lack of electron microscopy studies in hematocornea since 1985, and more so for graft hematocornea after deep anterior lamellar keratoplasty (DALK). This study provides an ultrastructural characterization of hematocornea occurring in a DALK graft. Our study presents several limitations: single-case design and lack of control tissue. Case Presentation: The DALK graft with hematocornea was excised and introduced inside of the operating room in glutaraldehyde solution recipient. The graft was quickly cold-transported to light and transmission electron microscopy. Hematocornea in the DALK transplant graft resulted in features of stromal alteration and dysfunctional cellular clean-up response. The collagen lamellae ultrastructure was affected near electron-dense hem deposits. Two cellular aspects were observed: adaptation and degeneration. Electron-dense granules were found in keratocytes, which may exhibit cellular adaptations, such as vacuoles and phagosomes. Macropinocytosis may mechanistically explain ingestion of electron-dense granules, and dysfunctions in the macropinocytosis process may have led to cell degeneration. Cellular degeneration was marked by loss of organelle contour and loss of cellular membrane integrity (burst-cell aspect). Microscopic corneal alteration corresponded to macroscopic total loss of corneal transparency and elasticity. Conclusions: This study described lamellar ultrastructure alterations and dysfunctional cellular response in hematocornea of a DALK corneal transplant graft.