Congqi Fang

Congqi Fang

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
ZYZhijie Yuan
Zhijie Yuan
CFCongqi Fang
Congqi Fang
MPMohammad Parsaeimaram
Mohammad Parsaeimaram
SYShuai Yang
Shuai Yang
Corrosion damage is one of the main problems affecting the durability of concrete structures. Several corroded reinforced concrete (RC) railway bridges are located in regions of high seismic risk. Corroded bridge piers are often subjected to dynamic axial loads, such as the vertical pounding that occurs during earthquakes or due to railway trains. Repeated axial loading was used to simulate this vertical pounding effect. Therefore, the seismic performance of corroded RC structures under repeated axial and horizontal cyclic loading is an urgent issue. To investigate the influences of steel corrosion and repeated axial loading on the seismic performance of a column pier, eight RC column specimens were experimentally investigated. The results indicated that corrosion significantly influences the yield strength and load bearing capacity of a column. The load bearing capacities of the corroded specimens decreased by 18.27% compared with noncorroded specimens when the longitudinal loss of steel mass was 7.16%. Repeated axial loading did not significantly influence the mechanical properties of the corroded RC piers. Cyclic tests were performed to validate a finite-element model that was used to assess the effects of corrosion level on the seismic performance of columns. The level of steel corrosion ranged from 0 to 28%. According to the finite-element analysis, the yield strength (35%) and ultimate displacement (34%) decreased with increasing corrosion.

1 August 2015 in Advances in Structural Engineering
Verified
Journal Article
Closed access
SYS. Yang
S. Yang
CFCongqi Fang
Congqi Fang
ZYZ.J. Yuan
Z.J. Yuan
MYM.Y. Yi
M.Y. Yi
The effects of both steel corrosion and repeated loading on performance of reinforced concrete beam were investigated. Repeated loads were applied to corroded reinforced concrete specimens with corrosion levels ranging from 0% to 5%. The experiments were conducted for the deflection, cracking, stiffness, bearing capacity and failure type of the corroded beams. For corrosion levels less than 5%, the residual deflection was about 3% of the maximum value of failure deflection. The deflection of beams of high corrosion levels were generally greater than those of low corrosion levels, while the flexural rigidity of the high corrosion levels decreased more in value than those of low corrosion levels. The failure modes of beams changed from plastic type to brittle type with the increase of corrosion level.

14 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
WDWenyan Dong
Wenyan Dong
CFCongqi Fang
Congqi Fang
RHRan Hu
Ran Hu
The self-leveling mortar (SLM) of a ternary cementitious system with different dosages of redispersible powder (RP) with ordinary Portland cement (OPC), sulfoaluminate cement (SAC), and calcium sulfate (CS) as cementitious materials was investigated with regard to fluidity, bond strength, shrinkage rate, abrasion resistance, flexural strength, and compressive strength. The performance parameters obtained from the experimental test for SLM were weighted values calculated with an analytic hierarchy process (AHP). The comprehensive index of performance was evaluated on the basis of a weighted-sum method, and the optimal dosage of RP was determined according to the comprehensive index. The experimental results demonstrated that the fluidity of SLM decreased with the increase in RP dosage at the beginning but then increased thereafter and decreased rapidly as the dosage went beyond 3.0%. The addition of RP resulted in a significant improvement in bond strength (of SLM), reduction in the shrinkage rate, abrasion loss, early flexural strength and compressive strength, and resistance to cracking. The properties of SLM with 3.0% RP can meet the requirements of the industrial standard for cementitious self-leveling floor mortar. Compared with the SLM without RP, the bond strength of SLM with 3.0% RP was increased by 46.7%, while the shrinkage rate and abrasion loss were reduced by 50% and 71.9% respectively. The weighted values of fluidity, compressive strength, flexural strength, stability, cohesiveness, and abrasion resistance were 0.422, 0.196, 0.196, 0.089, 0.058, and 0.039, respectively. A higher value of the comprehensive index generally denotes a better performance. The comprehensive index of SLM with 3.0% RP was the highest.

1 January 2018 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
MPMohammad Parsaeimaram
Mohammad Parsaeimaram
CFCongqi Fang
Congqi Fang
XLXianqi Luo
Xianqi Luo
CSChandan Shakya
Chandan Shakya
Base isolation is a widely accepted earthquake damage prevention technique. This method decouples the superstructure from the base by putting a flexible layer under each column, thereby elongating the time period of structures. Semi‐base isolation (SBI) in double‐skin structures is an effective technique to reduce the dynamic responses of structures due to earthquake motions, by utilizing the isolation devices in part of it instead of the entire base. This study presents a double‐skin structure consisting of outer fixed base frames with shear walls that have been detached from the inner core with a minor gap. The inner core of the structure has been dissociated from the base using the elastomeric bearings. Seismic response of 10‐story double‐skin structure with inner isolated core was compared to that of inner fixed base core to consider the yielding and collapse probability of the structure using the incremental dynamic analyses (IDA). The results showed that the time period in SBI buildings can be adjusted with the use of coupling beams between the inner and outer frames. Also, the time period and interstory drift ratio are both reduced as more floors are given coupling beams. However, these coupling beams are the most effective at the topmost floors.

1 December 2017 in Proceedings of the Institution of Civil Engineers - Bridge Engineering
Verified
Journal Article
Closed access
CFCongqi Fang
Congqi Fang
ZYZhijie Yuan
Zhijie Yuan
SYShuai Yang
Shuai Yang
JZJunmeng Zhang
Junmeng Zhang
The presence of chloride ions causes reinforced-concrete (RC) bridge piers in a corrosive environment to suffer from different degrees of corrosion damage. Investigation of the seismic performance of corroded RC bridge piers using cyclic loading is therefore of great value. In total, eight RC column pier specimens were experimentally investigated for their seismic performance and the influence of steel corrosion and axial repeated loading on that performance. It was demonstrated that corrosion had a significant influence on yield strength and ultimate load-bearing capacity of the column piers. Compared with non-corroded specimens, the load-bearing capacity was 18·27% lower when the corrosion of the longitudinal steel bar was 7·16%. Axial repeated loading had no significant influence on mechanical properties of the piers. Finite-element analysis was conducted to assess the effect of different parameters on the seismic performance of the piers, including concrete strength, longitudinal reinforcement ratio, axial compression ratio, height of column and stirrup ratio. As the ratio of axial compression stress to the strength was increased from 0·1 to 0·4, the maximum load-bearing capacity was increased by 27·3% from 55 kN to 70 kN. However, the ultimate displacement was significantly decreased by 42·9% from 35 mm to 20 mm.

1 June 2012 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
YWYi-Lin Wang
Yi-Lin Wang
XLXi-La Liu
Xi-La Liu
CFCongqi Fang
Congqi Fang
This paper investigates new damage detection method for bridges to ensure their safety. The idea of using displacement data of two symmetrical points for multiple damage detection is presented for the first time. After introducing the concept of Equivalent Element, a novel index termed as “Symmetrical Displacement Difference Index (SDDI),” is proposed. The displacement under static load is used for constructing the new index. Then the relationship between the local flexural stiffness change caused by damage and SDDI value is generated. In application, SDDI values can be plotted after the measurement of displacement. The relative changes between the intact state and the damage state in the curve shapes can be used to indicate the position of damage. This new damage detection method based on SDDI is flexible enough to be applied to real-world bridges with inherent random uncertainty and actual support condition. Numerical and experimental examples have been conducted to examine the suitability of the method. This paper provides a simple, convenient, cost-effective, and nondestructive damage detection method for bridges.