Biao Wang

Prof. Biao Wang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in Advanced Science
Verified
Journal Article
Open access
PDF file
WLWeikang Lin
Weikang Lin
Biao WangBiao Wang
Biao Wang
GPGuoxiang Peng
Guoxiang Peng
YSYao Shan
Yao Shan
HHHong Hu
Hong Hu
ZYZhengbao Yang
Zhengbao Yang
Real‐time detection and differentiation of diverse external stimuli with one tactile senor remains a huge challenge and largely restricts the development of electronic skins. Although different sensors have been described based on piezoresistivity, capacitance, and triboelectricity, and these devices are promising for tactile systems, there are few, if any, piezoelectric sensors to be able to distinguish diverse stimuli in real time. Here, a human skin‐inspired piezoelectric tactile sensor array constructed with a multilayer structure and row+column electrodes is reported. Integrated with a signal processor and a logical algorithm, the tactile sensor array achieves to sense and distinguish the magnitude, positions, and modes of diverse external stimuli, including gentle slipping, touching, and bending, in real time. Besides, the unique design overcomes the crosstalk issues existing in other sensors. Pressure sensing and bending sensing tests show that the proposed tactile sensor array possesses the characteristics of high sensitivity (7.7 mV kPa−1), long‐term durability (80 000 cycles), and rapid response time (10 ms) (less than human skin). The tactile sensor array also shows a superior scalability and ease of massive fabrication. Its ability of real‐time detection and differentiation of diverse stimuli for health monitoring, detection of animal movements, and robots is demonstrated.

12 March 2021 in Science Advances
Verified
Journal Article
Open access
PDF file
YHYing Hong
Ying Hong
Biao WangBiao Wang
Biao Wang
WLWeikang Lin
Weikang Lin
LJLihan Jin
Lihan Jin
SLShiyuan Liu
Shiyuan Liu
ZYZhengbao Yang
Zhengbao Yang
The prevention of work-related upper extremity musculoskeletal disorders (MSDs; e.g., neck pain and shoulder fatigue) requires frequent exercises of neck and shoulder that primarily rely on the assistance of joint motion monitoring devices. However, most available wearable healthcare sensors are rigid, bulky, and incapable of recognizing the full range of human motions. Here, we propose a kirigami-structured highly anisotropic piezoelectric network composite sensor that is able to monitor multiple information of joint motions, including bending direction, bending radius, and motion modes, and to distinguish them simultaneously within one sensor unit. On the basis of the modified template-assisted processing method, we design a functional piezoceramic kirigami with a honeycomb network structure that is stretchable (~100% strain), highly sensitive (15.4 mV kPa−1), and highly anisotropic to bending directions (17.3 times from 90° to 0°). An integrated monitoring system is further established to alarm the prolonged sedentary behaviors, facilitating the prevention of upper extremity MSDs.

30 July 2024 in Nonlinear Dynamics
Verified
Journal Article
Closed access
PDF file
XZXiao Zhang
Xiao Zhang
Xingbao HuangXingbao Huang
Xingbao Huang
Biao WangBiao Wang
Biao Wang


4 November 2021 in Energy & Environmental Science
Verified
Journal Article
Closed access
PDF file
YHYing Hong
Ying Hong
LJLihan Jin
Lihan Jin
Biao WangBiao Wang
Biao Wang
JLJunchen LIAO
Junchen LIAO
BHBing He
Bing He
ZYZhengbao Yang
Zhengbao Yang
Bioelectronic devices implanted within the human body are increasingly used for diagnostic and therapeutic purposes, in which their functions and lifespan could be significantly improved with wireless energy transfer technology. However, limited by electromagnetic radiation, low power output, high stiffness, short transfer distance and tissue attenuation, most wireless energy transfer systems cannot meet the requirements of implantable medical devices (IMDs). Here, inspired by natural wood structures, we present a transmuscular ultrasonic wireless power transfer system based on a flexible wood-templated piezoelectric ultrasonic energy harvester (W-PUEH) in a unidirectional 3D interconnected ceramic–polymer topology. The developed flexible W-PUEH device demonstrates an output voltage of 21 V, an output current of 2 mA, and an average output power density of 304 μW cm−2, one order of magnitude higher than the state of the art. Further ex vivo and in vivo experiments demonstrate the sufficient power supply capacity of W-PUEH and its potential applications in implantable devices for the improvement of life quality and well-being of the recipients.

12 July 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
XLXiaowei Li
Xiaowei Li
YZYuan Zhou
Yuan Zhou
ZLZhongjie Li
Zhongjie Li
HGHengyu Guo
Hengyu Guo
YGYing GONG
Ying GONG
YPYan Peng
Yan Peng