Guddi Suman

Dr. Guddi Suman


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2026 in Science
Verified
Journal Article
Closed access
ACAlex J. Commisso
Alex J. Commisso
ENEric M. Nagel
Eric M. Nagel
MKMeghan T. Kiker
Meghan T. Kiker
ERElizabeth A. Recker
Elizabeth A. Recker
ABAdam Bischoff
Adam Bischoff
SLSamuel Leguizamon
Samuel Leguizamon
For semicrystalline polyolefin thermoplastics, the balance between interconnected ordered crystalline and disordered amorphous regions is paramount to their performance and processability. However, contemporary manufacturing strategies, from injection molding to three-dimensional (3D) printing, result in monolithic objects, unable to spatially encode crystallinity. We develop a light-based approach for fabricating mechanically robust polyolefin thermoplastics with microscopic control over crystallinity in 3D space. Light dosage governs polymer stereochemistry giving access to a continuum of materials, from strong rigid plastics, such as high-density polyethylene, to more extensible materials akin to low-density polyethylene, all at the flick of a switch. Leveraging this finding in lithographic grayscale 3D printing enables rapid multimaterial fabrication with voxel-level control over optical and mechanical properties, opening avenues in information storage, soft robotics, and energy damping.

27 September 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GSGuddi Suman
Guddi Suman
MPMerlyn Xavier Pulikkathara
Merlyn Xavier Pulikkathara
RWRichard T Wilkins
Richard T Wilkins
LTLaRico J. Treadwell
LaRico J. Treadwell
This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

1 January 2021 in International Journal of Advances in Scientific Research and Engineering
Verified
Journal Article
Open access
MSMatthew N. O. Sadiku
Matthew N. O. Sadiku
GSGuddi Suman
Guddi Suman
SMSarhan M. Musa
Sarhan M. Musa

16 February 2023 in Inorganics
Verified
Journal Article
Open access
PDF file
RSRyan Schoell
Ryan Schoell
ARAspen Reyes
Aspen Reyes
GSGuddi Suman
Guddi Suman
MLMila Nhu Lam
Mila Nhu Lam
JHJustin Hamil
Justin Hamil
ELEric Lang
Eric Lang
Metal-oxide composites are commonly used in high temperature environments for their thermal stability and high melting points. Commonly employed with refractory oxides or carbides such as ZrC and HfC, these materials may be improved with the use of a low density, high melting point ceramic such as CeO2. In this work, the consolidation of W-CeO2 metal matrix composites in the high CeO2 concentration regime is explored. The CeO2 concentrations of 50, 33, and 25 wt.%, the CeO2 particle size from nanometer to micrometer, and various hot isostatic pressing temperatures are investigated. Decreasing the CeO2 concentration is observed to increase the composite density and increase the Vickers hardness. The CeO2 oxidation state is observed to be a combination of Ce3+ and Ce4+, which is hypothesized to contribute to the porosity of the composites. The hardness of the metal-oxide composite can be improved more than 2.5 times compared to pure W processed by the same route. This work offers processing guidelines for further consolation of oxide-doped W composites.

14 May 2021 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
GSGuddi Suman
Guddi Suman
MPMerlyn Xavier Pulikkathara
Merlyn Xavier Pulikkathara
RWRichard T Wilkins
Richard T Wilkins
This paper studies the response of a radiation sensor that was developed from single-walled carbon nanotube (SWCNT) and poly (methyl methacrylate) (PMMA) nanocomposite thin films placed on an interdigitated electrode (IDE). We studied the effects of X-rays in real-time electrical resistance of the thin film nanocomposites. A 160 kV X-ray source irradiated the nanocomposite devices with ionizing X-ray radiation at different doses and dose rates, causing the decrease in resistance of thin film through the production of charge carriers. The embedded SWCNT network helped transport radiation-induced electrons to the electrodes. Pre-irradiation resistance can be obtained rapidly from heat treatment of irradiated nanocomposite devices. It is observed that the required heat treatment time for thin film device recovery increased almost linearly with applied radiation dose. The thin film devices were operated at dc voltage as low as 0.05 V for reliable measurement of the radiation-induced change in electrical resistance. The results of this study suggest that SWCNT/PMMA thin film devices could be used for sensing X-ray radiation, with significantly higher sensitivity than comparable devices made with multi-walled CNT (MWCNT) based nanocomposites in a previous study.

1 January 2021 in International Journal of Advances in Scientific Research and Engineering
Verified
Journal Article
Open access
MSMatthew N. O. Sadiku
Matthew N. O. Sadiku
GSGuddi Suman
Guddi Suman
SMSarhan M. Musa
Sarhan M. Musa