Giulia Luraghi

Dr. Giulia Luraghi

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2019 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
GLGiulia Luraghi
Giulia Luraghi
FMFrancesco Migliavacca
Francesco Migliavacca
AGAlberto García-González
Alberto García-González
CCClaudio Chiastra
Claudio Chiastra
ARAlexia Rossi
Alexia Rossi
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas

1 June 2017 in Journal of Biomechanics
Verified
Journal Article
Open access
GLGiulia Luraghi
Giulia Luraghi
WWWei Wu
Wei Wu
FGFrancesco De Gaetano
Francesco De Gaetano
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas
GMGeoff D. Moggridge
Geoff D. Moggridge
FMFrancesco Migliavacca
Francesco Migliavacca
Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, like the transcatheter aortic valve implantation. Nevertheless, PHVs are not currently used for clinical applications due to their lack of reliability. In order to investigate the main features of this new class of prostheses, pulsatile tests in an in-house pulse duplicator were carried out and reproduced in silico with both structural Finite-Element (FE) and Fluid-Structure interaction (FSI) analyses. Valve kinematics and geometric orifice area (GOA) were evaluated to compare the in vitro and the in silico tests. Numerical results showed better similarity with experiments for the FSI than for the FE simulations. The maximum difference between experimental and FSI GOA at maximum opening time was only 5%, as compared to the 46.5% between experimental and structural FE GOA. The stress distribution on the valve leaflets clearly reflected the difference in valve kinematics. Higher stress values were found in the FSI simulations with respect to those obtained in the FE simulation. This study demonstrates that FSI simulations are more appropriate than FE simulations to describe the actual behaviour of PHVs as they can replicate the valve-fluid interaction while providing realistic fluid dynamic results.

11 December 2020 in Interface Focus
Verified
Journal Article
Open access
GLGiulia Luraghi
Giulia Luraghi
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas
GDGabriele Dubini
Gabriele Dubini
BFBerti Francesca
Berti Francesca
SBSara Bridio
Sara Bridio
OIon behalf of the INSIST investigators
on behalf of the INSIST investigators
An acute ischaemic stroke appears when a blood clot blocks the blood flow in a cerebral artery. Intra-arterial thrombectomy, a mini-invasive procedure based on stent technology, is a mechanical available treatment to extract the clot and restore the blood circulation. After stent deployment, the clot, trapped in the stent struts, is pulled along with the stent towards a receiving catheter. Recent clinical trials have confirmed the effectiveness and safety of mechanical thrombectomy. However, the procedure requires further investigation. The aim of this study is the development of a numerical finite-element-based model of the thrombectomy procedure. In vitro thrombectomy tests are performed in different vessel geometries and one simulation for each test is carried out to verify the accuracy and reliability of the proposed numerical model. The results of the simulations confirm the efficacy of the model to replicate all the experimental setups. Clot stress and strain fields from the numerical analysis, which vary depending on the geometric features of the vessel, could be used to evaluate the possible fragmentation of the clot during the procedure. The proposed in vitro/in silico comparison aims at assessing the applicability of the numerical model and at providing validation evidence for the specific in vivo thrombectomy outcomes prediction.

14 September 2020 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
GLGiulia Luraghi
Giulia Luraghi
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas
MBMarta Beretta
Marta Beretta
NCNicole Chiozzi
Nicole Chiozzi
LILaura Iannetti
Laura Iannetti
FMFrancesco Migliavacca
Francesco Migliavacca
Transcatheter aortic valve replacement (TAVR) strongly depends on the calcification patterns, which may lead to a malapposition of the stented valve and complication onsets in terms of structure kinematics and paravalvular leakage (PVL). From one anatomical-resembling model of the aortic root, six configurations with different calcific deposits were built. TAVR fluid-structure interaction simulations predicted different outcomes for the different calcifications patterns in terms of the final valve configuration in the implantation site and the PVL estimations. In particular models with deposits along the cups coaptation resulted in mild PVL, while those with deposits along the attachment line in moderate PVL.

21 August 2018 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
GLGiulia Luraghi
Giulia Luraghi
FMFrancesco Migliavacca
Francesco Migliavacca
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas

1 September 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
GLGiulia Luraghi
Giulia Luraghi
SBSara Bridio
Sara Bridio
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas
GDGabriele Dubini
Gabriele Dubini
NBNikki Boodt
Nikki Boodt
FMFrancesco Migliavacca
Francesco Migliavacca