Marina Strocchi

Dr. Marina Strocchi


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MSMarina Strocchi
Marina Strocchi
CAChristoph Michael Augustin
Christoph Michael Augustin
MGMatthias A. F. Gsell
Matthias A. F. Gsell
EKElias Karabelas
Elias Karabelas
ANAurel Neic
Aurel Neic
SNSteven A. Niederer
Steven A. Niederer
Computational models of the heart are increasingly being used in the development of devices, patient diagnosis and therapy guidance. While software techniques have been developed for simulating single hearts, there remain significant challenges in simulating cohorts of virtual hearts from multiple patients. To facilitate the development of new simulation and model analysis techniques by groups without direct access to medical data, image analysis techniques and meshing tools, we have created the first publicly available virtual cohort of twenty-four four-chamber hearts. Our cohort was built from heart failure patients, age 67±14 years. We segmented four-chamber heart geometries from end-diastolic (ED) CT images and generated linear tetrahedral meshes with an average edge length of 1.1±0.2mm. Ventricular fibres were added in the ventricles with a rule-based method with an orientation of -60° and 80° at the epicardium and endocardium, respectively. We additionally refined the meshes to an average edge length of 0.39±0.10mm to show that all given meshes can be resampled to achieve an arbitrary desired resolution. We ran simulations for ventricular electrical activation and free mechanical contraction on all 1.1mm-resolution meshes to ensure that our meshes are suitable for electro-mechanical simulations. Simulations for electrical activation resulted in a total activation time of 149±16ms. Free mechanical contractions gave an average left ventricular (LV) and right ventricular (RV) ejection fraction (EF) of 35±1% and 30±2%, respectively, and a LV and RV stroke volume (SV) of 95±28mL and 65±11mL, respectively. By making the cohort publicly available, we hope to facilitate large cohort computational studies and to promote the development of cardiac computational electro-mechanics for clinical applications.

15 April 2021 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
CRCristobal Rodero
Cristobal Rodero
MSMarina Strocchi
Marina Strocchi
MMMaciej Marciniak
Maciej Marciniak
SLStefano Longobardi
Stefano Longobardi
JWJohn Whitaker
John Whitaker
SNSteven A. Niederer
Steven A. Niederer
Cardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n= 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R= 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function.

1 March 2020 in Journal of Biomechanics
Verified
Journal Article
Open access
MSMarina Strocchi
Marina Strocchi
MGMatthias A.F. Gsell
Matthias A.F. Gsell
CAChristoph Michael Augustin
Christoph Michael Augustin
OROrod Razeghi
Orod Razeghi
CRCaroline H. Roney
Caroline H. Roney
SNSteven A. Niederer
Steven A. Niederer
The pericardium affects cardiac motion by limiting epicardial displacement normal to the surface. In computational studies, it is important for the model to replicate realistic motion, as this affects the physiological fidelity of the model. Previous computational studies showed that accounting for the effect of the pericardium allows for a more realistic motion simulation. In this study, we describe the mechanism through which the pericardium causes improved cardiac motion. We simulated electrical activation and contraction of the ventricles on a four-chamber heart in the presence and absence of the effect of the pericardium. We simulated the mechanical constraints imposed by the pericardium by applying normal Robin boundary conditions on the ventricular epicardium. We defined a regional scaling of normal springs stiffness based on image-derived motion from CT images. The presence of the pericardium reduced the error between simulated and image-derived end-systolic configurations from 12.8±4.1 mm to 5.7±2.5 mm. First, the pericardium prevents the ventricles from spherising during isovolumic contraction, reducing the outward motion of the free walls normal to the surface and the upwards motion of the apex. Second, by restricting the inward motion of the free and apical walls of the ventricles the pericardium increases atrioventricular plane displacement by four folds during ejection. Our results provide a mechanistic explanation of the importance of the pericardium in physiological simulations of electromechanical cardiac function.

26 June 2023 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
MSMarina Strocchi
Marina Strocchi
SLStefano Longobardi
Stefano Longobardi
CAChristoph Michael Augustin
Christoph Michael Augustin
MGMatthias A. F. Gsell
Matthias A. F. Gsell
APArgyrios Petras
Argyrios Petras
SNSteven A. Niederer
Steven A. Niederer
Cardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes.

1 November 2020 in Heart Rhythm
Verified
Journal Article
Open access
MSMarina Strocchi
Marina Strocchi
ALAngela W.C. Lee
Angela W.C. Lee
ANAurel Neic
Aurel Neic
JBJulien Bouyssier
Julien Bouyssier
KGKarli Gillette
Karli Gillette
SNSteven A. Niederer
Steven A. Niederer
His-bundle pacing (HBP) and left bundle pacing (LBP) are emerging as novel delivery methods for cardiac resynchronization therapy (CRT) in heart failure patients with left bundle branch block (LBBB). HBP and LBP have never been compared to biventricular endocardial (BiV-endo) pacing. Furthermore, there are indications of negative effects of LBP on right ventricular (RV) activation times (ATs), but these effects have not been quantified. The purpose of this study was to compare changes in ventricular activation induced by HBP, LBP, left ventricular (LV) septal pacing, BiV-endo, and biventricular epicardial (BiV-epi) pacing using computer simulations. We simulated ventricular activation on 24 four-chamber heart meshes inclusive of the His-Purkinje network in the presence of LBBB. We simulated BiV-epi pacing, BiV-endo pacing with left ventricular (LV) lead at the lateral wall, BiV-endo pacing with LV lead at the LV septum, HBP, and LBP. HBP was superior to BiV-endo and BiV-epi in terms of reduction in LV ATs and interventricular dyssynchrony (P <.05). LBP reduced LV ATs but not interventricular dyssynchrony compared to BiV-epi and BiV-endo pacing. RV latest AT was higher with LBP than with HBP (141.3 ± 10.0 ms vs 111.8 ± 10.4 ms). Optimizing AV delay during LBP reduced RV latest AT (104.7 ± 8.7 ms) and led to comparable response to HBP. In case of complete AV block, BiV-endo septal pacing was equivalent to LBP. HBP is superior to BiV-epi and BiV-endo. To achieve comparable response to HBP, AV delay optimization during LBP is required in order to reduce RV ATs.

3 December 2024 in EP Europace
Verified
Journal Article
Open access
PBPranav Bhagirath
Pranav Bhagirath
MSMarina Strocchi
Marina Strocchi
MBMartin Bishop
Martin Bishop
PBPatrick M Boyle
Patrick M Boyle
GPGernot Plank
Gernot Plank
This State of the Future Review describes and discusses the potential transformative power of digital twins in cardiac electrophysiology. In this ‘big picture’ approach, we explore the evolution of mechanistic modelling based digital twins, their current and immediate clinical applications, and envision a future where continuous updates, advanced calibration, and seamless data integration redefine clinical practice of cardiac electrophysiology. Our aim is to inspire researchers and clinicians to embrace the extraordinary possibilities that digital twins offer in the pursuit of precision medicine.