Purpose: To investigate the relationship between the corneal material stiffness parameter stress-strain index (SSI) and axial length (AL) elongation with varying severities of myopia, based on a mathematical estimation model.Methods: This single-center, cross-sectional study included data from healthy subjects and patients preparing for refractive surgery in the Qingdao Eye Hospital of Shandong First Medical University. Data were collected from July 2021 to April 2022. First, we performed and tested an estimated AL model () based on the mathematical equation proposed by Morgan. Second, we proposed an axial increment model () corresponding to spherical equivalent error (SER) based on ( at SER = 0) and subject’s real AL. Finally, we evaluated the variations of with SSI changes based on the mathematical estimation model.Results: We found that AL was closely associated with (r = 0.91, t = 33.8, p < 0.001) with good consistency and SER was negatively associated with (r = −0.89, t = −30.7, p < 0.001). The association of SSI with AL, , and can be summarized using the following equations: , , and . In adjusted models, SSI was negatively associated with AL (Model 1: β = −2.01, p < 0.001) and (Model 3: β = −2.49, p < 0.001) but positively associated with (Model 2: β = 0.48, p < 0.05). In addition, SSI was negatively associated with among subjects with AL ≥ 26 mm (β = −1.36, p = 0.02).Conclusion: AL increased with decreasing SSI in myopia.
18 October 2023 in Frontiers in Bioengineering and Biotechnology
The stress–strain index (SSI) is a measure of corneal material stiffness, which is obtained using the Corvis ST algorithm based on dynamic corneal response parameters. The reduced SSI corresponds to the longer axial length (AL). In a previous study, we found SSI increases as the corneal curvature flattens, whereas a flatter corneal curvature indicates a longer AL (emmetropia or myopia). Therefore, in this cross-sectional study, we aimed to address these contradictory findings. First, we characterized the features of SSI, curvature radius of the anterior corneal surface (CR), and AL and analyzed their correlation with advanced myopia. Next, we compared the relationship between AL and SSI after adjusting for the effect of CR. We found a significant positive correlation between SSI and CR, which contradicts the developmental law of axial myopia. Furthermore, after accounting for the effect of CR, we observed a stronger correlation between SSI and AL than that in the unadjusted model. In conclusion, CR is an independent influencing factor for SSI in addition to AL, which masked the decrease in SSI caused by prolonged AL in axial myopia.
Accurate assessment of anterior segment parameters is essential for clinical decision-making and ophthalmic research. With the increasing availability of domestically developed anterior segment imaging systems, independent evaluation of their measurement characteristics relative to established devices is required. This study aimed to compare anterior segment measurements obtained using Scansys TA517, a domestically developed Scheimpflug-based imaging system, with those from Pentacam HR. A total of 214 eyes were examined using both devices during the same visit. Anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), white-to-white corneal diameter (WTW), pupil diameter (PD), and the ACD/WTW ratio were analyzed. Inter-device differences were evaluated using Bland–Altman analysis, and proportional bias was assessed by linear regression of inter-device differences against the mean of the two measurements. Inter-device differences varied substantially across parameters. ACD and the ACD/WTW ratio demonstrated minimal mean bias, narrow limits of agreement, and no proportional bias, indicating high inter-device stability and reliability. In contrast, ACA and ACV exhibited larger bias, wider limits of agreement, and significant proportional bias. WTW and PD showed intermediate stability with evidence of magnitude-dependent discrepancies. In conclusion, inter-device agreement between Scansys TA517 and Pentacam HR is parameter-dependent. Linear and ratio-based parameters demonstrated greater stability than angle- and volume-based measurements, and proportional bias was present for several parameters. These findings highlight the importance of parameter-specific and device-specific interpretation when comparing anterior segment measurements across imaging systems.