Qi Ren

Dr. Qi Ren

Ophthalmology, Shandong Eye Institute & Hospital, Qingdao, Shandong, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
ZCZhe Chu
Zhe Chu
Qi RenQi Ren
Qi Ren
MCMeizhen Chen
Meizhen Chen
LCLu Cheng
Lu Cheng
HCHao Cheng
Hao Cheng
JWJie Wu
Jie Wu
Purpose: This study aimed to investigate the correlation of axial length/corneal radius of curvature ratio with stress–strain index (SSI).Methods: Retrospective analysis was conducted to compare the right eyes of those with high myopia (HM, n = 132; age and 10–48 years) with those without high myopia (NHM, n = 135; age and 7–48 years), where the baseline axial length, corneal radius of curvature ratio, and central corneal thickness were analyzed; the differences in two groups were compared; and the relationship of axial length and axial length/corneal radius of curvature ratio with SSI were explored.Results: Compared with AL < 26mm, SSI significantly decreased when AL ≥ 26 mm (p = 0.001), while there was no correlation with AL in the NHM group (r = -0.14, p = 0.12) or HM group (r = -0.09, p = 0.32). AL/CR was significantly associated with SSI in both the NHM (r = -0.4, p < 0.001) and HM (r = -0.18, p = 0.04) groups. In the NHM group, AL/CR was significantly associated with SSI (unstandardized beta = -0.514, se = 0.109, p < 0.001) with the adjustment of age and gender. Additionally, a significant association of SSI with AL/CR was also found after adjusting for age and gender (unstandardized beta = -0.258, se = 0.096, and p = 0.0082) in the HM group.Conclusion: SSI showed a significant negative correlation with AL/CR in patients without high myopia and in patients with high myopia. However, SSI exhibited no decrease with the worsening of myopia, but it gradually remained stable at a low level. The findings of this study validate, to some extent, the possibility of analyzing the dynamic changes in ocular wall stiffness during the development of myopia by measuring in vivo corneal biomechanical parameters.

10 April 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
Qi RenQi Ren
Qi Ren
ZCZhe Chu
Zhe Chu
WCWei Cui
Wei Cui
LCLu Cheng
Lu Cheng
WSWenjie Su
Wenjie Su
JWJie Wu
Jie Wu
Purpose: To investigate the relationship between the corneal material stiffness parameter stress-strain index (SSI) and axial length (AL) elongation with varying severities of myopia, based on a mathematical estimation model.Methods: This single-center, cross-sectional study included data from healthy subjects and patients preparing for refractive surgery in the Qingdao Eye Hospital of Shandong First Medical University. Data were collected from July 2021 to April 2022. First, we performed and tested an estimated AL model (ALMorgan) based on the mathematical equation proposed by Morgan. Second, we proposed an axial increment model (ΔAL) corresponding to spherical equivalent error (SER) based on ALemmetropia (ALMorgan at SER = 0) and subject’s real AL. Finally, we evaluated the variations of ΔAL with SSI changes based on the mathematical estimation model.Results: We found that AL was closely associated with ALMorgan (r = 0.91, t = 33.8, p < 0.001) with good consistency and SER was negatively associated with ΔAL (r = −0.89, t = −30.7, p < 0.001). The association of SSI with AL, ALemmetropia, and ΔAL can be summarized using the following equations: AL=27.7−2.04×SSI, ALemmetropia=23.2+0.561×SSI, and ΔAL=4.52−2.6×SSI. In adjusted models, SSI was negatively associated with AL (Model 1: β = −2.01, p < 0.001) and ΔAL (Model 3: β = −2.49, p < 0.001) but positively associated with ALemmetropia (Model 2: β = 0.48, p < 0.05). In addition, SSI was negatively associated with ΔAL among subjects with AL ≥ 26 mm (β = −1.36, p = 0.02).Conclusion: AL increased with decreasing SSI in myopia.

1 September 2023 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
WCWei Cui
Wei Cui
XWXiaoming Wu
Xiaoming Wu
Qi RenQi Ren
Qi Ren
KLKun Liu
Kun Liu
FKFanqin Kong
Fanqin Kong
JWJie Wu
Jie Wu
Background: To investigate the parameters influencing vault after posterior chamber intraocular lens implantation, thereby establishing a formula to predict the vault after operation. Methods: In this retrospective study, 61 patients (122 eyes) who underwent implantable collamer lens (ICL) implantation were enrolled consecutively from the Qingdao Eye Hospital of Shandong First Medical University, China, between August 2020 and October 2021. Comprehensive optometry, axial length, curvature, anterior chamber depth (ACD), lens thickness (LT), white-to-white distance (WTW), corneal thickness, sulcus-to-sulcus distance (STS), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL), ciliary-to-ciliary distance (CTC) and the distance between the ciliary-to-ciliary plane and the anterior crystalline lens surface (CTCL) were recorded preoperatively. The vault was measured by ultrasound biomicroscopy at 1 month after operation. The correlation among vault, preoperative parameters and ICL size was analyzed. The accuracy and reliability of the prediction formula were verified by analyzing the postoperative correlation coefficient of actual and predicted vaults of the contralateral eye and through the Bland-Altman consistency test. Results: Parameters significantly influencing the vault at 1 month after operation are ACD (r=0.260, P=0.004), LT (r=−0.338, P<0.001), WTW (r=0.240, P=0.03), STSL (r=−0.394, P<0.001), CTC (r=−0.199, P=0.03), CTCL (r=−0.328, P<0.001), ICL size (r=0.224, P=0.01) and ICL power (r=−0.231, P=0.01). The regression formula was as follows: vault (mm) = −2.179 − 0.227 * CTC (vertical) − 0.783 * CTCL (mean) + 0.472 * ICL size (fitting R=0.853, R2=0.727, adjusted R2=0.705). The predicted vault was 0.50±0.18 mm, and the actual vault was 0.56±0.24 mm. The Bland-Altman scatter plot showed a satisfactory agreement between actual and predicted vaults (−0.06 mm, 95% limits of agreement: −0.45 to 0.32 mm). Conclusions: ACD, LT, WTW, STSL, CTC, CTCL, ICL size and ICL power were the factors affecting vault after ICL implantation. The prediction formula with the new parameter CTCL was accurate and reliable.

1 August 2023 in Retina
Verified
Journal Article
Closed access
XMXiubin Ma
Xiubin Ma
QLQianqian Liang
Qianqian Liang
SXShuyue Xue
Shuyue Xue
Qi RenQi Ren
Qi Ren
QDQing Du
Qing Du
JLJun Li
Jun Li
Purpose: To determine the effect of different durations of topical anesthesia on intravitreal injection (IVI) pain. Methods: This was a double-blinded, randomized, comparative study. Three hundred and twelve sequential eyes undergoing IVI were randomized to one of six groups according to the duration of topical anesthesia (from 1 to 30 minutes, one group for every 5-minute range, Groups 1–6). Topical anesthesia before IVI was standardized. Patients graded their pain using the visual analog scale and the Wong–Baker FACES scale at 15 minutes after the procedure. Results: The pain scores among the six groups were significantly different for the visual analog scale (P = 0.013) and Wong–Baker FACES scale (P = 0.024). The mean pain scores for Group 4 were 1.97 ± 1.04 (visual analog scale) and 2.02 ± 1.08 (Wong–Baker FACES scale) and were significantly lower than those of Group 1, 2, 5, or 6. Conclusion: The duration of topical anesthesia significantly correlated with IVI pain. Preoperative 0.5% proparacaine hydrochloride drops were most effective in relieving IVI pain 11 to 20 minutes after topical administration.

16 September 2024 in Research Square
Verified
Preprint
Open access
PDF file
Qi RenQi Ren
Qi Ren
CZChu Zhe
Chu Zhe
HCHao Cheng
Hao Cheng
In this single center retrospective study, we aimed to observe the characteristics of resting potentials between RPE and photoreceptors in RMD patients, based on electrooculography. Seven patients with diffuse RMD diagnosed using infrared fundus photography and optical coherence tomography (OCT) were consecutively reviewed. All 7 patients (14 eyes) underwent routine ophthalmic examinations and were examined by OCT and Electrooculography (EOG). The EOG recordings of the 14 eyes revealed that dark adaptation took 7.21 ± 1.75 minutes to achieve dark trough, whereas light adaptation took 15.79 ± 2.70 minutes from light rise to the light peak. Furthermore, the amplitude of dark trough potential was 262.0–962.1 µV, whereas that of light peak potential was between 373.8 µV and 1.8 mV. In addition, the LP:DT ratio of the 14 eyes observed in this preliminary study was 1.63 ± 0.22, ranged between 1.18 and 1.97, which was lower than 2.35, but was not significantly lower than the lower limit of 1.7 (t = -1.12, P = 0.28). In conclusion, Some EOG parameters of RMD patients are different from normal reference ranges, bioelectric activity between RPE and photoreceptors in patients with RMD may be affected by SDD or RPE abnormalities.