Ayhan Bozkurt

Dr. Ayhan Bozkurt

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
OFOmid Farhanieh
Omid Farhanieh
ASAli Sahafi
Ali Sahafi
RRRupak Bardhan Roy
Rupak Bardhan Roy
AEArif Sanli Ergun
Arif Sanli Ergun
ABAyhan Bozkurt
Ayhan Bozkurt
Conventional High Intensity Focused Ultrasound (HIFU) is a therapeutic modality which is extracorporeally administered. In applications where a relatively small HIFU lesion is required, an intravascular HIFU probe can be deployed to the ablation site. In this paper, we demonstrate the design and implementation a fully integrated HIFU drive system on a chip to be placed on a 6 Fr catheter probe. An 8-element capacitive micromachined ultrasound transducer (CMUT) ring array of 2 mm diameter has been used as the ultrasound source. The driver chip is fabricated in 0.35 μm AMS high-voltage CMOS technology and comprises eight continuous-wave (CW) high-voltage CMUT drivers (10.9 ns and 9.4 ns rise and fall times at 20 V pp output into a 15 pF), an eight-channel digital beamformer (8-12 MHz output frequency with 11.25° phase accuracy) and a phase locked loop with an integrated VCO as a tunable clock source (128-192 MHz). The chip occupies 1.85 × 1.8 mm 2 area including input and output (I/O) pads. When the transducer array is immersed in sunflower oil and driven by the IC with eight 20 V pp CW pulses at 10 MHz, real-time thermal images of the HIFU beam indicate that the focal temperature rises by 16.8 °C in 11 seconds. Each HV driver consumes around 67 mW of power when driving the CMUT array at 10 MHz, which adds up to 560 mW for the whole chip. FEM based analysis reveals that the outer surface temperature of the catheter is expected to remain below the 42 °C tissue damage limit during therapy.

1 August 2018 in Ultrasonics
Verified
Journal Article
Closed access
BUBurcin Ustbas
Burcin Ustbas
DKDeniz Kilic
Deniz Kilic
ABAyhan Bozkurt
Ayhan Bozkurt
MAMustafa Erkin Aribal
Mustafa Erkin Aribal
OAOzge Akbulut
Ozge Akbulut

12 May 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
SASenem Avaz
Senem Avaz
RRR. B. Roy
R. B. Roy
VMV. R. S. S. Mokkapati
V. R. S. S. Mokkapati
ABAyhan Bozkurt
Ayhan Bozkurt
SPSantosh Pandit
Santosh Pandit
YMYusuf Menceloglu
Yusuf Menceloglu
A graphene-based nanosensor was fabricated to selectively detect nitrotriazolone (NTO) molecules with a molecularly imprinted film via simple electrical measurements. Molecularly imprinted polymer comprising chitosan was used as sensitive layer. Gold electrodes for electrical measurements were lithographically fabricated on Si/SiO2 substrate, followed by monolayer graphene transfer and polymeric film coating. Monolayer graphene and molecularly imprinted polymer were characterized by ATR-FTIR, UV-Vis, SEM and Raman spectroscopy. Transfer-length measurements (TLM) indicate that the sensor selectively and linearly responds against aqueous NTO solutions within a wide range of concentration of 0.01–0.1 mg mL−1 that covers the lowest toxic level of NTO determined by USEPA. This nanosensor with embedded electrodes is re-usable and suitable for field applications, offering real-time electrical measurements unlike current techniques where complex analytics are required.

19 September 2008 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ABAyhan Bozkurt
Ayhan Bozkurt
The radiation impedance of a piston transducer mounted in a rigid baffle has been widely addressed in the literature. The real and imaginary parts of the impedance are described by the first order Bessel and Struve functions, respectively. Although there are power series expansions for both functions, the analytic formulation of a lumped circuit is not trivial. In this paper, we present an empirical approach to the derivation of a lumped-circuit model for the radiation impedance expression, based on observations on the near-field behavior of stored kinetic and elastic energy. The field analysis is carried out using a finite element method model of the piston and surrounding fluid medium. We show that fluctuations in the real and imaginary components of the impedance can be modeled by series and shunt tank circuits, each of which shape a certain section of the impedance curve. Because the model is composed of lumped-circuit elements, it can be used in circuit simulators. Consequently, the proposed model is useful for the analysis of transducer front-end circuits.

22 November 2022 in Molecular Neurobiology
Verified
Journal Article
Closed access
PDF file
EDErdem Deveci
Erdem Deveci
FAFahri Akbaş
Fahri Akbaş
AEArif Şanlı Ergun
Arif Şanlı Ergun
AKAyse Kurtulmus
Ayse Kurtulmus
AKAli Barlas Koçak
Ali Barlas Koçak
IKIsmet Kırpınar
Ismet Kırpınar

9 July 2019 in Psychiatry and Clinical Psychopharmacology
Verified
Journal Article
Open access
EDErdem Deveci
Erdem Deveci
AKAlperen Kılıç
Alperen Kılıç
OYOnur Yılmaz
Onur Yılmaz
ANAynur Nabi
Aynur Nabi
AEArif Sanlı Ergün
Arif Sanlı Ergün
IKİsMet Kırpınar
İsMet Kırpınar
Background: Deep Brain Stimulation (DBS) is the only modality proven to be effective on selective stimulation of the deep brain structures. It was previously reported that, by using DBS, stimulation of nucleus accumbens (NA), a region that plays a pivotal role in the pathogenesis of substance addiction, is effective for the treatment of substance addiction. Objective: The purpose of the current study was to observe how the morphine-conditioned place preference changed in rats by stimulating NA with a non-invasive method, focused ultrasound (US) and to detect whether there would be any tissue damage caused by US waves. Methods: We used low-intensity focused ultrasound (LIFU), a noninvasive modality, in a place conditioning model to stimulate NA in rats. Results: At the initial stage of our study, we used morphine to induce place preference. As expected, morphine administration caused significant place preference. After the place preference was obtained by morphine, we divided the rats into two groups. One group received LIFU waves to NA and the other group received only sham, that is, no stimulation with US waves. Rats in both groups were continued to receive morphine. Then, we investigated whether LIFU and sham will reduce morphine-induced place preference or not. We observed that morphine-induced place preference had an ongoing raise in the sham group while no raise was detected in the ultrasound group. Although LIFU prevented the rats from the raise, it did not cause a significant reduction of morphine preference. Conclusion: We state that there is a need for future studies to investigate the effects of low-intensity focused ultrasound as an alternative treatment modality in addiction.