Star sensors undergo laboratory calibration before they leave the factory. In addition, recalibration is necessary after they experience vibration, deformation, etc. Using the analysis of attitude-dependent and attitude-independent interstar angular invariance calibration methods (IAICMs) as a reference, an attitude-correlated frame-based calibration method (ACFCM) is proposed in this work, which combines the advantages of both methods. Using outdoor star observations, the ACFCM correlates star image frames obtained at different times via a strapdown gyro unit. As a result, the number of efficient star images for calibration increases rapidly and the distribution of star images becomes much more uniform, thus improving the calibration accuracy of the star sensor. A simulation and experimental tests were designed and carried out. Both the simulation and experimental results verify the feasibility of the proposed ACFCM method. Furthermore, by comparing our method with the IAICMs, the repeatability and reliability of the principal point obtained from the calibration with the ACFCM method proposed in this work were significantly improved.
The pump heating effect of DFB fiber laser is normally ignored due to the short length of the laser cavity. However, by fabricating a phase-shifted FBG on high concentration Er-Yb codoped fiber to obtain a 16 mm long DFB fiber laser, the gradient surface temperature distributions along the active grating with different pump powers were observed. The average surface temperature rose by 16.82 K with a variation of less than 1.11 K, and the position with the highest temperature moved towards the center of the grating by 5.5 mm, when the pump power was increased from 0 mW to 191.6 mW. The transmission spectrum of the active phase-shifted FBG at different pump powers were measured, and an additional drift of the transmission peak in the stopband was testified. It was identified as an equivalent phase shift up to −0.1 π, which was induced by the gradient longitudinal temperature distribution. Considering that the initial phase shift of the grating was about 1.15 π, the increasing chirp of the active grating due to the pump heating could compensate the phase shift deviation from π surprisingly. The experimental results coincided with the simulation results by using the transmission matrix method under the assumption of piecewise-uniform structure for the chirped phase-shifted grating. The modified model of the active phase-shifted FBG reveals the difference between the cool cavity and the hot cavity at different pump powers, which may be used as a self-optimization mechanism for DFB fiber laser operation.
A diode-end-pumped self-mode-locked Tm,Ho:LuLiF4 (LLF) laser is demonstrated for the first time, to the best of our knowledge. At the incident pump power of 3.4 W, the stable self-mode-locked operation of the Tm,Ho:LLF laser was realized without any additional devices in the resonator. Further increasing the incident pump power to 6.8 W, the maximum average output power of 1.07 W was achieved at 2068 nm with a pulse width of 746 ps and a repetition frequency of 468 MHz. The experimental results indicate that the Tm,Ho:LLF crystal is promising to generate the high-power self-mode-locked solid-state laser at 2 μm waveband. The self-mode-locked Tm,Ho:LLF laser has potential applications in optical communication, remote sensing, material process, and nonlinear frequency conversion.