Adrian Pranata

Dr. Adrian Pranata

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TPTrung Phan
Trung Phan
APAdrian Pranata
Adrian Pranata
JFJoshua Farragher
Joshua Farragher
Adam Leigh BryantAdam Leigh Bryant
Adam Leigh Bryant
HNHung Nguyen
Hung Nguyen
Rifai ChaiRifai Chai
Rifai Chai
This paper proposes an innovative methodology for finding how many lifting techniques people with chronic low back pain (CLBP) can demonstrate with camera data collected from 115 participants. The system employs a feature extraction algorithm to calculate the knee, trunk and hip range of motion in the sagittal plane, Ward’s method, a combination of K-means and Ensemble clustering method for classification algorithm, and Bayesian neural network to validate the result of Ward’s method and the combination of K-means and Ensemble clustering method. The classification results and effect size show that Ward clustering is the optimal method where precision and recall percentages of all clusters are above 90, and the overall accuracy of the Bayesian Neural Network is 97.9%. The statistical analysis reported a significant difference in the range of motion of the knee, hip and trunk between each cluster, F (9, 1136) = 195.67, p < 0.0001. The results of this study suggest that there are four different lifting techniques in people with CLBP. Additionally, the results show that even though the clusters demonstrated similar pain levels, one of the clusters, which uses the least amount of trunk and the most knee movement, demonstrates the lowest pain self-efficacy.

25 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CMCharlotte Marshall
Charlotte Marshall
DEDoa El-Ansary
Doa El-Ansary
APAdrian Pranata
Adrian Pranata
CGCharlotte Ganderton
Charlotte Ganderton
JOJohn M O’Donnell
John M O’Donnell
Oren TiroshOren Tirosh
Oren Tirosh
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory’s 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63–0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85–0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36–0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87–0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.

19 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TPTrung Phan
Trung Phan
APAdrian Pranata
Adrian Pranata
JFJoshua Farragher
Joshua Farragher
Adam Leigh BryantAdam Leigh Bryant
Adam Leigh Bryant
HNHung Nguyen
Hung Nguyen
Rifai ChaiRifai Chai
Rifai Chai
Machine learning (ML) algorithms are crucial within the realm of healthcare applications. However, a comprehensive assessment of the effectiveness of regression algorithms in predicting alterations in lifting movement patterns has not been conducted. This research represents a pilot investigation using regression-based machine learning techniques to forecast alterations in trunk, hip, and knee movements subsequent to a 12-week strength training for people who have low back pain (LBP). The system uses a feature extraction algorithm to calculate the range of motion in the sagittal plane for the knee, trunk, and hip and 12 different regression machine learning algorithms. The results show that Ensemble Tree with LSBoost demonstrated the utmost accuracy in prognosticating trunk movement. Meanwhile, the Ensemble Tree approach, specifically LSBoost, exhibited the highest predictive precision for hip movement. The Gaussian regression with the kernel chosen as exponential returned the highest prediction accuracy for knee movement. These regression models hold the potential to significantly enhance the precision of visualisation of the treatment output for individuals afflicted with LBP.

26 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CMCharlotte Marshall
Charlotte Marshall
CGCharlotte Ganderton
Charlotte Ganderton
AFAdam Feltham
Adam Feltham
DEDoa El-Ansary
Doa El-Ansary
APAdrian Pranata
Adrian Pranata
Oren TiroshOren Tirosh
Oren Tirosh
Background: The COVID-19 pandemic has accelerated the demand for utilising telehealth as a major mode of healthcare delivery, with increasing interest in the use of tele-platforms for remote patient assessment. In this context, the use of smartphone technology to measure squat performance in people with and without femoroacetabular impingement (FAI) syndrome has not been reported yet. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their squat performance in real time using the smartphone inertial sensors. The aim of this study was to investigate the association and test–retest reliability of the TelePhysio app in measuring postural sway performance during a double-leg (DLS) and single-leg (SLS) squat task. In addition, the study investigated the ability of TelePhysio to detect differences in DLS and SLS performance between people with FAI and without hip pain. Methods: A total of 30 healthy (nfemales = 12) young adults and 10 adults (nfemales = 2) with diagnosed FAI syndrome participated in the study. Healthy participants performed DLS and SLS on force plates in our laboratory, and remotely in their homes using the TelePhysio smartphone application. Sway measurements were compared using the centre of pressure (CoP) and smartphone inertial sensor data. A total of 10 participants with FAI (nfemales = 2) performed the squat assessments remotely. Four sway measurements in each axis (x, y, and z) were computed from the TelePhysio inertial sensors: (1) average acceleration magnitude from the mean (aam), (2) root-mean-square acceleration (rms), (3) range acceleration (r), and (4) approximate entropy (apen), with lower values indicating that the movement is more regular, repetitive, and predictable. Differences in TelePhysio squat sway data were compared between DLS and SLS, and between healthy and FAI adults, using analysis of variance with significance set at 0.05. Results: The TelePhysio aam measurements on the x- and y-axes had significant large correlations with the CoP measurements (r = 0.56 and r = 0.71, respectively). The TelePhysio aam measurements demonstrated moderate to substantial between-session reliability values of 0.73 (95% CI 0.62–0.81), 0.85 (95% CI 0.79–0.91), and 0.73 (95% CI 0.62–0.82) for aamx, aamy, and aamz, respectively. The DLS of the FAI participants showed significantly lower aam and apen values in the medio-lateral direction compared to the healthy DLS, healthy SLS, and FAI SLS groups (aam = 0.13, 0.19, 0.29, and 0.29, respectively; and apen = 0.33, 0.45, 0.52, and 0.48, respectively). In the anterior–posterior direction, healthy DLS showed significantly greater aam values compared to the healthy SLS, FAI DLS, and FAI SLS groups (1.26, 0.61, 0.68, and 0.35, respectively). Conclusions: The TelePhysio app is a valid and reliable method of measuring postural control during DLS and SLS tasks. The application is capable of distinguishing performance levels between DLS and SLS tasks, and between healthy and FAI young adults. The DLS task is sufficient to distinguish the level of performance between healthy and FAI adults. This study validates the use of smartphone technology as a tele-assessment clinical tool for remote squat assessment.

25 November 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
MRMariadas Capsran Roshan
Mariadas Capsran Roshan
MIMats Isaksson
Mats Isaksson
APAdrian Pranata
Adrian Pranata
EHEdgar M. Hidalgo
Edgar M. Hidalgo

31 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
APAdrian Pranata
Adrian Pranata
JFJoshua Farragher
Joshua Farragher
LPLuke Perraton
Luke Perraton
DEDoa El-Ansary
Doa El-Ansary
RCRoss Clark
Ross Clark
Adam Leigh BryantAdam Leigh Bryant
Adam Leigh Bryant
The ability of the lumbar extensor muscles to accurately control static and dynamic forces is important during daily activities such as lifting. Lumbar extensor force control is impaired in low-back pain patients and may therefore explain the variances in lifting kinematics. Thirty-three chronic low-back pain participants were instructed to lift weight using a self-selected technique. Participants also performed an isometric lumbar extension task where they increased and decreased their lumbar extensor force output to match a variable target force within 20–50% lumbar extensor maximal voluntary contraction. Lifting trunk and lower limb range of motion and angular velocity variables derived from phase plane analysis in all planes were calculated. Lumbar extensor force control was analyzed by calculating the Root-Mean-Square Error (RMSE) between the participants’ force and the target force during the increasing (RMSEA), decreasing (RMSED) force portions and for the overall force error (RMSET) of the test. The relationship between lifting kinematics and RMSE variables was analyzed using multiple linear regression. Knee angular velocity in the sagittal and coronal planes were positively associated with RMSEA (R2 = 0.10, β = 0.35, p = 0.046 and R2 = 0.21, β = 0.48, p = 0.004, respectively). Impaired lumbar extensor force control is associated with increased multiplanar knee movement velocity during lifting. The study findings suggest a potential relationship between lumbar and lower limb neuromuscular function in people with chronic low-back pain.