We conducted a systematic review of the literature for assessing the value of home monitoring for heart failure (HF) patients. The abstracts of 383 articles were read. We excluded those in which either no home monitoring was done or only the technical aspects of the telemedicine application were described. Forty-two studies met the selection criteria. We classified the results into feasibility (technical and institutional) and impact (on the clinical process, on patient health, on accessibility and acceptability of the health system, and on the economy). Evaluating the articles showed that home monitoring in HF patients is viable, given that: (1) it appears to be technically effective for following the patient remotely; (2) it appears to be easy to use, and it is widely accepted by patients and health professionals; and (3) it appears to be economically viable. Furthermore, home monitoring of HF patients has been shown to have a positive impact on: (1) the clinical process, supported by a significant improvement of patient follow-up by adjustment of treatment, diet or behaviour, as well as hospital readmissions and emergency visits reduction; (2) the patient's health, supported by a relevant improvement in quality of life, a reduction of days in hospital, and a decrease in mortality; and (3) costs resulting from the use of health resources.
13 February 2009 in IEEE Transactions on Mobile Computing
Indoor location (IL) using received signal strength (RSS) is receiving much attention, mainly due to its ease of use in deployed IEEE 802.11b (Wi-Fi) wireless networks. Fingerprinting is the most widely used technique. It consists of estimating position by comparison of a set of RSS measurements, made by the mobile device, with a database of RSS measurements whose locations are known. However, the most convenient data structure to be used and the actual performance of the proposed fingerprinting algorithms are still controversial. In addition, the statistical distribution of indoor RSS is not easy to characterize. Therefore, we propose here the use of nonparametric statistical procedures for diagnosis of the fingerprinting model, specifically: 1) A nonparametric statistical test, based on paired bootstrap resampling, for comparison of different fingerprinting models and 2) new accuracy measurements (the uncertainty area and its bias) which take into account the complex nature of the fingerprinting output. The bootstrap comparison test and the accuracy measurements are used for RSS-IL in our Wi-Fi network, showing relevant information relating to the different fingerprinting schemes that can be used.
Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported, showing the statistical and temporal correspondences and properties with respect to EER signals used to create the gold standard for clinical noise. The proposed noise maps, together with the statistical consistency of the characterization of the noise clinical severity, paves the way towards forthcoming systems providing us with noise maps of the noise clinical severity, allowing the user to process different ECG segments with different techniques and in terms of different measured clinical parameters.
10 May 2010 in IEEE Transactions on Biomedical Engineering
Dominant frequency analysis (DFA) and organization analysis (OA) of cardiac electrograms (EGMs) aims to establish clinical targets for cardiac arrhythmia ablation. However, these previous spectral descriptions of the EGM have often discarded relevant information in the spectrum, such as the harmonic structure or the spectral envelope. We propose a fully automated algorithm for estimating the spectral features in EGM recordings This approach, called Fourier OA (FOA), accounts jointly for the organization and periodicity in the EGM, in terms of the fundamental frequency instead of dominant frequency. In order to compare the performance of FOA and DFA-OA approaches, we analyzed simulated EGM, obtained in a computer model, as well as two databases of implantable defibrillator-stored EGM. FOA parameters improved the organization measurements with respect to OA, and averaged cycle length and regularity indexes were more accurate when related to the fundamental (instead of dominant) frequency, as estimated by the algorithm (p <; 0.05 comparing f0 estimated by DFA and by FOA). FOA yields a more detailed and robust spectral description of EGM compared to DFA and OA parameters.
Heart rate turbulence (HRT) is a transient acceleration and subsequent deceleration of the heart rate after a premature ventricular complex (PVC), and it has been shown to be a strong risk stratification criterion in patients with cardiac disease. In order to reduce the noise level of the HRT signal, conventional measurements of HRT use a patient-averaged template of post-PVC tachogram (PPT), hence providing with long-term HRT indexes. We hypothesize that the reduction of the noise level at each isolated PPT, using signal processing techniques, will allow us to estimate short-term HRT indexes. Accordingly, its application could be extended to patients with reduced number of available PPT. In this paper, several HRT denoising procedures are proposed and tested, with special attention to support vector machine (SVM) estimation, as this is a robust algorithm that allows us to deal with few available time samples in the PPT. Pacing-stimulated HRT during electrophysiological study are used as a low-noise gold standard. Measurements in a 24-h Holter patient database reveal a significant reduction in the bias and the variance of HRT measurements. We conclude that SVM denoising yields short-term HRT measurements and improves the signal-to-noise level of long-term HRT measurements.