Mohamed Fayaz Khan

Dr. Mohamed Fayaz Khan

Centre for Power and Energy Systems, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
FMFranck Cinyama Mushid
Franck Cinyama Mushid
Mohamed Fayaz KhanMohamed Fayaz Khan
Mohamed Fayaz Khan
The integration of distributed energy resources into distribution networks creates operational challenges, including voltage instability and power quality issues. While battery energy storage systems (BESSs) can address these challenges, research has focused primarily on transmission-level applications or single services. This paper bridges this gap through a comprehensive review of BESS technologies and control strategies for multi-service ancillary support in distribution networks. Real-world case studies demonstrate BESS effectiveness: Hydro-Québec’s 1.2 MW system maintained voltage within 5% and responded to frequency events in under 10 ms; Germany’s hybrid 5 MW M5BAT project optimized multiple battery chemistries for different services; and South Africa’s Eskom deployment improved renewable hosting capacity by 15–70% using modular BESS units. The analysis reveals grid-forming inverters and hierarchical control architectures as critical enablers, with model predictive control optimizing performance and droop control ensuring robustness. However, challenges like battery degradation, regulatory barriers, and high costs persist. This paper identifies future research directions in degradation-aware dispatch, cyber-resilient control, and market-based valuation of BESS flexibility services. By combining theoretical analysis with empirical results from international deployments, this study provides utilities and policymakers with actionable insights for implementing BESS in modern distribution grids.

8 August 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
FMFranck Cinyama Mushid
Franck Cinyama Mushid
Mohamed Fayaz KhanMohamed Fayaz Khan
Mohamed Fayaz Khan
The integration of distributed energy resources into distribution networks creates operational challenges, including voltage instability and power quality issues. While battery energy storage systems (BESS) can address these challenges, research has focused primarily on transmission-level applications or single services. This paper bridges this gap through a comprehensive review of BESS technologies and control strategies for multi-service ancillary support in distribution networks. Real-world case studies demonstrate BESS effectiveness: Hydro-Québec’s 1.2 MW system maintained voltage within 5% and responded to frequency events in under 10 ms; Germany’s hybrid 5 MW M5BAT project optimized multiple battery chemistries for different services; and South Africa’s Eskom deployment improved renewable hosting capacity by 15 − 70% using modular BESS units. The analysis reveals grid-forming inverters and hierarchical control architectures as critical enablers, with model predictive control optimizing performance and droop control ensuring robustness. However, challenges like battery degradation, regulatory barriers, and high costs persist. The paper identifies future research directions in degradation-aware dispatch, cyber-resilient control, and market-based valuation of BESS flexibility services. By combining theoretical analysis with empirical results from international deployments, this study provides utilities and policymakers with actionable insights for implementing BESS in modern distribution grids.

6 September 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
OLOlanrewaju Adedamola Lasabi
Olanrewaju Adedamola Lasabi
ASAndrew Swanson
Andrew Swanson
Leigh JarvisLeigh Jarvis
Leigh Jarvis
Mohamed Fayaz KhanMohamed Fayaz Khan
Mohamed Fayaz Khan
AAAnuoluwapo Oluwatobiloba Aluko
Anuoluwapo Oluwatobiloba Aluko
Islanded DC microgrids are poised to become a crucial component in the advancement of smart energy systems. They achieve this by effectively and seamlessly integrating multiple renewable energy resources to meet specific load requirements through droop control, which ensures fair distribution of load current across the distributed energy resources (DERs). Employing droop control usually results in a DC bus voltage drop. This article introduces a secondary distributed control approach aimed at concurrently achieving current distribution among the DERs and regulating the voltage of the DC bus. The proposed secondary control approach eradicates voltage fluctuations and guarantees equitable current allocation by integrating voltage and current errors within the designed control loop. A novel hybrid particle swarm optimization–grey wolf optimization (HPSO-GWO) has been proposed, which assists in selecting the parameters of the distributed control technique, enabling the achievement of the proposed control objectives. Eigenvalue observation analysis has been utilized through the DC microgrid state-space model designed to assess the influence of the optimized distributed secondary control on the microgrid stability. A real-time testing system was constructed within MATLAB/Simulink® and deployed on Speedgoat™ real-time equipment to validate the operations of the proposed technique for practical applications. The results indicated that the proposed secondary control effectively enhances voltage recovery and ensures proper current distribution following various disturbances, thereby maintaining a continuous power supply. The outcomes also demonstrated the capabilities of the control approach in accomplishing the control objectives within the DC microgrid, characterized by minimal oscillations, overshoots/undershoots, and rapid time responses.

23 January 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Mohamed Fayaz KhanMohamed Fayaz Khan
Mohamed Fayaz Khan
Leigh JarvisLeigh Jarvis
Leigh Jarvis
EYEdward Andrew Young
Edward Andrew Young
ASAndrew Swanson
Andrew Swanson
JAJonathan Celvin Archer
Jonathan Celvin Archer
RSRobert G. Stephen
Robert G. Stephen
A desktop superconducting series core reactor (SSR), made from YBCO tape, is to serve as a precursor to a scaled up, grid-connected prototype unit. The SSR is intended as an alternative to traditionally employed technologies, including superconducting fault current limiters, when managing fault levels on the electrical power grid. The philosophy of connecting a prototype SSR at a grid connected research site is first presented before the focus shifts to the desktop SSR. The desktop SSR is a development step before the prototype unit as it will confirm design construction methodologies and functionality. The desktop SSR is compared to a copper reactor of similar geometry and both its fault limiting performance and reduced power consumption. It was found that the SSR reduced the impact of the applied fault comparably to the air core reactor (5. 9 % variance) and was more than four times more energy efficient. Another significant advantage of the SSR would be the significantly reduced footprint required in a typical substation yard.

24 July 2025 in IEEE Access
Verified
Journal Article
Open access
PMPeter Munyao Mutuku
Peter Munyao Mutuku
Leigh JarvisLeigh Jarvis
Leigh Jarvis
ASAndrew Swanson
Andrew Swanson
Mohamed Fayaz KhanMohamed Fayaz Khan
Mohamed Fayaz Khan
Open source modeling has emerged as a transformative paradigm in energy and power systems studies by enabling transparent, reproducible and collaborative development of tools and models. However, limited access to high-resolution, localized input data restricts the accuracy and contextual relevance of many models, especially in regions with diverse climatic and infrastructural conditions. This paper introduces a novel, systematic Open Source Modeling Method for Energy and Power Systems (OSM-MEPS). Derived and synthesized from foundational steps outlined in modeling literature, OSM-MEPS is grounded in first-principles thinking, the scientific method and the engineering design process frameworks, ensuring technical rigor, empirical validation and adaptability. To demonstrate effectiveness, OSM-MEPS guided the modeling and simulation of a solar photovoltaic (PV) system using high-resolution weather and irradiance data for the year 2024 from Solcast-DNV. At the Serres-C site in Greece, OSM-MEPS model results achieved a strong fit with real-world solar PV energy data (MAE: 469.57 kWh, RMSE: 584.62 kWh, R2: 0.887), outperforming PVLIB (MAE: 1,400.39 kWh, RMSE: 1,526.11 kWh, R2: 0.232). Seasonal testing showed similar results: in May 2024, the OSM-MEPS model achieved R2: 0.917 vs. PVLIB’s –0.039; in December, it maintained R2: 0.873 vs. PVLIB’s 0.638. Geographic validation demonstrated generalizability. In Pretoria, the OSM-MEPS model outperformed PVLIB (R2: 0.443 vs. –0.239); in Adelaide, it maintained accuracy (R2: 0.866) while PVLIB failed (R2: –0.959). In Kisumu, both models had low correlation despite matching MAE (0.88 kWh), due to data gaps and limited shading metadata. A rooftop energy feasibility study was carried out in Njagu-Mhasibu-Ruiru Estate in Kenya, based on a solar PV installed capacity of 8.75 kW. The OSM-MEPS model predicted an annual yield of 14,329 kWh/year, compared to PVLIB’s estimate of 10,048 kWh/year and the GSA reference of 12,784 kWh/year. Overall, the results confirm that the OSM-MEPS method and its resulting model are robust and adaptable tools for high-resolution solar PV energy modeling across diverse geographic regions and weather conditions.

28 May 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
FBFrancis Jeremy Bennie
Francis Jeremy Bennie
Mohamed Fayaz KhanMohamed Fayaz Khan
Mohamed Fayaz Khan
ASAndrew Swanson
Andrew Swanson
The increasing penetration of inverter-based distributed energy resources (DERs) within distribution networks has resulted in harmonic distortion risks that can affect transformer thermal loading, service life, and network hosting capacity. This study assesses harmonic behaviour under increasing DER penetration using a detailed MATLAB 2025b/Simulink model of the CIGRÉ low-voltage benchmark feeder, adapted to reflect representative network parameters and run at a 400 V point of common coupling (PCC). DER penetration is incrementally increased from 0% to 195% of feeder load, and for each penetration level the PCC currents and voltages are examined using FFT-based spectrum extraction. The short-circuit strength is first calculated (I_SC/I_L = 14.1), and harmonic current and voltage distortion thresholds are benchmarked against IEEE 519:2022 and NRS 048-2:2025 respectively. Results show that while DER inverters introduce increasing odd-order harmonics, mainly the 3rd, 5th, 7th and 11th, the feeder’s moderate short-circuit capacity suppresses PCC voltage distortion, keeping voltage THD below 3% across all scenarios. As the inverter-based DER penetration increases, so does the harmonic current distortion. At 180%, Total Demand Distortion (TDD) nears the IEEE limit of 5%.