Andrew Swanson

Dr. Andrew Swanson

University of KwaZulu-Natal
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
AAAjibola Akinrinde
Ajibola Akinrinde
ASAndrew Swanson
Andrew Swanson
RTRemy Tiako
Remy Tiako
In this paper the dynamic behavior of different wind turbine generator configurations including doubly fed induction generators (DFIG), squirrel cage induction generator (SCIG), wound rotor induction generator (WRIG), and permanent magnet synchronous generator (PMSG) under ferroresonant conditions of energization and de-energization was investigated using Simulink/MATLAB (version 2017B, MathWorks, Natick, MA, USA). The result showed that SCIG had the highest overvoltage of 10.1 PU during energization, followed by WRIG and PMSG, while the least was DFIG. During de-energization, PMSG had the highest overvoltage of 9.58 PU while WRIG had the least. Characterization of the ferroresonance was done using a phase plane diagram to identify the harmfulness of the ferroresonance existing in the system. It was observed that for most of the wind turbine configurations, a chaotic mode of ferroresonance exists for both energization and de-energization scenarios. Although overvoltage during energization for wind turbine generator configurations was higher than in the de-energization with an exception of PMSG, their phase plane diagrams showed that de-energization scenarios were more chaotic than energization scenarios. The study showed that WRIG was the least susceptible to ferroresonance while PMSG was the most susceptible to ferroresonance.

1 March 2017 in Applied Energy
Verified
Journal Article
Closed access
ARMAN GOUDARZIARMAN GOUDARZI
ARMAN GOUDARZI
ASAndrew Swanson
Andrew Swanson
JCJohn Van Coller
John Van Coller
PSPierluigi Siano
Pierluigi Siano

27 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
AAAnuoluwapo Oluwatobiloba Aluko
Anuoluwapo Oluwatobiloba Aluko
ASAndrew Swanson
Andrew Swanson
Leigh JarvisLeigh Jarvis
Leigh Jarvis
DDDavid Dorrell
David Dorrell
Stand-alone DC microgrids have multiple distributed generation (DG) sources that meet the required demand (load) by using droop control to achieve load (current) sharing between the DGs. The use of droop control leads to a voltage drop at the DC bus. This paper presents a distributed secondary control scheme to simultaneously ensure current sharing between the DGs and regulate the DC bus voltage. The proposed control scheme eliminates the voltage deviation and ensures balanced current sharing by combining the voltage and current errors in the designed secondary control loop. A new flight-based artificial bee colony optimization algorithm is proposed. This selects the parameters of the distributed secondary control scheme to achieve the objectives of the proposed controller. A state–space model of the DC microgrid is developed by using eigenvalue observation to test the impacts of the proposed optimized distributed secondary controller on the stability of the DC microgrid system. A real-time test system is developed in MATLAB/Simulink and used in a Speedgoat real-time simulator to verify the performance of the proposed control scheme for real-world applications. The results show the robustness of the proposed distributed secondary control scheme in achieving balance current sharing and voltage regulation in the DC microgrid with minimal oscillations and fast response time.


27 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
AAAjibola Akinrinde
Ajibola Akinrinde
ASAndrew Swanson
Andrew Swanson
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
The Ferranti effect could cause a rise in voltage along the cables on a wind farm if the circuit breakers at the receiving ends are switched off. Ferroresonance could also occur due to stuck pole(s) of the circuit breaker during de-energization. This paper reports on the temporary overvoltage (TOV) arising from the de-energization of the circuit breaker connecting the wind turbine to the feeder, the feeder breaker connecting an array of wind turbines to the point of common coupling (PCC), and the opening of the circuit breaker connecting the onshore to the offshore substation. Ferroresonance was characterized using a phase plane diagram and Poincaré map and was identified to be chaotic. The effect of the nonlinear characteristic of the wind transformer core on the ferroresonant overvoltage was examined and increased with the steepness of slope of the transformer curve. A damping resistor, shunt reactor and surge arrester were used to mitigate the overvoltage experienced during the ferroresonant event. The damping resistor was able to reduce the overvoltage to 1.24 P.U. and damped the ferroresonance from chaotic to fundamental mode.

27 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OLOlanrewaju Adedamola Lasabi
Olanrewaju Adedamola Lasabi
ASAndrew Swanson
Andrew Swanson
Leigh JarvisLeigh Jarvis
Leigh Jarvis
AAAnuoluwapo Oluwatobiloba Aluko
Anuoluwapo Oluwatobiloba Aluko
MBMatthew Brown
Matthew Brown
There is a growing focus on exploring direct current (DC) microgrids in traditional power grids. A key challenge in operating these microgrids is ensuring proper current distribution among converters. While conventional droop control has been used to address this issue, it requires compensating for voltage deviations in the DC bus. This paper introduces an innovative distributed secondary control approach that effectively addresses both voltage restoration and current sharing challenges within a standalone DC microgrid. The distributed secondary control proposed in this study is integrated into the microgrid’s cyber layer, enabling information sharing between controllers. This distributed approach ensures reliability, even in the event of partial communication connection failures. The controller employs a fuzzy logic control approach to dynamically determine the parameters of the secondary control, resulting in an enhanced control response. Additionally, the proposed approach can handle constant power and resistive loads without specific requirements. Employing the Lyapunov method, we have derived adequate stability conditions for the proposed controller. The performance of the controller has been assessed using MATLAB/Simulink® models and validated with real-time experimental testing performed with a SpeedgoatTM real-time machine, considering five different test cases. The results indicated that the proposed control system is robust in achieving its control objectives within a DC microgrid, exhibiting fast response and minimal oscillations.