Giuseppe Prisco

Dr. Giuseppe Prisco


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
GPGiuseppe Prisco
Giuseppe Prisco
MPMaria Agnese Pirozzi
Maria Agnese Pirozzi
ASAntonella Santone
Antonella Santone
FEFabrizio Esposito
Fabrizio Esposito
Mario CesarelliMario Cesarelli
Mario Cesarelli
Leandro DonisiLeandro Donisi
Leandro Donisi
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland–Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.

8 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
GPGiuseppe Prisco
Giuseppe Prisco
MRMaria Romano
Maria Romano
FEFabrizio Esposito
Fabrizio Esposito
Mario CesarelliMario Cesarelli
Mario Cesarelli
ASAntonella Santone
Antonella Santone
Francesco AmatoFrancesco Amato
Francesco Amato
Occupational ergonomics aims to optimize the work environment and to enhance both productivity and worker well-being. Work-related exposure assessment, such as lifting loads, is a crucial aspect of this discipline, as it involves the evaluation of physical stressors and their impact on workers’ health and safety, in order to prevent the development of musculoskeletal pathologies. In this study, we explore the feasibility of machine learning (ML) algorithms, fed with time- and frequency-domain features extracted from inertial signals (linear acceleration and angular velocity), to automatically and accurately discriminate safe and unsafe postures during weight lifting tasks. The signals were acquired by means of one inertial measurement unit (IMU) placed on the sternums of 15 subjects, and subsequently segmented to extract several time- and frequency-domain features. A supervised dataset, including the extracted features, was used to feed several ML models and to assess their prediction power. Interesting results in terms of evaluation metrics for a binary safe/unsafe posture classification were obtained with the logistic regression algorithm, which outperformed the others, with accuracy and area under the receiver operating characteristic curve values of up to 96% and 99%, respectively. This result indicates the feasibility of the proposed methodology—based on a single inertial sensor and artificial intelligence—to discriminate safe/unsafe postures associated with load lifting activities. Future investigation in a wider study population and using additional lifting scenarios could confirm the potentiality of the proposed methodology, supporting its applicability in the occupational ergonomics field.

6 March 2009 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
MDM. D'Urso
M. D'Urso
GPGiuseppe Prisco
Giuseppe Prisco
MCM. Cicolani
M. Cicolani
A flexible approach for the synthesis of sparse arrays able to radiate plane waves in near-zone is proposed. In particular, the array dimension, the array element positions, and their weights are determined such to achieve the desired goal. Unlike existing techniques, the proposed one completely avoids the need for global optimizations, thus saving computational time and costs. Numerical examples, confirming potentialities of the proposed tools and algorithms, are discussed.

20 September 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Leandro DonisiLeandro Donisi
Leandro Donisi
DJDeborah Jacob
Deborah Jacob
Lorena GuerriniLorena Guerrini
Lorena Guerrini
GPGiuseppe Prisco
Giuseppe Prisco
FEFabrizio Esposito
Fabrizio Esposito
PGPaolo Gargiulo
Paolo Gargiulo
Manual material handling and load lifting are activities that can cause work-related musculoskeletal disorders. For this reason, the National Institute for Occupational Safety and Health proposed an equation depending on the following parameters: intensity, duration, frequency, and geometric characteristics associated with the load lifting. In this paper, we explore the feasibility of several Machine Learning (ML) algorithms, fed with frequency-domain features extracted from electromyographic (EMG) signals of back muscles, to discriminate biomechanical risk classes defined by the Revised NIOSH Lifting Equation. The EMG signals of the multifidus and erector spinae muscles were acquired by means of a wearable device for surface EMG and then segmented to extract several frequency-domain features relating to the Total Power Spectrum of the EMG signal. These features were fed to several ML algorithms to assess their prediction power. The ML algorithms produced interesting results in the classification task, with the Support Vector Machine algorithm outperforming the others with accuracy and Area under the Receiver Operating Characteristic Curve values of up to 0.985. Moreover, a correlation between muscular fatigue and risky lifting activities was found. These results showed the feasibility of the proposed methodology—based on wearable sensors and artificial intelligence—to predict the biomechanical risk associated with load lifting. A future investigation on an enriched study population and additional lifting scenarios could confirm the potential of the proposed methodology and its applicability in the field of occupational ergonomics.

4 January 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
GPGiuseppe Prisco
Giuseppe Prisco
MPMaria Agnese Pirozzi
Maria Agnese Pirozzi
ASAntonella Santone
Antonella Santone
Mario CesarelliMario Cesarelli
Mario Cesarelli
FEFabrizio Esposito
Fabrizio Esposito
Leandro DonisiLeandro Donisi
Leandro Donisi
Background/Objectives: Long-term work-related musculoskeletal disorders are predominantly influenced by factors such as the duration, intensity, and repetitive nature of load lifting. Although traditional ergonomic assessment tools can be effective, they are often challenging and complex to apply due to the absence of a streamlined, standardized framework. Recently, integrating wearable sensors with artificial intelligence has emerged as a promising approach to effectively monitor and mitigate biomechanical risks. This study aimed to evaluate the potential of machine learning models, trained on postural sway metrics derived from an inertial measurement unit (IMU) placed at the lumbar region, to classify risk levels associated with load lifting based on the Revised NIOSH Lifting Equation. Methods: To compute postural sway parameters, the IMU captured acceleration data in both anteroposterior and mediolateral directions, aligning closely with the body’s center of mass. Eight participants undertook two scenarios, each involving twenty consecutive lifting tasks. Eight machine learning classifiers were tested utilizing two validation strategies, with the Gradient Boost Tree algorithm achieving the highest accuracy and an Area under the ROC Curve of 91.2% and 94.5%, respectively. Additionally, feature importance analysis was conducted to identify the most influential sway parameters and directions. Results: The results indicate that the combination of sway metrics and the Gradient Boost model offers a feasible approach for predicting biomechanical risks in load lifting. Conclusions: Further studies with a broader participant pool and varied lifting conditions could enhance the applicability of this method in occupational ergonomics.

1 May 2011
Verified
Conference Paper
Closed access
ABAmedeo Buonanno
Amedeo Buonanno
MDM. D'Urso
M. D'Urso
MFM. Felaco
M. Felaco
GPGiuseppe Prisco
Giuseppe Prisco
Leopoldo AngrisaniLeopoldo Angrisani
Leopoldo Angrisani
Rosario Schiano Lo MorielloRosario Schiano Lo Moriello
Rosario Schiano Lo Moriello
A through-wall imaging problem for a 2-D geometry is considered. A new method for through the wall detection and tracking of hidden targets (e.g. human bodies in rescue missions) in two-dimensional scenes, by using radio frequency signals, is presented. In particular, a new approach is proposed and discussed, mainly based on a multisensor system and an advanced imaging technique, which properly exploits a regularized linear inversion scheme. Numerical and experimental tests were conducted to assess the performance and capabilities of the proposed approach.