Polymers of intrinsic microporosity (PIMs) have promising gas adsorption properties for potential applications such as incorporation into high-pressure hydrogen storage tanks in an effort to increase the storage capacity or decrease the operating pressure. Such applications require detailed mechanical characterisation and determination of the structure-properties relationships to enable optimisation of the interface between the polymer and the tank. In this study, we show that Atomic Force Microscopy (AFM) nanoindentation can be used to determine the elastic modulus of cast PIM-1 films and that this property is depth-dependent. Average values of elastic modulus obtained experimentally were 1.87 GPa and are compared with elastic tensile modulus and storage tensile modulus obtained in previous studies. In addition, Scanning Electron Microscopy (SEM) and AFM imaging was performed to investigate the surface structure of the cast PIM-1 film, which has been shown to be highly granular
The paper presents a new control algorithm which consists of a combination of an adaptive control structure and a model predictive one. An atomic force microscope in the contact mode (AFM) is considered to validate the proposed algorithm. The AFM is a powerful tool to measure the topography of the sample at the scale of a few nanometers, where a small sharp tip supported in a micro cantilever scans the surface. In the contact mode the samples topography is obtained while the closed-loop control holding the tip sample force constant. The dynamics of the tip-sample system is very complex with different kinds of forces that act between the tip and the sample. Here the dominated force depends on the distance tip-sample and in the present work we use a modified Hertz model to describe the non-linear force when the distance tip-sample is less than 20 nm. The proposed control technique consists of a two stage structure algorithm. In the control strategy, the adaptive part is devoted to the control of the non-linear dynamics, the model predictive part improves the transient of the overall control system in order to have a fast control of the complex tip-sample system. The procedure is totally general and can be applied to any drive system.
Define intelligent control is not an easy task, in the literature we find different definitions of it, which depend on the area of application. Here we will define or view the intelligent control in the context of the control of complex systems. In this context, a control is intelligent when it has the ability to operate and act to control in the best way a complex system which changed suddenly and significantly, due to external and internal disturbances. This work presents the reconfigurable control method based on adaptive and conventional control combined with the “multiples models, switching and tuning” (MMST), which can identify the model which best represent the complex system. The approach was first introduced by Narendra and Balakrishnan. Here we propose two different control strategies, one is based on conventional control using MMST and the second is based on the combination of adaptive and conventional control using MMST, to control a complex system which varies its structure and parameters. The proof of the Lyapunov stability is not part of this work, for a proof see the work of Narendra and Balakrishnan. We assume that the models of the variable plant were identified before. In the simulation we used it to represent the dynamic change of the plant. The aim of the work is to investigate if the reconfigurable control can act in an intelligent way and control in a stable manner the time variable structure system. We present some simulations results to show the efficacy of the proposed control strategies.
In the literature we found different kind of film conducting polymers, as Polyaniline (PANI) or Polypyrrole (PPY), used as sensor element integrated in a Field Effect Transistor (FET) for the detection of gas or photogenes. In this work we proposed a sensor system prototype based on the combination of a coplanar micro strip (CPμS) waveguide and polymer nanofibers met (electrospun) called, CPμS/PNW sensor system, for target element (bio element or gas) detection. The detection idea is based on the impedance change measurement in the frequency range. The first step toward to develop the sensor is to investigate and understand the low frequency (0.1 to 1 MHz) electrodynamics response properties of the CPμS waveguide with (CPμS/PNW) and without nanofibers. We develop a transmission line mathematical model to describe the CPμS/PNW sensor system, the mathematical model was simulated with Scilab and the results were compared with the CPμS/PNW experimental data to see the degree of agreement between model and experiment. The impedance curves obtained from the experimental data show a good agreement with the model, which predict CPμS/PNW (CPμS + electrospun) impedance curve lower than the CPμS impedance curve. The electronics property (impedance) of the PEO electrospun was calculated from the difference between both impedance curves, this difference represent the polymer nanofibers mat impedance. The curves exhibited approximately a sub-linear power law decrease with frequency, which is consistent with the behavior found in polymers. The polymer nanofibers mat was produced by electrospinning method, where the diameter of the nanofibers obtained are in the range of 100 nm and 900 nm.
Electrospinning is a versatile technique widely used in biomedicine and electronics. Here we describe the design and construction of a low-cost Near-Field Electrospinning System (NFES) using open-source technologies, including 3D printing and open-source hardware and software. The system features a modified 3D printer for precise needle and mobile collector control, along with an Arduino-driven syringe pump to regulate the flow of the polymeric solution. A custom user interface ensures optimal conditions during operation. Proof-of-concept tests demonstrate the system capability to fabricate and functionalize microfibers using a polyethylene oxide solution in distilled water.
The paper presents a model reference adaptive control (MRAC) of first and second order to control the nonlinear dynamics of an atomic force microscope (AFM) cantilever, which is operated in contact mode. The AFM is a powerful tool to measure the topography of a sample at the scale of a few nanometers, where a small sharp tip supported in a micro cantilever scans the surface. In the contact mode the sample's topography is obtained by using the closed-loop control that holds the tip sample force constant. The nonlinear dynamics of the tip-sample system is very complex with different kinds of nonlinear forces that act between the tip and the sample. Here the dominated force depends on the distance tip-sample. In the present work we use a modified Hertz model to describe the nonlinear force when the distance tip-sample is less than 1 nm. First the complex nonlinear tip-sample system is controlled with a nonlinear MRAC of 1st order and after with a nonlinear MRAC of 2nd order. The results of both control strategies were compared in order to see which one gives a better control perfomance. Here a stability proof for both MRAC methods is present. A variety of simulation results are presented to demonstrate the efficacy of the proposed methods. The procedure is general and can be applied to any nonlinear system.