The principal issue associated with wind parks (WPs) based on doubly-fed induction generators (DFIGs) is their vulnerability to network faults. This paper presents a novel non-linear forward power controller design with an adaptive backstepping command using parametric estimation (NFPC_ABC-PE) to enhance fault ride-through (FRT) capacities in WP utilizing DFIGs. The suggested NFPC_ABC-PE manupiles both rotor and network-side power converters (i.e., RSPCs and NSPCs). Specifically, RSPCs are manipulated to maintain the targeted voltage at dc-bus terminals, while NSPCs are manipulated to supply the reactive energy (power) necessary if the network is disturbed. As a result, the NFPC_ABC-PE proposed precisely supplies energy reactively to ensure the smooth execution of FRT ability. The method developed comprehends the dynamics of RSPC, NSPC-side filters, and DC-bus terminal voltage in the form of electrical active and reactive output power. The parameters of the RSPC and NSPC-side filters, including those associated with the dc-bus condenser, are regarded as entirely unknown. To estimate and regulate these parameters, adaptation algorithms are utilized. The NFPC_ABC-PE employs parameter adaptation algorithms and switching control inputs designed to safeguard the overall stability of WP. The stability analysis of the DFIG-based WPs with the proposed NFPC_ABC-PE involves applying stability in the sense of the Lyapunov function (LF). To validate its efficacy, simulations are carried out on a single 10 MW power generation unit. The results of the simulation highlight a clear enhancement in the stability and FRT capability of WP, contrasting with the non-linear forward power controller employing the sliding mode command (NFPC-SMC).
Multi-level inverters are widely employed to generate new energy because of their huge capacity and benefits in sound control performance. One of the critical areas of study for multi-level inverters is control strategy research. In this study, the control strategy for a multi-level inverter—which is frequently employed in HVDC and FACTS systems—is designed. An asymmetrical D.C. voltage source is supplied to create the appropriate output voltage waveform with fewer total harmonic distortions (THDs) at the output voltage and current waveforms. In this work, the pulse width modulation techniques of POD (phase opposition disposition) and APOD (alternative phase opposition disposition) MC PWM are applied to a multi-level inverter to generate the seven-level output voltage waveform. This study presents an enhanced variable carrier frequency APOD control approach that can successfully lower the overall harmonic distortion rate. The design and completion of the phase-shifting POD and APOD control strategies are followed by an analysis and comparison of the THD situation under various switching frequencies and a simulation and verification of the control strategy using MATLAB simulation. The TI DSP-based control approach has been programmed. The APOD technique increases the output voltage’s THD to 18.27%, while the output current waveform’s THD is reduced to 15.67% by utilizing the APOD PWM technique. Using the POD PWM approach increases the total harmonic distortion (THD) of the voltage waveform by 18.06% and the output current waveform’s THD by 15.45%.
With the increase in reliance on doubly fed induction generator-based wind energy conversion systems (DFIG-WECSs), extracting maximum power from wind energy and enhancing fault ride-through (FRT) techniques meeting the grid code requirements is the foremost concern. This paper proposes a modified control scheme that operates in normal running conditions and during faults as a dual mode. The proposed control scheme operates in a coordinated wind speed estimation-based maximum power point tracking (WSE-MPPT) mode during normal running conditions to extract maximum power from wind energy and enhances the crowbar rotor active impedance-based FRT mode during faults. The proposed technique controls the rotor side converter (RSC) parameters during faults by limiting the transient surge in the rotor and stator currents. In this study, the transient behavior of the proposed technique is analyzed under a three-phase symmetrical fault with a severe voltage dip, and it is observed that, when the fault is over and the RSC is activated and connected to the system, a large inrush current is produced with transient oscillations; the proposed scheme suppresses this post-fault inrush current and limits the transient oscillation. During the FRT operating mode under a symmetrical fault, the simulation results of the proposed technique are validated by the conventional crowbar strategy. In contrast, during the WSE-MPPT operating mode under normal running conditions, a smooth achievement of system parameters after starting the inrush period to a steady state at fixed wind speed is observed.
Solid-state transformer (SST) has gained increasing attention in the electrical grid. One of the SST architectures is a three stages SST where quadrable active bridge (QAB) can be used in the isolation stage. This work investigates power and voltage regulation of the QAB module-based SST design under unbalanced loading conditions. The proposed control system applied in the QAB implements an adaptive linear quadratic regulator (ALQR) and nonlinear model predictive control (NMPC) to achieve the regulation. The dynamic performance of the QAB based SST is proven analytically and supported by simulation results.
Sustainable energy management is achieved through seamless power distribution, satisfying user demands. The swift integration of renewable energy sources sustains the sustainability of smart grid (SG) architectures. This article introduces a Temporal Evolution Network-Learning (TEN-L) model that aims to achieve the aforementioned sustainability in smart grids by integrating renewable resources. The model addresses the rising energy demand driven by environmental impacts, resource depletion, and power outages. TEN-L employs a graph-based evaluation method and an evolutionary optimization to enhance sustainability and distribution efficiency while reducing power losses. The model evaluates the relationship between sustainability factors and distribution efficiency over time, while adjusting the integration of renewable energy sources to accommodate fluctuating demand. By optimizing energy source selection and distribution parameters, TEN-L enhances the reliability and sustainability of smart grid operations. This proposed model achieves a 12.27% higher demand response and an 11.63% higher distribution efficiency for the average hours considered.
The increasing complexity of modern power systems, driven by the integration of renewable energy sources and growing electricity demand, has led to a need for optimizing smart grids. Traditional grid management approaches are often insufficient in addressing the challenges of efficiency, reliability, and minimizing losses. In this paper, we propose a novel AI-based optimization framework for smart grids, designed to reduce transmission and distribution losses, enhance system efficiency, and improve grid reliability. We conduct a comparative analysis of traditional optimization techniques and state-of-the-art AI algorithms and demonstrate the superiority of the proposed method using the IEEE 33-bus benchmark system. Results show a significant reduction in power losses and an improvement in voltage profile, leading to a more efficient and reliable grid.