Ulrich Biber

Dr. Ulrich Biber

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2011 in PLOS ONE
Verified
Journal Article
Open access
PDF file
UBUlrich Biber
Ulrich Biber
Uwe IlgUwe Ilg
Uwe Ilg
Eye movements create an ever-changing image of the world on the retina. In particular, frequent saccades call for a compensatory mechanism to transform the changing visual information into a stable percept. To this end, the brain presumably uses internal copies of motor commands. Electrophysiological recordings of visual neurons in the primate lateral intraparietal cortex, the frontal eye fields, and the superior colliculus suggest that the receptive fields (RFs) of special neurons shift towards their post-saccadic positions before the onset of a saccade. However, the perceptual consequences of these shifts remain controversial. We wanted to test in humans whether a remapping of motion adaptation occurs in visual perception. The motion aftereffect (MAE) occurs after viewing of a moving stimulus as an apparent movement to the opposite direction. We designed a saccade paradigm suitable for revealing pre-saccadic remapping of the MAE. Indeed, a transfer of motion adaptation from pre-saccadic to post-saccadic position could be observed when subjects prepared saccades. In the remapping condition, the strength of the MAE was comparable to the effect measured in a control condition (33±7% vs. 27±4%). Contrary, after a saccade or without saccade planning, the MAE was weak or absent when adaptation and test stimulus were located at different retinal locations, i.e. the effect was clearly retinotopic. Regarding visual cognition, our study reveals for the first time predictive remapping of the MAE but no spatiotopic transfer across saccades. Since the cortical sites involved in motion adaptation in primates are most likely the primary visual cortex and the middle temporal area (MT/V5) corresponding to human MT, our results suggest that pre-saccadic remapping extends to these areas, which have been associated with strict retinotopy and therefore with classical RF organization. The pre-saccadic transfer of visual features demonstrated here may be a crucial determinant for a stable percept despite saccades.

30 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JJJérémie Jacques
Jérémie Jacques
HNHorst Neuhaus
Horst Neuhaus
MEMarkus Enderle
Markus Enderle
UBUlrich Biber
Ulrich Biber
WLWalter Linzenbold
Walter Linzenbold
ARAlessandro Repici
Alessandro Repici
Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60–65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife® flex T-Type (HK-T) and the Olympus DualKnife® J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.

31 March 2008 in Vision Research
Verified
Journal Article
Closed access
UBUlrich Biber
Ulrich Biber
Uwe IlgUwe Ilg
Uwe Ilg

5 November 2019 in BMC Surgery
Verified
Journal Article
Open access
PDF file
BKBernhard Kraemer
Bernhard Kraemer
CTChristos Tsaousidis
Christos Tsaousidis
SKStephan Kruck
Stephan Kruck
MSMartin Schenk
Martin Schenk
MSMarcus Scharpf
Marcus Scharpf
UBUlrich Biber
Ulrich Biber
Background: Electrosurgical vessel sealers are gradually replacing conventional techniques such as ligation and clipping. Algorithms that control electrosurgical units (ESU), known as modes, are important for applications in different surgical disciplines. This chronic porcine animal study aimed to evaluate the safety and effectiveness of the novel thermoSEAL electrosurgical vessel sealing mode (TSM). The BiClamp® mode (BCM) of the renowned VIO® 300 D ESU served as control. BCM has been widely available since 2002 and has since been successfully used in many surgical disciplines. The TSM, for the novel VIO® 3 ESU, was developed to reduce sealing time and/or thermal lateral spread adjacent to the seal while maintaining clinical success rates. The primary aim of this study was to investigate the long-term and intraoperative seal quality of TSM. Methods: The BiCision® device was used for vessel sealing with TSM and BCM in ten German Landrace pigs which underwent splenectomy and unilateral nephrectomy during the first intervention of the study. The seals were cut with the BiCision® knife. Ninety-nine arteries, veins and vascular bundles were chronically sealed for 5 or 21 days. Thereafter, during the second and terminal intervention of the study, 97 additional arteries and veins were sealed. The carotid arteries were used for histological evaluation of thermal spread. Results: After each survival period, no long-term complications occurred with either mode. The intraoperative seal failure rates, i.e. vessel leaking or residual blood flow after the first sealing activation, were 2% with TSM versus 6% with BCM (p = 0.28). The sealing time was significantly shorter with TSM (3.5 ± 0.69 s vs. 7.3 ± 1.3 s, p < 0.0001). The thermal spread and burst pressure of arteries sealed with both modes were similar (p = 0.18 and p = 0.61) and corresponded to the histological evaluation. The measured tissue sticking parameter was rare with both modes (p = 0.33). Tissue charring did not occur. Regarding the cut quality, 97% of the seals were severed in the first and 3% in the second attempt (both with TSM and BCM). Conclusions: The novel TSM seals blood vessels twice as fast as the BCM while maintaining excellent tissue effect and clinical success rates. Trial registration: Not applicable.

29 November 2024 in JGH Open
Verified
Journal Article
Open access
CKChristopher Khor
Christopher Khor
KIKatsuro Ichimasa
Katsuro Ichimasa
STStephen K K Tsao
Stephen K K Tsao
UBUlrich Biber
Ulrich Biber
YSYutaka Saito
Yutaka Saito
Background and Aim: Endoscopic submucosal dissection (ESD) is considered the best modality for achieving en bloc resection of larger neoplastic mucosal lesions in the upper and lower gastrointestinal (GI) tract. Multiple devices are available for ESD, and refinements continue to be made to develop devices that improve the safety and efficiency of performing ESD. Submucosal injection with viscous fluids like glycerol, which prolong submucosal expansion, could facilitate the procedure. We aimed to evaluate the safety and performance of the new Erbe HYBRIDknife® flex, which combines electrosurgical dissection with waterjet‐assisted injection in a slim and flexible form factor.Methods: In a prospective animal study with six pigs, four endoscopists, each with 10–20 years of experience in ESD, performed 28 esophageal ESDs. One half was performed with physiological saline injectate, the other half with fructose‐added glycerol. Various performance aspects were evaluated on a five‐point scale [5 = best], including dissection properties, handling, and usability.Results: No perforations or major bleeding occurred. All resections were performed en bloc, with one technical failure (3.6%, 1 of 28). Performance scores were similar for saline and glycerol (4.5 ± 0.31 vs. 4.5 ± 0.32, P = 0.36), as was dissection speed (13 ± 6.2 mm2/min vs. 15 ± 6.1 mm2/min, P = 0.22).Conclusions: We demonstrated that esophageal ESD can be performed safely and rapidly using HYBRIDknife flex, with excellent performance evaluation by the endoscopists. Combining this device with glycerol or saline is precise and effective for ESD, although experience could compensate for the theoretical disadvantage of using normal saline.

27 May 2020 in BMC Urology
Verified
Journal Article
Open access
PDF file
UBUlrich Biber
Ulrich Biber
OJOvidiu Jurjut
Ovidiu Jurjut
MEMarkus D. Enderle
Markus D. Enderle
WAWilhelm K. Aicher
Wilhelm K. Aicher
Background: During transurethral resection of bladder tumours (TURB), radio-frequency (RF) currents can lead to adverse neuromuscular stimulation (NMS). Here we present a novel ex vivo method to determine the risk of RF generators and their bipolar TURB modes to cause NMS. We aimed to develop an experimental platform for safety evaluation of new RF generators and their modes with a newly established test standard, suitable for replacement or reduction of animal testing. Methods: We tested four contemporary RF generators with their bipolar modes for TURB in saline. A two-stage ex vivo approach was pursued: First, we recorded voltages at possible positions of the obturator nerve behind a porcine bladder wall in a TURB model using 18 RF applications per generator. Second, these voltage records were used as stimuli to evoke nerve compound action potentials (CAPs) in isolated porcine axillary nerves. The NMS potential was defined as the ratio between the observed area under the CAPs and the theoretical CAP area at maximum response and a firing rate of 250 Hz, which would reliably induce tetanic muscle responses in most human subjects. The measurement protocol was tailored to optimise reproducibility of the obtained NMS potentials and longevity of the nerve specimens. Results: As prerequisite for the clinical translation of our results, the robustness of our test method and reproducibility of the NMS potential are demonstrated with an excellent correlation (r = 0.93) between two sets of identical stimuli (n = 72 each) obtained from 16 nerve segments with similar diameters (4.2 ± 0.37 mm) in the nerve model. The RF generators differed significantly (p < 0.0001) regarding NMS potential (medians: 0–3%). Conclusions: Our test method is suitable for quantifying the NMS potential of different electrosurgical systems ex vivo with high selectivity at a reasonable degree of standardization and with justifiable effort. Our results suggest that the clinical incidence of NMS is considerably influenced by the type of RF generator. Future generations of RF generators take advantage from the proposed test standard through higher safety and less animal testing. Health professionals and treated patients will benefit most from improved RF surgery using generators with a low NMS risk.