Walter Linzenbold

Dr. Walter Linzenbold

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in Respiration
Verified
Journal Article
Closed access
PDF file
JHJürgen Hetzel
Jürgen Hetzel
WLWalter Linzenbold
Walter Linzenbold
HBHans Boesmueller
Hans Boesmueller
MEMarkus Enderle
Markus Enderle
Venerino PolettiVenerino Poletti
Venerino Poletti
Background: Forceps biopsy (FB) is still the most popular procedure for the bronchoscopic sampling of lung tissue. However, it has limitations like inadequate sample size and crush artifacts. Cryobiopsy (CB) has been introduced to obtain bronchoscopic biopsies with improved diagnostic yield compared to FB. Limitations of CB are the need to retract the cryoprobe en bloc with bronchoscope because samples are larger than the working channel and the variations of the freezing power of the reusable CB (rCB). Therefore, 3 new disposable cryoprobes (dCB) have been developed with different outer diameters: 1.1 mm (CB11-S) that can be retracted through the working channel of the bronchoscope, 1.7 mm (CB17) and 2.4 mm (CB24n), respectively. Objectives: The aim was to evaluate the new cryoprobes with regard to feasibility, specimen area, specimen quality and complications. Methods: We compared biopsy samples of the new probes with those obtained by FB and by rCB in an in vivo (porcine) model. A flexible bronchoscope was used to perform biopsy at 4 different locations at the upper and lower lobes of the right and left lung, respectively. The biopsies were taken under fluoroscopic control. The biopsy tool and activation times were allocated randomly. Altogether 204 biopsy procedures were performed. Results: The sample quality of the dCB was superior to that of FB (all p < 0.05) and not significantly different to the rCB sample quality. Mean specimen sample area of all CB was significantly larger compared to FB (p < 0.05). The sample area of the small cryoprobe (CB11-S) was significantly smaller compared to the other CB probes (p < 0.05). No severe bleedings occurred. Pneumothoraces were detected in 3 of the 7 pigs. Conclusion: We conclude that CB with the new single-use instruments are feasible and represent a viable option to improve the diagnostic accuracy of histopathological evaluation compared to FB.

8 September 2021 in Cancers
Verified
Journal Article
Open access
PDF file
STSabrina Gloria Giulia Testoni
Sabrina Gloria Giulia Testoni
MPMaria Chiara Petrone
Maria Chiara Petrone
MRMichele Reni
Michele Reni
GRGemma Rossi
Gemma Rossi
MBMaurizio Barbera
Maurizio Barbera
PAPaolo Giorgio Arcidiacono
Paolo Giorgio Arcidiacono
Endoscopic ultrasound-ablation with HybridTherm-Probe (EUS-HTP) significantly reduces tumour volume (TV) in locally-advanced pancreatic ductal adenocarcinoma (LA-PDAC). We aimed at investigating the clinical efficacy of EUS-HTP plus chemotherapy versus chemotherapy (HTP-CT and CT arms) in LA- and borderline-resectable (BR) PDAC, with 6-months progression-free survival (6-PFS) rate as primary endpoint. In a phase-II randomized-controlled-trial, 33 LA/BR-PDAC patients per-arm were planned to verify 20% improved 6-PFS rate. Radiological response (Choi criteria), TV and serum CA19.9 were assessed up to 6-months. Seventeen and 20 LA/BR-PDAC patients were randomized to HTP-CT or CT. Baseline and CT-related features were balanced. At 6-months, 6-PFS rate was 41.2% and 30% in HTP-CT and CT arms (p = 0.48), respectively. A decrease ≥50% of serum CA19.9 was achieved in 75% and 64.3% of HTP-CT and CT patients (p = 0.53), respectively. TV reduced up to 6-months in 64.3% and 47.1% of HTP-CT and CT patients (p = 0.35), respectively. Resection rate, PFS-time and overall survival (OS-time) were similar. HTP-CT achieves a non-significant 11.2%, 10.7% and 17.2% improved 6-PFS, CA19.9 decrease ≥50% and TV reduction rates over CT, without any impact on resection rate, PFS-time and OS-time. As the study was underpowered, these results suggest further investigation of EUS-local ablation in selected patients with localized disease after induction CT.

27 April 2024 in Cancers
Verified
Journal Article
Open access
PDF file
CZCorinna Zimmermann
Corinna Zimmermann
AMAdrian Michelmann
Adrian Michelmann
YDYannick Daniel
Yannick Daniel
MEMarkus Enderle
Markus Enderle
Nermin SalkicNermin Salkic
Nermin Salkic
WLWalter Linzenbold
Walter Linzenbold
Background: The accurate delineation of ablation zones (AZs) is crucial for assessing radiofrequency ablation (RFA) therapy’s efficacy. Manual measurement, the current standard, is subject to variability and potential inaccuracies. Aim: This study aims to assess the effectiveness of Artificial Intelligence (AI) in automating AZ measurements in ultrasound images and compare its accuracy with manual measurements in ultrasound images. Methods: An in vitro study was conducted using chicken breast and liver samples subjected to bipolar RFA. Ultrasound images were captured every 15 s, with the AI model Mask2Former trained for AZ segmentation. The measurements were compared across all methods, focusing on short-axis (SA) metrics. Results: We performed 308 RFA procedures, generating 7275 ultrasound images across liver and chicken breast tissues. Manual and AI measurement comparisons for ablation zone diameters revealed no significant differences, with correlation coefficients exceeding 0.96 in both tissues (p < 0.001). Bland–Altman plots and a Deming regression analysis demonstrated a very close alignment between AI predictions and manual measurements, with the average difference between the two methods being −0.259 and −0.243 mm, for bovine liver and chicken breast tissue, respectively. Conclusion: The study validates the Mask2Former model as a promising tool for automating AZ measurement in RFA research, offering a significant step towards reducing manual measurement variability.

30 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JJJérémie Jacques
Jérémie Jacques
HNHorst Neuhaus
Horst Neuhaus
MEMarkus Enderle
Markus Enderle
UBUlrich Biber
Ulrich Biber
WLWalter Linzenbold
Walter Linzenbold
ARAlessandro Repici
Alessandro Repici
Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60–65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife® flex T-Type (HK-T) and the Olympus DualKnife® J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.

21 July 2023 in Cancers
Verified
Journal Article
Open access
PDF file
STSabrina Gloria Giulia Testoni
Sabrina Gloria Giulia Testoni
CMClaudia Minici
Claudia Minici
EBElisa Benetti
Elisa Benetti
FCFrancesca Clemente
Francesca Clemente
Daniela BoselliDaniela Boselli
Daniela Boselli
Emanuel Della TorreEmanuel Della Torre
Emanuel Della Torre
Immunological consequences of endoscopic ultrasound (EUS)-local thermal ablation (LTA) for pancreatic ductal adenocarcinoma (PDAC) have not been extensively assessed. We aimed to explore EUS-LTA effects on the systemic immune response in PDAC. Peripheral blood was collected from 10 treatment-naïve patients with borderline resectable and locally advanced PDAC, randomly allocated to Nab-paclitaxel plus Gemcitabine chemotherapy (CT-arm, n = 5) or EUS-LTA with HybridTherm Probe plus CT (HTP + CT-arm, n = 5). Twenty healthy donors were included as controls. Flow-cytometry and multiplex assays were used to profile immune cell subsets and measure serum cytokines/chemokines, respectively. At baseline, PDAC patients showed increased circulating monocytes and lower circulating lymphocytes and CD19+ B cells counts compared to healthy controls. After 4 months, CT induced decrease of B regulatory cells, CD4+ cytotoxic T cells and IL-1β. The addition of EUS-HTP to CT selectively decreased the serum levels of APRIL/TNFSF13 as well as T regulatory cells, total, classic and inflammatory monocytes. Serum levels of APRIL/TNFSF13 and total, classic and inflammatory monocytes counts at baseline were associated with worse overall survival. EUS-HTP has the potential to selectively impact on immune cells and cytokines associated with poor outcomes in PDAC.

Verified
Journal Article
Open access
PDF file
WLWalter Linzenbold
Walter Linzenbold
AFAndreas Fech
Andreas Fech
MHManuela Hofmann
Manuela Hofmann
Wilhelm AicherWilhelm Aicher
Wilhelm Aicher
MEMarkus Enderle
Markus Enderle
We noted recently that the injection of cells with a needle through a cystoscope in the urethral sphincter muscle of pigs failed to deposit them nearby or at the intended target position in about 50% of all animals investigated (n > 100). Increasing the chance for precise cell injection by shotgun approaches employing several circumferential injections into the sphincter muscle bears the risk of tissue injury. In this study, we developed and tested a novel needle-free technique to precisely inject cells in the urethral sphincter tissue, or other tissues, using a water-jet system. This system was designed to fit in the working channels of endoscopes and cystoscopes, allowing a wide range of minimally invasive applications. We analyze key features, including the physical parameters of the injector design, pressure ranges applicable for tissue penetration and cell injections and biochemical parameters, such as different compositions of injection media. Our results present settings that enable the high viability of cells post-injection. Lastly, the method is suitable to inject cells in the superficial tissue layer and in deeper layers, required when the submucosa or the sphincter muscle of the urethra is targeted.