Transition of the state of the boundary layer from laminar to turbulent plays an important role in the aerodynamic loss generation on turbine airfoils. An accurate simulation of the transition process and of the state of the boundary layer is therefore crucial for prediction of the aerodynamic efficiency of components in rotating machines. A lot of the research in the past years dealt with the transition over laminar separation bubbles, especially concerning flows in low pressure turbines (LPTs) of air jet engines. Nevertheless, bypass transition is also frequent in turbomachines at higher Reynolds numbers as well as for properly designed profiles. Compared with transition over a laminar separation bubble, a bypass transition is experimentally much more difficult to detect with standard measurement techniques. In such cases it becomes necessary to use more sophisticated techniques, such as hot-film anemometry, hot wires, or Preston probes in order to obtain accurate information on the state of the boundary layer. The study presented is carried out using a linear cascade with a LPT blade profile with strong front loading and gentle flow deceleration at the rear suction side of the blade. Measurements were performed at the high-speed cascade wind tunnel of the Institute of Jet Propulsion at engine relevant Mach and Reynolds numbers. Emphasis is put on the evaluation of the different transition processes at midspan and its influence on profile losses. The data postprocessing was adapted for compressible flows, which allows a more accurate determination of the transition area as well as qualitatively better distributions of the wall shear stress. Finally, comparisons with simulations, using computational fluid dynamics (CFD) tools, are performed and fields for improvement of the turbulence and transition models are identified.
Film cooling experiments were performed using a highly loaded high pressure turbine blade blade linear cascade. A large region with main flow separation is found on the pressure side and film cooling is provided into this area with three rows of either cylindrical or fan-shaped holes. The measurements comprise adiabatic film cooling effectiveness and profile static pressure measurements. The surface temperature was acquired with thermochromatic liquid crystals and using a hue to temperature correlation. The results shown are for variations in main flow Mach and Reynolds numbers at engine relevant levels and of coolant mass flows. The results for steady and periodic unsteady inflows with highly turbulent wakes created by cylindrical bars moving upstream in a plane parallel to the cascade are compared as two-dimensional surface plots, laterally averaged film cooling effectiveness and overall effectiveness over the entire surface.
AITEB-2 is a project where aerothermal challenges of modern high pressure turbine designs are analyzed. One of the scopes of the project is to allow for new gas turbine designs with less parts and lighter jet engines by increasing the blade pitch and therefore the aerodynamic blade loading. For transonic profiles, this leads to very high velocities on the suction side and shock induced separation is likely to occur. The total pressure loss increase due to flow separation and strong shocks, as well as the underturning of the flow, limits the increase of the blade pitch. In this paper, experiments using a linear turbine blade cascade with high aerodynamic loading are presented. The blade pitch is increased such that at design conditions, a strong separation occurs on the suction side. The experiments were run at high subsonic exit Mach numbers and at Reynolds numbers of 390,000 and 800,000. In order to reduce the flow separation and the aerodynamic losses, air jet vortex generators are used, which create streamwise vortices prior to the separation start. Since in high pressure turbine blades film cooling is widely used, also the influence of film cooling both with and without using vortex generators is analyzed. Film cooling is provided on the suction side by two rows of cylindrical holes. This paper provides an analysis of the influence of different main flow conditions, film cooling, and vortex generators on total pressure loss, heat transfer and film cooling effectiveness. The experiments show that the vortex generators, as well as the film cooling reduce flow separation and total pressure losses. The effects are also seen in the local heat transfer, especially with enhanced heat transport in the region with flow separation. The cases presented in this paper deal with complex flow phenomena, which are challenging to be predicted with modern numerical tools correctly. Therefore, the experimental data serve as a comprehensive database for validation of simulation tools in the AITEB-2 project.
Flow measurement using a linear compressor or turbine cascade is a well-established technique to characterize the flow in turbomachines with a certain degree of abstraction. A common way to obtain a general characterization of the flow is to measure the flow downstream of the cascade with a five-hole probe, obtaining, e.g., total pressure losses and flow turning. Pneumatic five-hole probes are used to capture steady or time-averaged flow quantities, if not specified otherwise. In dependency of probe geometry, measurement set-up and flow properties, such measurements can be very time-consuming. Various techniques, in order to decrease the measurement time, are proposed in literature but for certain applications the efforts required to implement such techniques can outweigh the enhanced measurement speed. In this paper, methods proposed by other authors are combined and extended to allow for fast or transient five-hole probe measurements at strongly varying flow conditions. The effectiveness of this method is presented for flow measurements downstream of a compressor cascade with attached and stalled flow (by varying the Reynolds number) as well as with steady and periodically unsteady inflow. The new method allows to reduce the measurement time by up to 90 percent without compromising measurement accuracy. In fact, due to higher spatial resolution, the flow downstream of the cascade can be better resolved with the new method.
Film cooling experiments were run at the high speed cascade wind tunnel of the University of the Federal Armed Forces Munich. The investigations were carried out with a linear cascade of highly loaded turbine blades. The main targets of the tests were to assess the film cooling effectiveness and the heat transfer in zones with main flow separation. Therefore the blades were designed to force the flow to detach on the pressure side shortly downstream of the leading edge and it reattaches at about half of the axial chord. In this zone, film cooling rows are placed among others for reduction of the size of the separation bubble. The analyzed region on the blade is critical due to the high heat transfer present at the leading edge and at the reattachment line after main flow separation. Film cooling can contribute to a reduction of the size of the separation bubble reducing aerodynamic losses but increases in general heat transfer due to turbulent mixing. The reduction of the size of the separation bubble might also be two-fold since it acts like a thermal insulator on the blade and reducing the size of the bubble might lead to stronger heating of the blade. Film cooling should therefore take into account both: firstly, a proper protection of the surface, and secondly, reduce aerodynamic losses diminishing the extension of the main flow separation. The overall effectiveness of film cooling for a real engine has to combine heat transfer with film cooling effect. In this paper, the overall effectiveness of film cooling, combining results from measurements of the adiabatic film cooling effectiveness and the local heat transfer coefficient are shown. The tests comprise the analysis of the effect of different outlet Mach and Reynolds numbers at engine relevant values and film cooling ratio. A new parameter is introduced which allows for the evaluation of the effect of film cooling accounting at the same time for the change of local heat transfer coefficient. To the authors’ opinion this parameter allows a better, physically based assessment than the strategy using the so-called heat flux ratio. A parameter study is carried out in order to benchmark the effect of changes of the blade design.
Film cooling experiments were run at the high speed cascade wind tunnel of the University of the Federal Armed Forces Munich. The investigations were carried out with a linear cascade of highly loaded turbine blades. The main objectives of the tests were to assess the film cooling effectiveness and the heat transfer in zones with main flow separation. Therefore, the blades were designed to force the flow to detach on the pressure side shortly downstream of the leading edge and reattach at about half of the axial chord. In this zone, film cooling rows are placed among others for a reduction of the size of the separation bubble. The analyzed region on the blade is critical due to the high heat transfer present at the leading edge and at the reattachment line after the main flow separation. Film cooling can contribute to a reduction of the size of the separation bubble reducing aerodynamic losses, however, in general, it increases heat transfer due to turbulent mixing. The reduction of the size of the separation bubble might also be twofold, since it acts like a thermal insulator on the blade and reducing the size of the bubble might lead to a stronger heating of the blade. Film cooling should, therefore, take both into account: first, a proper protection of the surface and second, reducing aerodynamic losses, diminishing the extension of the main flow separation. While experimental results of the adiabatic film cooling effectiveness were shown in previous publications, the local heat transfer is analyzed in this paper. Emphasis is also placed upon analyzing, in detail, the flow separation process. Furthermore, the tests comprise the analysis of the effect of different outlet Mach and Reynolds numbers and film cooling. In part two of this paper, the overall film cooling effectiveness is addressed. Local heat transfer is still difficult to predict with modern numerical tools and this is especially true for complex flows with flow separation. Some numerical results with the Reynolds averaged Navier-Stokes (RANS) and large eddy simulation (LES) show the capability of a commercial solver in predicting the heat transfer.