Thomas Gervais

Prof. Thomas Gervais

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2019 in Nature
Verified
Journal Article
Closed access
PDF file
OGOnur Gökçe
Onur Gökçe
SCSamuel Castonguay
Samuel Castonguay
YTYuksel Temiz
Yuksel Temiz
TGThomas Gervais
Thomas Gervais
EDEmmanuel Delamarche
Emmanuel Delamarche

27 November 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MMM. Marimuthu
M. Marimuthu
NRNassim Rousset
Nassim Rousset
ASAmélie St-Georges-Robillard
Amélie St-Georges-Robillard
MLM. A. Lateef
M. A. Lateef
MFM. Ferland
M. Ferland
TGThomas Gervais
Thomas Gervais
We present a microfluidic platform for automatic multi-size spheroid formation within constant volume hanging droplets (HDs) from a single inlet loading of a constant cell concentration.

20 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ABAyoola Brimmo
Ayoola Brimmo
PGPierre-Alexandre Goyette
Pierre-Alexandre Goyette
RARoaa Alnemari
Roaa Alnemari
TGThomas Gervais
Thomas Gervais
Mohammad QasaimehMohammad Qasaimeh
Mohammad Qasaimeh
In this work, we fabricate microfluidic probes (MFPs) in a single step by stereolithographic 3D printing and benchmark their performance with standard MFPs fabricated via glass or silicon micromachining. Two research teams join forces to introduce two independent designs and fabrication protocols, using different equipment. Both strategies adopted are inexpensive and simple (they only require a stereolithography printer) and are highly customizable. Flow characterization is performed by reproducing previously published microfluidic dipolar and microfluidic quadrupolar reagent delivery profiles which are compared to the expected results from numerical simulations and scaling laws. Results show that, for most MFP applications, printer resolution artifacts have negligible impact on probe operation, reagent pattern formation, and cell staining results. Thus, any research group with a moderate resolution (≤100 µm) stereolithography printer will be able to fabricate the MFPs and use them for processing cells, or generating microfluidic concentration gradients. MFP fabrication involved glass and/or silicon micromachining, or polymer micromolding, in every previously published article on the topic. We therefore believe that 3D printed MFPs is poised to democratize this technology. We contribute to initiate this trend by making our CAD files available for the readers to test our “print & probe” approach using their own stereolithographic 3D printers.

16 April 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
PGPierre-Alexandre Goyette
Pierre-Alexandre Goyette
ÉBÉtienne Boulais
Étienne Boulais
FNFrédéric Normandeau
Frédéric Normandeau
GLGabriel Laberge
Gabriel Laberge
DJDavid Juncker
David Juncker
TGThomas Gervais
Thomas Gervais
Microfluidic multipoles (MFMs) have been realized experimentally and hold promise for “open-space” biological and chemical surface processing. Whereas convective flow can readily be predicted using hydraulic-electrical analogies, the design of advanced microfluidic multipole is constrained by the lack of simple, accurate models to predict mass transport within them. In this work, we introduce the complete solutions to mass transport in multipolar microfluidics based on the iterative conformal mapping of 2D advection-diffusion around a simple edge into dipoles and multipolar geometries, revealing a rich landscape of transport modes. The models are validated experimentally with a library of 3D printed devices and found in excellent agreement. Following a theory-guided design approach, we further ideate and fabricate two classes of spatiotemporally reconfigurable multipolar devices that are used for processing surfaces with time-varying reagent streams, and to realize a multistep automated immunoassay. Overall, the results set the foundations for exploring, developing, and applying open-space microfluidic multipoles.

21 August 2021 in Cancers
Verified
Journal Article
Open access
PDF file
DDDina Dorrigiv
Dina Dorrigiv
KSKayla Simeone
Kayla Simeone
LCLaudine Communal
Laudine Communal
JKJennifer Kendall-Dupont
Jennifer Kendall-Dupont
ASAmélie St-Georges-Robillard
Amélie St-Georges-Robillard
TGThomas Gervais
Thomas Gervais
Predicting patient responses to anticancer drugs is a major challenge both at the drug development stage and during cancer treatment. Tumor explant culture platforms (TECPs) preserve the native tissue architecture and are well-suited for drug response assays. However, tissue longevity in these models is relatively low. Several methodologies have been developed to address this issue, although no study has compared their efficacy in a controlled fashion. We investigated the effect of two variables in TECPs, specifically, the tissue size and culture vessel on tissue survival using micro-dissected tumor tissue (MDT) and tissue slices which were cultured in microfluidic chips and plastic well plates. Tumor models were produced from ovarian and prostate cancer cell line xenografts and were matched in terms of the specimen, total volume of tissue, and respective volume of medium in each culture system. We examined morphology, viability, and hypoxia in the various tumor models. Our observations suggest that the viability and proliferative capacity of MDTs were not affected during the time course of the experiments. In contrast, tissue slices had reduced proliferation and showed increased cell death and hypoxia under both culture conditions. Tissue slices cultured in microfluidic devices had a lower degree of hypoxia compared to those in 96-well plates. Globally, our results show that tissue slices have lower survival rates compared to MDTs due to inherent diffusion limitations, and that microfluidic devices may decrease hypoxia in tumor models.

21 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NRNassim Rousset
Nassim Rousset
FMFrédéric Monet
Frédéric Monet
TGThomas Gervais
Thomas Gervais
This work focuses on modelling design and operation of “microfluidic sample traps” (MSTs). MSTs regroup a widely used class of microdevices that incorporate wells, recesses or chambers adjacent to a channel to individually trap, culture and/or release submicroliter 3D tissue samples ranging from simple cell aggregates and spheroids, toex vivotissue samples and other submillimetre-scale tissue models. Numerous MST designs employing various trapping mechanisms have been proposed in the literature, spurring the development of 3D tissue models for drug discovery and personalized medicine. Yet, there lacks a general framework to optimize trapping stability, trapping time, shear stress, and sample metabolism. Herein, the effects of hydrodynamics and diffusion-reaction on tissue viability and device operation are investigated using analytical and finite element methods with systematic parametric sweeps over independent design variables chosen to correspond to the four design degrees of freedom. Combining different results, we show that, for a spherical tissue of diameterd < 500 μm, the simplest, closest to optimal trap shape is a cube of dimensionsw equal to twice the tissue diameter:w = 2d. Furthermore, to sustain tissues without perfusion, available medium volume per trap needs to be 100× the tissue volume to ensure optimal metabolism for at least 24 hours.