Nassim Rousset

Dr. Nassim Rousset


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MAM. Astolfi
M. Astolfi
BPB. Péant
B. Péant
MLM. A. Lateef
M. A. Lateef
NRNassim Rousset
Nassim Rousset
JKJ. Kendall-Dupont
J. Kendall-Dupont
TGT. Gervais
T. Gervais
Micro-dissected tumor tissues (MDTs) are maintained alive on chip for several days and show promising results for personalized medicine applications.

29 January 2020 in Advanced Biosystems
Verified
Journal Article
Closed access
PDF file
PMPatrick M. Misun
Patrick M. Misun
BYBurcak Yesildag
Burcak Yesildag
FFFelix Forschler
Felix Forschler
ANAparna Neelakandhan
Aparna Neelakandhan
NRNassim Rousset
Nassim Rousset
OFOlivier Frey
Olivier Frey

27 November 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MMM. Marimuthu
M. Marimuthu
NRNassim Rousset
Nassim Rousset
ASAmélie St-Georges-Robillard
Amélie St-Georges-Robillard
MLM. A. Lateef
M. A. Lateef
MFM. Ferland
M. Ferland
TGThomas Gervais
Thomas Gervais
We present a microfluidic platform for automatic multi-size spheroid formation within constant volume hanging droplets (HDs) from a single inlet loading of a constant cell concentration.

1 February 2019 in SLAS Technology
Verified
Journal Article
Open access
PDF file
CLChristian Lohasz
Christian Lohasz
NRNassim Rousset
Nassim Rousset
KRKasper Renggli
Kasper Renggli
AHAndreas Hierlemann
Andreas Hierlemann
OFOlivier Frey
Olivier Frey
Microphysiological systems hold the promise to increase the predictive and translational power of in vitro substance testing owing to their faithful recapitulation of human physiology. However, the implementation of academic developments in industrial settings remains challenging. We present an injection-molded microfluidic microtissue (MT) culture chip that features two channels with 10 MT compartments each and that was designed in compliance with microtiter plate standard formats. Polystyrene as a chip material enables reliable, large-scale production and precise control over experimental conditions due to low adsorption or absorption of small, hydrophobic molecules at or into the plastic material in comparison with predecessor chips made of polydimethylsiloxane. The chip is operated by tilting, which actuates gravity-driven flow between reservoirs at both ends of every channel, so that the system does not require external tubing or pumps. The flow rate can be modulated by adjusting the tilting angle on demand. The top-open design of the MT compartment enables efficient MT loading using standard or advanced pipetting equipment, ensures oxygen availability in the chip, and allows for high-resolution imaging. Every channel can be loaded with up to 10 identical or different MTs, as demonstrated by culturing liver and tumor MTs in the same medium channel on the chip.

21 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NRNassim Rousset
Nassim Rousset
FMFrédéric Monet
Frédéric Monet
TGThomas Gervais
Thomas Gervais
This work focuses on modelling design and operation of “microfluidic sample traps” (MSTs). MSTs regroup a widely used class of microdevices that incorporate wells, recesses or chambers adjacent to a channel to individually trap, culture and/or release submicroliter 3D tissue samples ranging from simple cell aggregates and spheroids, toex vivotissue samples and other submillimetre-scale tissue models. Numerous MST designs employing various trapping mechanisms have been proposed in the literature, spurring the development of 3D tissue models for drug discovery and personalized medicine. Yet, there lacks a general framework to optimize trapping stability, trapping time, shear stress, and sample metabolism. Herein, the effects of hydrodynamics and diffusion-reaction on tissue viability and device operation are investigated using analytical and finite element methods with systematic parametric sweeps over independent design variables chosen to correspond to the four design degrees of freedom. Combining different results, we show that, for a spherical tissue of diameterd < 500 μm, the simplest, closest to optimal trap shape is a cube of dimensionsw equal to twice the tissue diameter:w = 2d. Furthermore, to sustain tissues without perfusion, available medium volume per trap needs to be 100× the tissue volume to ensure optimal metabolism for at least 24 hours.

1 February 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
NRNassim Rousset
Nassim Rousset
RSRubén López Sandoval
Rubén López Sandoval
MMMario Matteo Modena
Mario Matteo Modena
AHAndreas Hierlemann
Andreas Hierlemann
PMPatrick M. Misun
Patrick M. Misun
As 3D in vitro tissue models become more pervasive, their built-in nutrient, metabolite, compound, and waste gradients increase biological relevance at the cost of analysis simplicity. Investigating these gradients and the resulting metabolic heterogeneity requires invasive and time-consuming methods. An alternative is using electrochemical biosensors and measuring concentrations around the tissue model to obtain size-dependent metabolism data. With our hanging-drop-integrated enzymatic glucose biosensors, we conducted current measurements within hanging-drop compartments hosting spheroids formed from the human colorectal carcinoma cell line HCT116. We developed a physics-based mathematical model of analyte consumption and transport, considering (1) diffusion and enzymatic conversion of glucose to form hydrogen peroxide (H2O2) by the glucose-oxidase-based hydrogel functionalization of our biosensors at the microscale; (2) H2O2 oxidation at the electrode surface, leading to amperometric H2O2 readout; (3) glucose diffusion and glucose consumption by cancer cells in a spherical tissue model at the microscale; (4) glucose and H2O2 transport in our hanging-drop compartments at the macroscale; and (5) solvent evaporation, leading to glucose and H2O2 upconcentration. Our model relates the measured currents to the glucose concentrations generating the currents. The low limit of detection of our biosensors (0.4 ± 0.1 μM), combined with our current-fitting method, enabled us to reveal glucose dynamics within our system. By measuring glucose dynamics in hanging-drop compartments populated by cancer spheroids of various sizes, we could infer glucose distributions within the spheroid, which will help translate in vitro 3D tissue model results to in vivo.