Ievgen Levadnyi

Dr. Ievgen Levadnyi


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
ILIevgen Levadnyi
Ievgen Levadnyi
Jan AwrejcewiczJan Awrejcewicz
Jan Awrejcewicz
YZYan Zhang
Yan Zhang
MGMárcio Fagundes Goethel
Márcio Fagundes Goethel
YGYaodong Gu
Yaodong Gu
This study investigated the influence of human head impact on the severity of traumatic brain injury. Simulation of the dynamic impact of a human head was performed using FEM (finite element method) and employing HIC (Head Injury Criterion). The study of traumatic brain injury included impacts with the occiput, temporal, forehead, and parietal part of the head, and the impact velocity at the surface ranged from 1 to 7 m/s. The following characteristics were considered and analyzed in the simulation: duration of the impact, intracranial pressure, HIC, and change in accelerations at the center of gravity of the brain. The computed distribution of pressure values in the brain during an impact confirmed the theory of inertial intracranial brain displacement. The effect of a protective helmet aimed at reducing the severity of traumatic brain injury was investigated, and a method to determine rational helmet parameters was developed. In the case of the protected head, impact acceleration occurred over a longer period of time, which yielded a reduction in the brain load compared to the unprotected head. The developed method allows us to predict the severity of traumatic brain injury (TBI) in the protected/unprotected human head and to provide recommendations for the determination of rational parameters for manufacturing personal protective equipment for the head.

8 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
FFFu Fengqin
Fu Fengqin
ILIevgen Levadnyi
Ievgen Levadnyi
JWJiayu Wang
Jiayu Wang
ZXZhihao Xie
Zhihao Xie
Gusztáv FeketeGusztáv Fekete
Gusztáv Fekete
Yaodong GuYaodong Gu
Yaodong Gu
In this paper, to investigate the independent effect of the construction of the forefoot carbon-fiber plate inserted to the midsole on running biomechanics and finite element simulation, fifteen male marathon runners were arranged to run across a runway with embedded force plates at two specific running speeds (fast-speed: 4.81 ± 0.32 m/s, slow-speed: 3.97 ± 0.19 m/s) with two different experimental shoes (a segmented forefoot plate construction (SFC), and a full forefoot plate construction (FFC)), simulating the different pressure distributions, energy return, and stiffness during bending in the forefoot region between the SFC and FFC inserted to midsole. Kinetics and joint mechanics were analyzed. The results showed that the footwear with SFC significantly increased the peak metatarsophalangeal joint (MTPJ) plantarflexion velocity and positive work at the knee joint compared to the footwear with FFC. The results about finite element simulation showed a reduced maximum pressure on the midsole; meanwhile, not significantly affected was the longitudinal bending stiffness and energy return with the SFC compared to the FFC. The results can be used for the design of marathon running shoes, because changing the full carbon fiber plate to segment carbon fiber plate induced some biomechanical transformation but did not significantly affect the running performance, what is more, reducing the peak pressure of the carbon plate to the midsole by cutting the forefoot area of the carbon fiber plate could be beneficial from a long-distance running perspective for manufacturers.

26 September 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
SSSergey Strafun
Sergey Strafun
ILIevgen Levadnyi
Ievgen Levadnyi
VMVasily Makarov
Vasily Makarov
Jan AwrejcewiczJan Awrejcewicz
Jan Awrejcewicz
Radial head fractures are becoming a major public health problem and are an increasingly important target for both clinical and mechanical researchers. In this work, comparative biomechanical analyses of the stress–strain state of a healthy elbow joint and elbow joints with radial head compression from 2 to 5 mm due to injury are performed. Three-dimensional models of the elbow joint with cartilage surfaces and ligaments were constructed based on the results of computed tomography. This study is focused on an elbow joint range of motion ranging from 0° to 120° flexion. Analysis of the stress–strain state of cartilage and ligaments under the influence of functional loads is conducted using a finite element method (FEM) and the ABAQUS software package. The results show that with increasing compression of the radial head, contact stress increases at the olecranon, which can lead to cartilage damage. Analysis of displacement shows that compression of the radial head during full extension of the elbow joint leads to an increased humeral shift from 1.14° ± 0.22 in the healthy joint to 10.3° ± 2.13 during 5-mm compression of the radial head. Mathematical modeling performed in this study proved that reducing the height of the radial head and the contact area between the radial head and the humeral head led to increased medial collateral ligament stresses of up to 36 ± 3.8 MPa. This work confirmed that the head of the radius is the main stabilizing structure of the elbow joint and that the medial collateral ligament is the second structure responsible for valgus stability of the elbow joint.

1 April 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
ILIevgen Levadnyi
Ievgen Levadnyi
FLFujia Liu
Fujia Liu
YGYaodong Gu
Yaodong Gu
Material models play a crucial role in finite element analysis, especially for evaluating deformations under high strain rates. This study introduces a straightforward method that combines experiments, numerical simulations, and optimization to identify the parameters of a ductile material model at high strain rates. We conduct ballistic impact tests using a single-stage light gas gun and spherical projectiles on Q235 steel at velocities ranging from 160 to 476 m/s to determine its properties. An iterative inverse finite element analysis helps to refine the Johnson–Cook material model constants, aligning them with the observed crater dimensions on the specimens caused by impacts at various speeds. The model’s predictions for the crater profiles show a good match with the experimental findings across all tested velocities. Simulation outcomes reveal high strain values up to 3.81 and strain rates reaching 41 872 s−1. Moreover, we assess the model’s failure behavior under high strain rates through both perforation resistance tests and simulations on Q235 steel plates of varying thicknesses under ballistic impacts. The successful validation of the Johnson–Cook model for Q235 steel at these rates confirms the efficacy and reliability of our characterization method. This approach can be applied to develop model parameters for different materials under similar strain conditions.

18 August 2020 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
ILIevgen Levadnyi
Ievgen Levadnyi
JAJan Awrejcewicz
Jan Awrejcewicz
YZYan Zhang
Yan Zhang
YGYaodong Gu
Yaodong Gu
Bone fracture, formation and adaptation are related to mechanical strains in bone. Assessing bone stiffness and strain distribution under different loading conditions may help predict diseases and improve surgical results by determining the best conditions for long-term functioning of bone-implant systems. In this study, an experimentally wide range of loading conditions (56) was used to cover the directional range spanned by the hip joint force. Loads for different stance configurations were applied to composite femurs and assessed in a material testing machine. The experimental analysis provides a better understanding of the influence of the bone inclination angle in the frontal and sagittal planes on strain distribution and stiffness. The results show that the surface strain magnitude and stiffness vary significantly under different loading conditions. For the axial compression, maximal bending is observed at the mid-shaft, and bone stiffness is also maximal. The increased inclination leads to decreased stiffness and increased magnitude of maximum strain at the distal end of the femur. For comparative analysis of results, a three-dimensional, finite element model of the femur was used. To validate the finite element model, strain gauges and digital image correlation system were employed. During validation of the model, regression analysis indicated robust agreement between the measured and predicted strains, with high correlation coefficient and low root-mean-square error of the estimate. The results of stiffnesses obtained from multi-loading conditions experiments were qualitatively compared with results obtained from a finite element analysis of the validated model of femur with the same multi-loading conditions. When the obtained numerical results are qualitatively compared with experimental ones, similarities can be noted. The developed finite element model of femur may be used as a promising tool to estimate proximal femur strength and identify the best conditions for long-term functioning of the bone-implant system in future study.

15 October 2017 in Journal of Theoretical and Applied Mechanics
Verified
Journal Article
Open access
PDF file
ILIevgen Levadnyi
Ievgen Levadnyi
Jan AwrejcewiczJan Awrejcewicz
Jan Awrejcewicz
ALAlexander Loskutov
Alexander Loskutov
OSOlga Szymanowska
Olga Szymanowska
Recommendations for the optimal thickness of the cement mantle in cemented hip arthroplasty are outlined based on the results obtained with the finite element method. The investigations show that distal femur cement thickness higher than 2mm positively affects mechanical behaviour of the cement mantle and can be useful in reducing stress-strain levels in the distal part of the femur what leads to prevention of development of a stress-shielding effect. The results of the study can contribute to the success of long-term implants.