This paper explores automatic generation control (AGC) of a more realistic 2-area multi-source power system comprising hydro, thermal, gas, and wind energy sources-based power plants in each control area. The wind power plants (WPPs) have been growing continuously worldwide due to their inherent feature of providing eco-friendly sustainable energy. But, operations of WPPs are associated with system stability problems due to lack of inertia. However, WPPs do not participate in the elimination of mismatch between generation and demand by AGC but disturbance can be injected by the WPPs due to the stochastic nature of wind energy. An optimal controller based on full state feedback control theory is designed to conduct the study. The system dynamic performance analysis is carried out for 1% step load disturbance in corresponding control areas. It is observed that the system dynamic graphs of deviation in area frequency and tie-line power are significantly improved with the implementation of optimal AGC controller compared to GA tuned classical controller. It has also been shown that the WPPs aid the increase in load disturbance when the input wind power reduces but it negates the effect of increase in load disturbance for increase in wind energy to the WPPs.
1 April 2021 in Engineering Science and Technology, an International Journal
This paper presents the accurate modeling of HVDC links for the dynamic studies of automatic generation control/load frequency control (AGC/LFC) of multi-area interconnected power system. In earlier AGC studies, HVDC links were simply modeled by using the first-order transfer function with system time constant T_dc. It was argued that T_dc is the time required by HVDC links to establish DC current after following a load disturbance in power system. However, no mathematical or analytical justification was provided in support to the existing transfer function model of HVDC links. This paper presents the accurate modeling of HVDC links for AGC studies. The comparative analysis has also been performed to demonstrate error being accrued due to the use of conventional model of HVDC links. Furthermore, this paper also implements the inertia emulation based control (INEC) strategy in AGC which allows to harness the stored energy from the capacitance of HVDC links for AGC operations.
21 June 2021 in International Journal of Modelling and Simulation
This paper reviews the existing models, connection schemes and maximum power point tracking (MPPT) methods of PV arrays. The partial shading causes significant power losses. It is very difficult to maintain uniform irradiance over the entire PV array, especially for rooftop or building-integrated PV systems. The aspects such as connection scheme of PV array, shading pattern and maximum power point tracking (MPPT) techniques, etc., decide the power generated by the PV array. The conventional MPPT methods are only capable of reaching maximum power point (MPP) in identical insolation situations. Hence, conventional MPP tracking becomes inept due to the existence of several peaks in the P-V characteristics. There are different global maximum power point (GMPP) tracking techniques available in the literature that operate in partial shading scenarios. The reconfiguration of the PV array reduces the number of multiple peaks. This reduction in several peaks makes conventional MPP tracking techniques competent even under partial shading conditions with low implementation complexity and higher tracking speed. This paper can assist scientists in choosing a precise objective-based PV module model, connection schemes and MPP tracking methods out of numerous schemes available in the literature.