The utilization of Concrete-filled steel Tubular (CFST) columns is increasingly widespread. However, the assessment of the residual bearing capacity of CFST columns currently relies mainly on costly and time-consuming experiments and numerical simulations. In this study, we propose a machine learning-based model for rapidly identifying the residual bearing capacity of CFST columns. The results demonstrate that the predictions of the proposed Stacking-KRXL model align well with the actual values, with most prediction errors falling within ±10%. The RSquared value of 0.97 significantly surpasses that of other methods. The stability and robustness of the model are analyzed. Additionally, the Shapley additive explanations method is applied for global and local interpretations, revealing positive or negative correlations between different parameters and the residual bearing capacity of CFST columns, mainly influenced by the concrete area in the core region.
Reinforced concrete (RC) walls are extensively used in civil air defense engineering and are susceptible to low-speed impacts with high energy and massive weight during service. Therefore, it is crucial to consider the impact resistance of these walls and explore effective protection methods. The honeycomb structure, known for its energy-absorbing properties, has been widely utilized in aerospace, automotive, and maritime industries. However, there is a need for more research on applying honeycomb structures in energy-absorbing protection devices in civil engineering. This study proposes the use of honeycomb sandwich panels to protect civil air defense RC walls, creating a Honeycomb Sandwich Panel Composite RC wall (HSP-RC wall). Through pendulum impact experiments, we investigated the dynamic response of RC walls, both standard and HSP-RC walls with varying honeycomb parameters, under high-energy impacts. The goal was to evaluate the impact resistance of these RC walls, analyze the deformation differences among different HSP-RC walls, and examine the influence of honeycomb parameters on the impact protection effectiveness. The research results indicate that honeycomb sandwich panels can provide impact protection for RC walls by absorbing energy, and their protection effect is related to the parameters of the honeycomb core layer. This research result can be applied to RC structures that bear impact loads, achieving effective protection for RC structures.
Prefabricated assembly structures play a pivotal role in modern building construction and underground transit developments, offering benefits such as ease of installation, rapid construction, and environmental sustainability. These prefabricated assembly structures are always symmetric and particularly prevalent in projects like subway station construction, where symmetry prefabricated blocks are commonly used. The hoisting and overturning of these blocks are crucial stages in the construction sequence. Given the substantial weight (tens of tons) and size (several meters) of these prefabricated elements, the materials and structural integrity of the metal components, including bolts and steel rods, must meet strict standards during these phases. To ensure stability during overturning and safety throughout hoisting, this paper utilizes a finite element model to analyze the hoisting and overturning of three prefabricated blocks used in subway station assembly. This paper investigates the mechanical behavior of embedded components, such as lifting lugs, steel liners, and hoisting steel rods, during these processes, analyzing their stress and strain. The selection methods of different steel bars (diameter, hollow, solid, etc.) in the hoisting process were obtained, and the operation speed in the hoisting and overturning process was determined, which guided the selection of the hoisting position when the common overturning action was known. The results offer valuable guidelines for the placement and spacing of lifting lugs, as well as the optimal hoisting speed, thereby informing the selection of embedded lifting lugs and the design of operational protocols in actual assembly construction.
Reinforced concrete walls (RC walls) are widely used in transportation, building structures, and civil air defence engineering. RC walls are vulnerable to low-velocity impact, such as the fall of components caused by earthquakes or explosions, for example, and the impact from road objects, such as vehicles, during their service life. When subjected to instantaneous high-energy impact, RC walls at key positions are prone to severe damage, which can further lead to structural collapse. Therefore, it is necessary to consider improving the impact resistance of key RC walls in a structure. Using a porous honeycomb structure with excellent energy absorption performance to provide impact protection for key RC walls is an effective way to reduce the damage of RC walls and thereby enhance the impact resistance of a structure. Therefore, based on the author’s previous series of experimental and numerical studies on the impact resistance of RC walls, as well as the high-mass pendulum impact experimental study on the honeycomb sandwich panel composite RC wall (HSP-RC wall), this paper adopts a multi-scale modelling method in micro-mechanics and macro-mechanics to establish a pendulum impact finite element model (FEM) for the HSP-RC wall. The representative volume element (RVE) and periodic boundary condition (PBC) are used to calculate the elastic property parameters of the honeycomb, which guide the establishment of the FEMs for the HSP-RC wall. The FEMs can avoid the computational difficulty caused by refined simulation, analyse the impact damage of the HSP-RC walls more accurately, quantify the impact protection effect of the honeycomb sandwich panel, and thus facilitate the parametric analysis of the impact resistance of HSP-RC walls with different honeycomb panel structural parameters in subsequent studies.
Three-dimensional braided composites have become one kind of critical engineering material for applications in extreme environments. The 3D stepwise rotary braiding process is one vital technique for manufacturing preforms with high efficiency and flexibility. However, the fabric topology is decided by the combination of switch rotation directions, which affects the mechanical properties, and the full carrier configuration results in a loose four-directional structure which is supposed to be improved by adding axial yarns. Therefore, experiments are carried out to illustrate the effect of fabric topology and axial yarn condition on the compressive properties of 3D stepwise rotary braided composites. Samples with three types of fabric topologies named Type A, B, and C are prepared under four axial yarn conditions including no axial yarn addition, 12K axial yarn addition, 24K axial yarn addition, and 36K axial yarn addition, which are fabricated with braiding angles of 20°, 30° and 40°. Longitudinal and transverse compression tests are conducted, and the morphology is observed. It shows that the braiding angle has more influence on the longitudinal compressive properties than transverse compressive properties, and the effect of fabric topology and axial yarn condition depends on the braiding angle. The fabric topology affects a lot on the longitudinal compressive properties when the braiding angle is small, resulting in a gap of up to 40%. The longitudinal compressive properties are improved significantly by adding axial yarns especially for the composites with large braiding angles, making the strength more than double. With the increase in axial yarn size, the strength increment gradually decreases while the modulus declines after a certain size for smaller braiding angles.