The thread shape factor (TSF) to evaluate the relationships between geometrical characteristics and mechanical properties of the temporary anchorage devices (TADs) has recently been introduced. This in vitro experimental study evaluated in 30 different tests with three TADs: ORTHOImplant (1.8 mm diameter and 10 mm length; 3M Unitek), Tomas (1.6 mm diameter and 10 mm length; Dentaurum), and Orthoeasy (1.7 mm diameter and 10 mm length; Forestadent). Scanning electron microscopy images were acquired for each TAD to measure the TSF; afterwards, the maximum insertion torque (MIT) was evaluated and thereafter pull-out tests on two differently designed organic bone analogs were carried out using a testing machine with a crosshead speed of 2 mm/minute being applied. One-way analysis of variance with group as factor was performed. Post hoc multiple comparisons Bonferroni test was used. Rank-transformed data were used when asymmetry of data was shown. To assess correlation between characteristics, load, and MIT, Spearman’s rank correlation coefficient was used. A P-value of 0.05 was considered statistically significant. Significant direct correlations were found between TSF and depth and both load and MIT. Particularly, a correlation of 0.90 (P < 0.001) was found between depth and MIT for 2.2 mm cortical thickness. The authors conclude that MIT and maximum load values of pull-out test are statistically related to depth of the thread of the screw and to TSF.
8 April 2024 in The Korean Journal of Orthodontics
Marco Migliorati, Sara Drago, Tommaso Castroflorio, Paolo Pesce, Giovanni Battista, Alessandra Campobasso, Giorgio Gastaldi, Filippo Forin Valvecchi, Anna De Mari. Korean J Orthod 2024;54:160-70. https://doi.org/10.4041/kjod23.268
24 February 2022 in European Journal of Orthodontics
Summary: Objectives: This retrospective CBCT study aimed to evaluate the palatal anatomical characteristics using the third palatal ruga as a reliable clinical reference for miniscrew placement. Methods: Thirty-six subjects (mean age17.1 y.o. ± 4.1) were randomly selected and their records (CBCT volume and maxillary digital models) were included. BlueSkyPlan CBCT software viewer (BluSkyBio, V4.7) was used to measure the following outcomes at the level of third palatal ruga, 2 mm anteriorly and 2 mm posteriorly: total bone depth, cortical bone thickness, and mucosa thickness. The outcomes were evaluated on lines perpendicular to the palatal mucosa laying on different sagittal planes: the mid-palatal plane, 2 and 4 mm paramedian planes. Results: The maximum mean amount of bone depth was registered 2 mm posteriorly to the third ruga and 4 mm paramedian (9.7 mm). No significant difference was observed between the third ruga insertion site and its corresponding 2 mm posterior site. Cortical bone of palatal vault did not change significantly in anteroposterior direction for all the considered sites. Significant differences were found comparing cortical bone at the suture level with cortical bone 2-mm and 4-mm paramedian at all anteroposterior levels. Palatal mucosa increases its thickness in paramedian insertion sites, and it decreases in posterior insertion sites. Conclusions: Both third palatal ruga and 2 mm posteriorly to third ruga (4 mm paramedian) could be the optimal insertion site for palatal miniscrew placement, depending on individual anatomic conditions. The thickness of the cortical palatal bone showed, at 4 mm paramedian, optimal characteristics for miniscrew primary stability. Palatal mucosa thickness values suggest miniscrew neck extension of 2.0–2.5 mm for optimal mucosa adaptation.