Riccardo Nucera

Prof. Riccardo Nucera

University of Messina, Messina, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
CDCarolina Dolci
Carolina Dolci
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
SCStefania Costa
Stefania Costa
SBSerena Barbera
Serena Barbera
Marco PortelliMarco Portelli
Marco Portelli
This systematic review aims to highlight the differences between different clear aligner therapies that differ in the presence of attachments or in attachment configuration. Eight electronic databases were searched up to March 2020. Two authors independently proceeded to study selection, data extraction, and risk of bias assessment. The analysis of the results was carried out examining six groups of movements (mesio-distal tipping/bodily movement; anterior bucco-lingual tipping/root torque; posterior bucco-lingual tipping/expansion; intrusion; extrusion; rotation). Five clinical trials were selected and all of them showed a medium risk of bias. Literature showed that attachments mostly increase the effectiveness of orthodontic treatment with clear aligners, improving anterior root torque, rotation, and mesio-distal (M-D) movement; they are also important to increase posterior anchorage. However, some articles showed contradictory or not statistically significant results. Attachments also seem to improve intrusion, but the evidence about this movement, as well as extrusion, is lacking. No studies evaluated posterior bucco-lingual tipping/expansion. Further clinical trials are strongly suggested to clarify the influence of attachments and their number, size, shape, and position on each orthodontic movement.

14 April 2014 in Orthodontics & Craniofacial Research
Verified
Journal Article
Closed access
PDF file
GCG. Cordasco
G. Cordasco
GMG. Matarese
G. Matarese
Lorenzo RusticoLorenzo Rustico
Lorenzo Rustico
SFS. Fastuca
S. Fastuca
Alberto CaprioglioAlberto Caprioglio
Alberto Caprioglio
Riccardo NuceraRiccardo Nucera
Riccardo Nucera

1 September 2017 in The Angle Orthodontist
Verified
Journal Article
Closed access
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Antonino Lo GiudiceAntonino Lo Giudice
Antonino Lo Giudice
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
PSPaola Spinuzza
Paola Spinuzza
ACAlberto Caprioglio
Alberto Caprioglio
GCGiancarlo Cordasco
Giancarlo Cordasco
Objective: To analyze the buccal bone thickness, bone depth, and cortical bone depth of the mandibular buccal shelf (MBS) to determine the most suitable sites of the MBS for mini-screw insertion. Materials and Methods: The sample included cone-beam computed tomographic (CBCT) records of 30 adult subjects (mean age 30.9 ± 7.0 years) evaluated retrospectively. All CBCT examinations were performed with the i-CAT CBCT scanner. Each exam was converted into DICOM format and processed with OsiriX Medical Imaging software. Proper view sections of the MBS were obtained for quantitative and qualitative evaluation of bone characteristics. Results: Mesial and distal second molar root scan sections showed enough buccal bone for mini-screw insertion. The evaluation of bone depth was performed at 4 and 6 mm buccally to the cementoenamel junction. The mesial root of the mandibular second molar at 4 and 6 mm showed average bone depths of 18.51 mm and 14.14 mm, respectively. The distal root of the mandibular second molar showed average bone depths of 19.91 mm and 16.5 mm, respectively. All sites showed cortical bone depth thickness greater than 2 mm. Conclusions: Specific sites of the MBS offer enough bone quantity and adequate bone quality for mini-screw insertion. The insertion site with the optimal anatomic characteristics is the buccal bone corresponding to the distal root of second molar, with screw insertion 4 mm buccal to the cementoenamel junction. Considering the cortical bone thickness of optimal insertion sites, pre-drilling is always recommended in order to avoid high insertion torque.

31 December 2010 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
STSimona Tecco
Simona Tecco
MSMatteo Saccucci
Matteo Saccucci
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Antonella PolimeniAntonella Polimeni
Antonella Polimeni
MPMario Pagnoni
Mario Pagnoni
GIGiorgio Iannetti
Giorgio Iannetti
There have been no quantitative standards for volumetric and surface measurements of the mandibular condyle in Caucasian population. However, the recently developed cone-beam computed tomography (CBCT) system allows measurement of these parameters with high accuracy.

27 March 2012 in Orthodontics & Craniofacial Research
Verified
Journal Article
Closed access
PDF file
RMR. Martina
R. Martina
ICI. Cioffi
I. Cioffi
MFM. Farella
M. Farella
Pietro LeonePietro Leone
Pietro Leone
PMP. Manzo
P. Manzo
GCG. Cordasco
G. Cordasco

1 May 2008 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
Giovanni MatareseGiovanni Matarese
Giovanni Matarese
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
AMAngela Militi
Angela Militi
MMManuela Mazza
Manuela Mazza
MPMarco Portelli
Marco Portelli
GCGiancarlo Cordasco
Giancarlo Cordasco