Haiwei Zhang

Dr. Haiwei Zhang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2018 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
HZHaiwei Zhang
Haiwei Zhang
AWAiguo Wu
Aiguo Wu
Electromagnetic interference (EMI) has drawn great attention in recent years. In this particular case, it is generated by the three-phase inverters in power electronics applications due to the power devices turning on and off at high frequency. In this paper, in order to alleviate such EMI noise, a high-frequency common-mode (CM) equivalent model is developed, which leverages the effect of parasitic parameters. Meanwhile, in order to eliminate the effect of the parasitic capacitance between the phase node and ground, which is the cause of main CM noise propagation, a coupled inductor connected with a capacitor circuit, which is equivalent to a negative capacitance is proposed. The parameter calculation for the passive negative capacitance circuit is given in detail. The experimental results demonstrated the effectiveness of the circuitry structure and its ability to reduce CM noise.

24 May 2018 in International Journal of Electronics
Verified
Journal Article
Closed access
HZHaiwei Zhang
Haiwei Zhang
AWAiguo Wu
Aiguo Wu
When building single-phase inverter with power Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET), switching action may cause poor reverse recovery characteristic due to body parasitic diode of MOSFET, which can produce peak current in the circuit loop and the high transient voltage and current (dv/dt, di/dt) during the turning-on period. In this article, a novel method to reduce the bridge arm current spike in DC-AC inverter is proposed. The presented method uses the improved and simplified coupled inductor which is connected between the upper and lower power devices. The parasitic capacitors of MOSFET are charged and discharged by the coupled inductor and the energy is released in the new loop; therefore, the bridge peak current is diminished. The time-domain model of transient-state analyses is given in detail. The current spike of the main switch is clamped efficiently. By increasing switching frequency, the volume of the magnetic core can be further reduced which is resulted from reduction in the reverse recovery current in parasitic diode. Because of the suppression of the spike current via the device, the switch-on loss of the power loss is reduced, and low on-state resistor of the power device can be adopted to suppress the conduction loss. The proposed approaches are validated with experimental results.

24 March 2022 in Research Square
Verified
Preprint
Open access
PDF file
HZHaiwei Zhang
Haiwei Zhang
AWAiguo Wu
Aiguo Wu
In this paper, the hybrid compensation loop is introduced to the front end of the load, which can increase the electromagnetic interference current shunt loop, and basically eliminate the common mode noise in the three-phase inverter from the perspective of the interference source. The expressions of the controlled voltage source and the parameter calculations of the shunt path are given in detail. The state of the controlled voltage source is determined by the instantaneous voltage of each phase bridge arm, which has already included the sequence of pulse width modulation, so the common mode noise can be eliminated under different modulation modes. An active method of suppressing common mode (CM) is proposed to regulate the high-frequency CM voltages on the AC buses with respect to the ground. The resultant CM compensation voltages are rendered symmetric to the AC common mode noise, so that load midpoint voltage relative to ground remains constant or zero. The experimental results demonstrated that the common mode voltage can be suppressed by the added compensation circuit effectively under the 2D-SVPWM non-zero vector modulation and 3D-SVPWM non-zero vector modulation. The amplitude, harmonics and frequency of the load voltage isn’t affected by the method of eliminating the common mode voltage.

19 January 2023 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
HZHaiwei Zhang
Haiwei Zhang
AWAiguo Wu
Aiguo Wu
This article comments on the published article titled “Common-mode noise reduction by parasitics capacitance cancellation in the three-phase inverter” authored by Zhang and Wu (2019). The three-terminal electromagnetic interference (EMI) filter can effectively suppress the EMI noise on the output side in the paper. The numerical analysis and the relationship of converting negative inductance into capacitance at high frequency are discussed in detail. Zhang and Wu (2019) presented a parasitic capacitance cancellation method to reduce the conducted emissions exiting a three-phase inverter. The idea of parasitic capacitance cancellation is not novel, and Wang and Lee (2007, 2010) originally applied it to reduce the common mode noise exiting a boost PFC converter. The parasitic capacitance cancellation of inductors is discussed in papers by Neugebauer and Perreault (2006) and Piboonwattanakit and Khan-Ngern (2008). These papers should be cited in the introduction and the references.

27 February 2026 in International Journal of Electronics
Verified
Journal Article
Closed access
HZHaiwei Zhang
Haiwei Zhang
YLYunlong Li
Yunlong Li
1. With the rapid development of power electronics technology, the power electronic devices have been widely utilised in various fields due to their excellent energy-saving features and flexible po...