Cervical cancer is the second leading cause of female-specific cancer-related deaths after breast cancer, especially in developing countries. However, the incidence of the disease may be significantly decreased if the patient is diagnosed in the pre-cancerous lesion stage or earlier. In recent years, computer-based algorithms are widely used in cervical cancer screening. Most of the proposed algorithms follow the procedure of segmentation, feature extraction, and then classification. Nevertheless, few of the existing segmentation methods are as flexible and robust as the human visual system, and the complexity of the algorithms makes it difficult for clinical application. In this study, a computer-assisted analytical approach is proposed to identify the existence of suspicious cells in a whole slide cervical cell image (WSCCI). The main difference between our method and the conventional algorithm is that the image is divided into blocks with certain size instead of segmented cells, which can greatly reduce the computational complexity. Via data analysis, some texture and color histogram features show significant differences between blocks with and without suspicious cells. Therefore these features can be used as the input of the support vector machine classifier. 1100 non-background blocks (110 suspicious blocks) are trained to build a model, while 1040 blocks (491 non-background blocks) from 12 other WSCCIs are tested to verify the feasibility of the algorithm. The experimental results show that the accuracy of our method is about 98.98 %. More importantly, the sensitivity, which is more fatal in cancer screening, is 95.0 % according to the images tested in the study, while the specificity is 99.33 %. The analysis of the algorithm is based on block images, which is different from conventional methods. Although some analysis work should be done in advance, the later processing speed will be greatly enhanced with the establishment of the model. Furthermore, since the algorithm is based on the actual WSCCI, the method will be of directive significance for clinical screening.
Electromagnetic interference (EMI) has drawn great attention in recent years. In this particular case, it is generated by the three-phase inverters in power electronics applications due to the power devices turning on and off at high frequency. In this paper, in order to alleviate such EMI noise, a high-frequency common-mode (CM) equivalent model is developed, which leverages the effect of parasitic parameters. Meanwhile, in order to eliminate the effect of the parasitic capacitance between the phase node and ground, which is the cause of main CM noise propagation, a coupled inductor connected with a capacitor circuit, which is equivalent to a negative capacitance is proposed. The parameter calculation for the passive negative capacitance circuit is given in detail. The experimental results demonstrated the effectiveness of the circuitry structure and its ability to reduce CM noise.
The automatic control device is a critical component of absorption refrigeration systems. Its functional enhancement can reduce operating costs, improve energy efficiency, and ensure long-term stable unit operation. Given that absorption refrigeration systems operate under various dynamic conditions, the rational design of control strategies is particularly important. This study analyzes the influence of changes in the cooling water and heat source water flow rates on the outlet temperature of chilled water in the unit based on the open-loop response characteristics of absorption refrigeration systems. It proposes a dual-loop energy-saving control strategy for single-effect hot water lithium bromide absorption refrigeration systems based on the setpoint comprehensive optimization algorithm. Considering the multiple variables, strong coupling, large inertia, long time delay, and nonlinear characteristics of absorption refrigeration systems, as well as the difficulties in modeling these systems, this study applies a model-free adaptive control algorithm to the system’s control. It derives both SISO and MIMO model-free control algorithms with time-delay components. Through simulations comparing MFAC, improved MFAC, and traditional PID control, the dual-loop energy-saving control strategy is demonstrated to effectively reduce system heat consumption by approximately 20%, decrease power consumption by about 10%, and enhance the system’s SCOP by approximately 19.3%.