Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.
Red blood cells (RBC) deformability enables passage through capillaries, ensuring efficient microcirculatory flow and oxygen transport. Impaired deformability contributes to vascular complications and is associated with conditions such as sickle cell anemia, hereditary spherocytosis, and diabetes. Diamide and glutaraldehyde are commonly used in vitro to simulate pathological rigidity, yet their dose-dependent effects on RBC mechanics remain incompletely characterized. This study investigates the effects of diamide (10-200 μM) and glutaraldehyde (8-159,800 μM) on RBC morphology, deformability and viscosity at 20% hematocrit (HCT). Deformability was assessed by ektacytometry, viscosity by microfluidic viscometry, and morphology by defocusing microscopy with sphericity analysis. Osmolality and HCT were also measured to link the mechanical changes observed. Diamide produced a biphasic response: the maximum elongation index (EIₘₐₓ) decreased up to 140 μM, then partially recovered at higher concentrations. This coincided with increased sphericity, reduced cell volume and surface area, decreased HCT from hemolysis, and a non-monotonous viscosity profile. These effects reflect the combined influence of oxidative stress, vesiculation, and altered cell geometry. In contrast, glutaraldehyde induced an abrupt and irreversible loss of deformability at ≥7990 μM, while morphology and osmolality remained stable. HCT values were consistently lower across concentrations, which we attribute to reduced microtube filling efficiency by rigidified cells. Despite near-zero EIₘₐₓ at high concentrations, viscosity changes were modest due to extreme rigidification. These findings show that viscosity is governed not only by deformability but also by morphology, hemolysis and suspension dynamics.