Andy Vinh Le

Andy Vinh Le

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
TTTatiana Turcitu
Tatiana Turcitu
CACurtis J. K. Armstrong
Curtis J. K. Armstrong
NLNiko Lee-Yow
Niko Lee-Yow
MSMaya Salame
Maya Salame
ALAndy Vinh Le
Andy Vinh Le
MFMarianne Fenech
Marianne Fenech
Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
MFMarianne Fenech
Marianne Fenech
ALAndy Vinh Le
Andy Vinh Le
OGOmemah Gliah
Omemah Gliah
CCCamille Chartrand
Camille Chartrand
In microcirculation, red blood cells (RBCs) tend to migrate toward the centre of the vessel leaving a region of a cell depleted layer or cell-free layer (CFL) at the vessel wall and a core of RBCs at the centre. This heterogenous distribution of cells has an effect on the blood apparent viscosity and the exchanges of gases and nutrients between the RBCs and the vessel. Understanding the formation of the CFL and obtaining accurate measurement of it is paramount for furthering development of devices such as drug administration. This paper presents a general semi-automatic method to quantify the thickness of the CFL for different channel geometries and image quality. It enables the use of a method based on intensity, a method using the gradient of the intensity, or a method based on spatiotemporal variation. The main features are reported, and the performance is demonstrated on different image sets. A pure automatic detection is limited with the most visually correct using the spatiotemporal method, however proposed thresholding through automatic detection allows for quality controls through manual adjustments. With a semi-automatic approach RBC core variability between 3% to 8% was found when the test user was tasked with repeating the analysis of the same set. The presented method provides, users without programming ability with user-friendly interface that can extract CFL automatically with quality control through manual adjustments.