Rafia Inaam

Ms. Rafia Inaam


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
RIRafia Inaam
Rafia Inaam
MBMarcela F. Bolontrade
Marcela F. Bolontrade
SOShunya Okamoto
Shunya Okamoto
TSTakayuki Shibata
Takayuki Shibata
Tuhin SantraTuhin Santra
Tuhin Santra
Moeto NagaiMoeto Nagai
Moeto Nagai
The Polydimethylsiloxane (PDMS) SlipChip is a microfluidic platform enabling fluid manipulation without pumps or valves, simplifying operation and reducing reagent use. High-viscosity silicone oils (e.g., 5000–10,000 cSt) improve sealing but frequently block microfluidic channels, reducing usability. In contrast, low-viscosity oils (50–100 cSt) reduce blockages but may compromise sealing. This study addresses these challenges by optimizing the viscosity of silicone oil and the curing conditions of PDMS. Low-viscosity silicone oil (50 cSt) was identified as optimal, ensuring smooth slipping and reliable sealing without blockages. Curing conditions were also adjusted to balance adhesion and stiffness as follows: lower temperatures (50–60 °C) enhanced van der Waals adhesion, while higher temperatures (80 °C) increased stiffness. A mixed curing approach (80 °C for the top layer and 60 °C for the bottom layer) further improved performance. Biocompatibility testing using human osteosarcoma cells demonstrated minimal cytotoxicity with 50 cSt oil, supporting cell viability (95%) comparable to traditional multiwell plates. These findings provide practical guidelines for fabricating reliable and biocompatible SlipChips.

31 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
AMAniket Mishra
Aniket Mishra
RIRafia Inaam
Rafia Inaam
SOShunya Okamoto
Shunya Okamoto
TSTakayuki Shibata
Takayuki Shibata
Tuhin SantraTuhin Santra
Tuhin Santra
Moeto NagaiMoeto Nagai
Moeto Nagai
A new generation of nanoscale photosensitizer agents has improved photothermal capabilities, which has increased the impact of photothermal treatments (PTTs) in cancer therapy. Gold nanostars (GNS) are promising for more efficient and less invasive PTTs than gold nanoparticles. However, the combination of GNS and visible pulsed lasers remains unexplored. This article reports the use of a 532 nm nanosecond pulse laser and polyvinylpyrrolidone (PVP)-capped GNS to kill cancer cells with location-specific exposure. Biocompatible GNS were synthesized via a simple method and were characterized under FESEM, UV–visible spectroscopy, XRD analysis, and particle size analysis. GNS were incubated over a layer of cancer cells that were grown in a glass Petri dish. A nanosecond pulsed laser was irradiated on the cell layer, and cell death was verified via propidium iodide (PI) staining. We assessed the effectiveness of single-pulse spot irradiation and multiple-pulse laser scanning irradiation in inducing cell death. Since the site of cell killing can be accurately chosen with a nanosecond pulse laser, this technique will help minimize damage to the cells around the target cells.

21 March 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RIRafia Inaam
Rafia Inaam
MD HUSSAIN MOHAMMAD IMRANMD HUSSAIN MOHAMMAD IMRAN
MD HUSSAIN MOHAMMAD IMRAN
HYHirofumi Yamamoto
Hirofumi Yamamoto
MBMarcela F. Bolontrade
Marcela F. Bolontrade
SOShunya Okamoto
Shunya Okamoto
Moeto NagaiMoeto Nagai
Moeto Nagai
PDMS SlipChips are vital for precision medicine, but their performance often degrades when solutions leak or air pockets become trapped between layers. These failures stem from the inherent stickiness of PDMS and uneven surface contact, as the sliding nature of the device prevents permanent sealing. This work addresses these technical hurdles by integrating magnetic clamping with oil-infused lubrication and refined microwell geometries. A 3D-printed magnetic fixture maintains steady contact pressure during operation, while custom-made microstages provide the precise control needed to align microwells across the x–y plane. By allowing the porous PDMS to absorb silicone oil, we created a stable lubricating interface that prevents leakage and reduces friction without sacrificing mobility. We found that a microwell-to-channel width ratio of five substantially suppresses bubble formation compared with narrower designs. These enhancements ensure the generation of consistent, discrete concentration gradients and establish a reliable platform for high-throughput assays using minute sample volumes.